background image

EN

4

straight out, never remove the plug by pulling on the cord. 

2.2.14

 Keep the heater far from curtain or places where the 

air inlet can easily be blocked.

2.2.15 

The power coupler is waterproof when not in use. In 

order to prevent possible electric shock or leakage current 

,never use the appliance with wet hand or operate the 

appliance when there is water on the power cord.

2.2.16

 Do not dispose of electrical appliances as unsorted 

municipal waste, use separate collection facilities. Contact 

you local government for information regarding the 

collection systems available. If electrical appliance are 

disposed of in landfills or dumps, hazardous substances 

can leak into the groundwater and get into the food chain, 

damaging your health and well-being.

3. Introduction

3.1

 It incorporates a thermostat and a self-resetting thermal 

cut-out to control the heating elements. The thermostat 

feels the air temperature and controls the surrounding 

temperature. The fan motor is controlled by thermostat and 

it stops when the thermostat cuts off the heating element. 

The self-resetting thermal cut-out will switch off the heater 

to ensure the safety when overheating.

Содержание 2E-AHC2000

Страница 1: ...INDUSTRIAL FAN HEATER User Manual Model 2E AHC2000 2E AHC3000 EN RU UA...

Страница 2: ...not play with the device Cleaning and maintenance by the consumer should not be carried out by children without supervision 1 2 WARNING To prevent overheating it is forbidden to cover the heater 1 3 C...

Страница 3: ...evice on 2 2 6 The fan heater must not be placed in rooms where flammable liquids or gases are used or stored 2 2 7 If an extension cord is used it must be as short as possible and always be fully ext...

Страница 4: ...ilities Contact you local government for information regarding the collection systems available If electrical appliance are disposed of in landfills or dumps hazardous substances can leak into the gro...

Страница 5: ...stat and it stops when the thermostat cuts off the h self resetting thermal cut out will switch off the heater to e when overheating 3 Technical specifications Model 2E AHC2000 Voltage 220 240 V requi...

Страница 6: ...urn the thermostat to MIN position and turn the switch to fan position let the appliance cool down for two minutes then turn off the heater and pull out the plug 7 Cleaning and Maintenance 7 1 Before...

Страница 7: ...e label The air inlet grill is blocked Keep the heater far way from articles like curtain plastic bag paper and other things which can cover the inlet or can be easily cover on the air inlet The appli...

Страница 8: ...minimum heat output elmin N A kW Single stage heat output and no room temperature control no In standby mode elSB N A W Two or more manual stages no room temperature control no With mechanic thermost...

Страница 9: ...minimum heat output elmin N A kW Single stage heat output and no room temperature control no In standby mode elSB N A W Two or more manual stages no room temperature control no With mechanic thermost...

Страница 10: ...isposal Environmental Protection Waste electrical production should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycl...

Страница 11: ...11 UA 1 1 8 1 2 1 3 3 1 4 3 8 3 8...

Страница 12: ...12 UA 1 5 2 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 2 6 2 2 7 2 2 8 2 2 9 2 2 10...

Страница 13: ...13 UA 2 2 11 2 2 12 2 2 13 2 2 14 2 2 15 2 2 16 3 3 1...

Страница 14: ...ostat cuts off the he self resetting thermal cut out will switch off the heater to e when overheating 3 Technical specifications Model 2E AHC2000 Voltage 220 240 V required power 2000 W Frequency 50 H...

Страница 15: ...15 UA 6 6 1 6 2 6 3 MAX 6 4 6 5 6 6 MIN 7 7 1 50 C 7 2 7 3...

Страница 16: ...16 UA 8 10...

Страница 17: ...17 UA 2E AHC2000 Pnom 2 Pmin 1 0 Pmax 2 elmax elmin elSB s...

Страница 18: ...18 UA 2E AHC3000 Pnom 3 Pmin 1 5 Pmax 3 elmax elmin elSB s...

Страница 19: ...19 UA...

Страница 20: ...RU 20 1 1 8 1 2 1 3 3 1 4 3 8 3 8...

Страница 21: ...RU 21 1 5 2 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 2 6 2 2 7 2 2 8 2 2 9 2 2 10...

Страница 22: ...RU 22 2 2 11 2 2 12 2 2 13 2 2 14 2 2 15 2 2 16 3 3 1 19...

Страница 23: ...quired power 2000 W Frequency 50 Hz current 8 3 9 1 A Setting 1000 2000 W Self resetting Thermostat 68 C Heating area 20 m2 Air output 197 m3 h Product meas mm 210x160x217 N W KG 1 55 3 1 Housing of s...

Страница 24: ...RU 24 6 6 1 6 2 6 3 MAX 6 4 6 5 6 6 MIN 7 7 1 50 C 7 2 7 3...

Страница 25: ...RU 25 8 10...

Страница 26: ...RU 26 2E AHC2000 Pnom 2 Pmin 1 0 Pmax 2 elmax elmin elSB s...

Страница 27: ...RU 27 2E AHC3000 Pnom 3 Pmin 1 5 Pmax 3 elmax elmin elSB s...

Страница 28: ...28 RU 28...

Страница 29: ...maged or altered and no stamp of the sales store on the warranty the warranty service may be not be provided Damage causes by use beyond the normal range of use is not covered by the warranty service...

Страница 30: ...30 30 UA 24 18 04073 0 800 300 345 044 230 34 84 390 55 12 www erc ua service...

Страница 31: ...RU 31 24 18 04073 0 800 300 345 044 230 34 84 390 55 12 www erc ua service...

Страница 32: ......

Отзывы: