DT - System - Technical Guide
40
What's Slave Address
2 -wire DT system is capable of connecting up to 4 Monitors in one apartment, which means they will have the same
User Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below:
• 1. All the Monitors of same apartment must be programmed with the same User Code on the DIP switches.
• 2. There is only one master Monitor in the one aparment, and the Slave Address of the master Monitor is set to 0.
Each Slave Monitor should be set from 1~3.
• By default, Monitor’s Slave Address is pre -set to 0(master Monitor).
• When Door Station calls, only the master Monitor will turn on the screen, the slave Monitor will only ring.
Slave Address
1
Slave Address
0
Master Monitor
Slave Monitor 1
Slave Monitor 2
Slave Monitor 3
Slave Address
2
Slave Address
3
Please note, when called by Door Station, all Monitors will ring, however, only the Monitor which Sub User Code was
programmed to 0 will turn on the screen.
Programming Slave User Code is by means of Monitor Menu, in the Main - -> Setup - -> Advance Set page(a password
will be required before enter the setting, the password is:
2008
), operate as below:
H o m e I n t e l l ig e n t S y s t e m
Other settings...
Informations...
Slave Addr Set -- 0
Guard Unit Set -- 0
Date and Time set...
Exit
• The Slave Addr Set item is for the master and slave
user code setting, default is set to 0 for master user
code. It can be change to 1, 2 or 3.
• The Guard Unit Set item is for Guard Unit Monitor
setting, the default it set to 0, if set to 1, this Monitor is
become a Guard Unit Monitor.
Содержание DT 2-wire
Страница 1: ...DT 2 wire Video Intercom System Technical Guide ...
Страница 6: ...3 ...
Страница 23: ...DT System Technical Guide 20 DIN Installation 85 260AC DPS DIN nail PS5 ...
Страница 29: ...DT System Technical Guide 26 Dimensions 90mm 175 mm 60 mm 80mm Direct Wall Mounting DIN Rail Mounting ...
Страница 30: ...27 ...
Страница 53: ...DT Technical Manual 090909 ...