background image

Normal Operation 

In order to activate normal operation the User must simply remove the WTS from an active charger. After 

5 to 10 seconds, the WTS will exit charge mode and enter normal operation. Using the mobile application 

the User is able to view the operational transition of the device as the temperature reading will be displayed. 

The temperature reading displayed to the User will periodically update with the temperature data recorded  

of the surface in front of the infrared temperature sensor. 

 

The WTS may be held in place on a surface using tape or fabric as long as it does not hinder the 

WTS ability to transmit data wirelessly.   

 

 

FCC Notification 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures: 

 

• 

Reorient or relocate the equipment being interfered with. 

• 

Increase the separation between the charger and the equipment subject to interference. 

• 

Connect the equipment into an outlet on a circuit different from that to which the charger is 

connected. 

• 

Consult the dealer or an experienced radio/TV/electronics technician for help. 

CAUTION: Changes or modifications to this unit not expressly approved by the party responsible for 

compliance could void the user’s authority to operate the equipment. 

RF Exposure Notice 

Gorilla Horse Sensor has been evaluated to meet general RF exposure requirement. This device can be 

used in portable exposure condition without restriction. 

 

Содержание 28-0010038

Страница 1: ...ional mode is charging where the device is not performing temperature measurements and is focused on charging the internal battery While the WTS is charging it will limit wirelessly accessible data to the state of charge of the battery and charge status This is reflected in the mobile application where the user is able to see the status of the battery while temperature information is removed from ...

Страница 2: ...s of the wireless charging station If the WTS is not flat when placed onto the wireless charging station the user must remove the WTS and replace the WTS within the wireless charging station correctly in order for the WTS to charge If a WTS is not positioned correctly within the wireless charging station it will not charge Charging Notes First time charge may take up to 24 hours It is recommended ...

Страница 3: ...adiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is en...

Страница 4: ...5 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Responsible Party in the USA 28 Gorilla LLC 12 S San Marco Pl Chandler AZ 85255 ...

Отзывы: