background image

7

11.5 How to set the  monitor panel on 

In default mode,when receive a calling,the master and slave monitors will ring at the same 
time,and just the master monitor can display the image while the slave monitors can not.
But the settings can be changed,you can set the master monitor and all the slave monitors 
to panel on at the same time when receiving a call, just input the code number of 8006  on 
each slave monitor.











The unlock time can be changed by yourself at any time.it can be set from 1 to 9 seconds.
The code number from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds.

Unlock time:

11.6 How to set the unlock parameter

There are two unlock modes: 1.power-on- to-unlock type:unlock mode=0(by default) 
                                                        2.power-off-to-unlock type:unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1

Unlock mode:

11.4 How to set the slave monitor address

Maximum 4 monitors can be connected in one apartment,one master monitor together 
with 3 slave monitors, so you should set the address correctly.(note:must have one 
monitor to be set as master monitor)
The code of 8000 is used to set the master monitor.
The code of 8001 is used to set the  first slave monitor .
The code of 8002 is used to set the  second slave monitor .
The code of 8003 is used to set the  third slave monitor .

Содержание DT43

Страница 1: ...DT43 D4 USER MANUAL EN 2 Wire Video Intercom System Read this manual carefully before using the product and keep it well for future use ...

Страница 2: ... RING GND NC 3 ON L1 L2 DIP 4 5 6 SW SW Door bell call button connection port Ring GND Extra buzzer connection port NC Reserved L1 L2 Bus terminal DIP switches Total 6 bits can be configured Bit1 Bit5 Used to User Code setting Bit6 Set to ON if the monitor is at the end of the line or works with DBC4A Otherwise set to OFF Terminal Description 1 2 sw sw RING GND NC 3 ON L1 L2 DIP 4 5 6 1 2 SW SW RI...

Страница 3: ...tor is in standby mode press Talk Mon Button or select Monitor By Select button on main menu press Menu Button to confirm and then it will enter the select a camera page then you can use Button to select the camera you want the screen can display the view of outside 2 1 Use the screws to fix the Mounting Bracket on the mounting box fitting accesories includes a Bracket Two pieces of 4X25 screws ar...

Страница 4: ...nward to select Intercom Call item press Menu Button to enter the select intercom page you have 3 items to select Use button to selete Intercom Call item then press Menu button to confirm Use Button to selete Namelist Call item then press Menu button to confirm Use Button to selete the item you want then press Menu button to call Calling Namelist Call Select Intercom Inner Call Call Guard Unit 01 ...

Страница 5: ...nd in 30 seconds will be transfer to the number you set Even though the monitor will shut off when transfer via TPC GSM TPS you still available to operate it such as monitor talk and unlock 3 Simutaneously Calls from outdoor station will be diverted to your telephone immediately At this mode the monitor won t shut off when TPC GSM TPS divert sucessfully but if the monitor answers the call at this ...

Страница 6: ...the language 8 Light Function 9 Setup Function When the monitor is in standby mode press Menu Button to enter main menu page Use Button to move upward downward to select Light item press Menu Button to enter the light Option page you have 3 items to select When the monitor is in standby mode press Menu Button to enter main menu page Use Button to move upward downward to select Setup item press Men...

Страница 7: ...tton to enter the restore page and then press Menu Button to confirm 11 Monitor Parameter Setting 11 1 How to enter the installation setting page H W a1 1 About Addr 00 00 Video STD AUTO S W 00 01 00 0000 Installer Setup A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started The code number of 8004 is used to set t...

Страница 8: ...o 1 9 seconds Unlock time 11 6 How to set the unlock parameter There are two unlock modes 1 power on to unlock type unlock mode 0 by default 2 power off to unlock type unlock mode 1 The code number of 8010 is used to set the unlock mode to 0 The code number of 8011 is used to set the unlock mode to 1 Unlock mode 11 4 How to set the slave monitor address Maximum 4 monitors can be connected in one a...

Страница 9: ...nitor Bit 1 to Bit 5 are used to User Code setting The value is from 1 to 32 which have 32 different codes for 32 apartments Bit 6 is line terminal switch which have to be set to ON if the Monitor is in the end of the line bus otherwise set to OFF The end of the line is terminal that no other section will start from it 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2 3 4 5 6 ON DIP 1 2...

Страница 10: ... ring tone and talking volume adjustment 9 13 Screen and Volume Adjustment During monitoring or talking press Menu Button theADJUST MENU will be displayed Use Menu Button to select the adjustment item use Button to decrease increase the value press Return Button to quit the adjust page Bright 5 12 Basic Connection door station BUS IM BUS DS PC6 AC Doorbell Button Switch 1 2 sw sw RING GND NC 3 ON ...

Страница 11: ...mption Standby 0 17W Working status 4 7W Monitor screen 4 3 inch digital color TFT Display Resolutions 380 R G B x 272 pixels Video signal 1Vp p 75Ω CCIR standard Wiring 2 wires non polarity Monitor time 40 seconds Talking time 90 seconds Dimensions 137 H 137 W 17 D mm 10 ...

Страница 12: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG 43 D4 V1 ...

Отзывы: