Programming the Device on the GC2/GC3 Panel

For GC2 and GC3 panels, program the Stove & Grill Guard on your 
2GIG panel with the following parameters.  (Please refer to your 
panel’s quick programming guide for the actual steps.)
Sensor Type: 

(23) No Response Type

Sensor Equipment Type:  Contact 
Equipment Code: 

(0862) 2GIG Thin Door/Window Contact

1

Serial Number: 

[Input the unique 7-digit TXID.]

2

Equipment Age: 

New

Sensor Loop Number: 

2

Dialer/Transmission Delay:  Enabled
Voice Descriptor: 

GAS LEFT ON

3

Sensor Reports: 

Enabled

Sensor Supervised:

 

Disabled

Sensor Chime: 

[User-speci

fi

 ed]

This is a provisional Equipment Code.  A new category called 

“Stove & Grill Guard” (or similar name) will be added in a future 
GC2/GC3 panel update.

Alterna  vely, a Stove & Grill Guard can be automa  cally learned in.

This is a recommended voice descriptor.  The user may de

fi

 ne a 

custom voice descriptor, as needed.

Programming the Device on the Vario Panel

For the Vario panel, a  er learning in

1

 the Stove & Grill Guard, please

con

fi

 gure the zone the Stove & Grill Guard is in with the following

parameters:
Zone Type:   

Output Trigger

Zone Sound Armed Away:  Silent
Zone Sound Armed Stay:  Silent
Zone Sound Disarmed:  Chime or Silent

1

Alterna  vely, you can use the Vario TXID to manually enroll the 

device.

Programming the Device on the Honeywell Vista Panel

For the Honeywell Vista panel, 

fi

 rst enroll the Stove & Grill Guard 

into the panel as follows:

 

For Panel 15P, 20P or 50P, auto-enroll the device into the panel.  
The LED will 

fl

 ash 6   mes to con

fi

 rm the enrollment.

 

For Panel 10SE or 20SE, set the address to "00", then auto-enroll.  
The LED will be solid green to con

fi

 rm the enrollment.

Then program the panel as follows:
1.  Enter [4-digit installer code], then [800], then [*56].  When the 

screen displays "Set to Con

fi

 rm?" press [*] bu  on.

2.  When prompted by the screen to "Enter ZN Num" input a 

chosen zone number (ZN) between 09 and 48, then press [*] 
bu  on.

3.  Type in the ZN to display the current zone summary on the 

screen.

4.  Enter the following parameters:

 

ZT (zone type): [10]

 

P (par    on): [1]

 

RC (report code): [01] then [0010]

 

IN (input device type): [RF Trans. 3]

 

Transmi  er Serial Number: [A] then [7-digit TXID]

 

Loop Number: [2]

5. Con

fi

 rm the zone summary displays the parameters correctly.

Setting up E-mail Notification – Alarm.com Accounts Only

1. Navigate to 

h

Ʃ

 p://www.alarm.com

 and click 

LOGIN

.

2.  Your systems dashboard page will appear. Select the Security tab 

and click Sensors.

3. Iden  fy the new sensor you added. You can rename the

Sensor Name. When 

fi

 nished, click 

Save

.

4. Click the 

No

Ɵ

 

fi

 ca

Ɵ

 ons

 tab, and then 

+New No

Ɵ

 

fi

 ca

Ɵ

 on

bu  on to create a new event. The menu will appear with
the 

Standard

 tab open by default.

5. Click 

Sensor Le

Ō

  Open

. Add parameters. Also, click 

+Add 

Recipient 

to add recipients associated with the no  

fi

 ca  on.

6. Click 

Close 

when names have been selected, then click 

Save 

No

Ɵ

 

fi

 ca

Ɵ

 on

.

Specifi cations

•  Signal Range: 100   . open-air from a 2GIG panel
•  Transmission Frequency: 345 MHz
•  Disc dimensions: 2.2” diameter, 0.21” thickness
• Opera  ng Temperature: 14°F to 167°F (-10°C to 75°C)
• Ba  ery Life: Up to 5 years

FCC & IC Notice

This device complies with Part 15 of the FCC Rules and Industry Canada license 
exempt standard(s). Opera  on is subject to the following two condi  ons:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference 
received that may cause undesired opera  on.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables 

aux appareils radio exempts de licence. L’exploita  on est autorisée aux deux 

condi  ons suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’u  lisateur de l’appareil doit accepter tout brouillage radioélectrique subi, 

même si le brouillage est suscep  ble d’en comprome  re le fonc  onnement.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du 

Canada.
This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed 

to provide reasonable protec  on against harmful interference in a residen  al 

installa  on.
This equipment generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instruc  ons may cause harmful 

interference to radio communica  ons. However, there is no guarantee that 
interference will not occur in a par  cular installa  on. If this equipment does 
cause harmful interference to radio or television recep  on, which can be 

determined by turning the equipment o

  and on, the user is encouraged to try 

to correct the interference by one or more of the following measures:
•  Reorient or relocate the receiving antenna
•  Increase the separa  on between the equipment and receiver
•  Connect the equipment into an outlet on a circuit di

 erent from that to 

which the receiver is connected

•  Consult the dealer or an experienced radio/TV technician to help

WARNINGS:

•  Changes or modi

fi

 ca  ons not expressly approved by the manufacturer could 

void the user’s authority to operate the equipment.

•  The Stove & Grill Guard is not intended as a life-safety device. It is not 

intended to replace any other safety considera  ons.

Limited Warranty

This Nortek Security & Control product is warranted against defects in material 

and workmanship for 12 months. Nortek Security & Control does not warrant 
this product to consumers.
There are no obliga  ons or liabili  es on the part of Nortek Security & Control 

for consequen  al damages arising out of or in connec  on with use or 
performance of this product or other indirect damages with respect to loss of 
property, revenue, or pro

fi

 t, or cost of removal, installa  on, or reinstalla  on. 

All implied warran  es for func  onality, are valid only un  l the warranty expires. 
This Nortek Security & Control LLC Warranty is in lieu of all other warran  es 

expressed or implied.

For technical support in the USA and Canada:

800.421.1587
Email: [email protected]
Visit www.nortekcontrol.com for technical support hours of opera  on

For technical support outside of the USA and Canada:

Contact your regional distributor
Visit dealer.2gig.com for a list of distributors in your region

Patent Pending.
2GIG® is a registered trademark of Nortek Security & Control LLC.

10017336A X2

Отзывы: