                                                                      Setting                                                                                                                                    

2. Press and hold the button within first 2 

seconds until °C or °F change, release the 
button as soon as change occurs.

3. Press and hold the button again for 2 

seconds to switch back and forth from °C or 
°F. 

                                                          Memory  Function                                                                                                                                    

Recall Memor y

1. When the unit is off, press and hold the power 

button around 3 seconds until the last memory 
shows.

2. You may continue to press and release the 

power button to recall up to 9 previous records. 

3. Discontinue pressing the power button to stop 

recalling memories.

4. The memory will flash for times then the 

device is ready to do a new measurement.

Delete All Memor y

When the device is in memory mode, press and 

hold the power button to delete all memories, 

then the device will be off automatically.

Otherwise,

1. To stop deleting memories, do not press the power button when 

you see "dEL". 

2. Then the device will return to memory mode after 2 seconds then it 

is ready for measurement.

Delete memory

Power Off

Please read thoroughly before using.

Warning and Caution

YYMM : Lot Number composed by year(Y) and 
month(M) of manufacture.

                                                    Battery  Installation                                                                                                          

WARNING

Use only same type of alkaline batteries to avoid incompatibility.

1. Replace with 2 new AAA batteries simultaneously when the low 

battery indication appears. 

2. Remove batteries if the device is not likely to be used for a long 

period of time.

3. Do not dispose the batteries in a fire, the batteries will explode.

Replace Battey

1. Remove the battery cover to insert batteries.

2. Confirm the polarity (+ and -) of batteries are correct as indicated 

inside the compartment and insert batteries accordingly. 

3. Replace the battery cover. 

                                                                      Setting                                                                                                                                    

Setting °C or °F Scale

1. Turn on the device by pressing and release the button.

Содержание KI-8130

Страница 1: ...planation of Symbols 4 Battery Installation 5 Setting 5 Memory Function 6 Use 7 Cleaning Disinfection 8 Care and Storage 9 Product Specification 10 Trouble Shooting 11 FCC Statement 11 Limited Warranty 12 Lot Number information 12 Table of Contents INSTRUCTION MANUAL Distributed by 180 INNOVATIONS LAKEWOOD CO 80215 Manufactured by K jump Health Co Ltd Made in China www 180innovations com ...

Страница 2: ...frared from human body to detect your temperature It can be used with adult or pediatric patients and it can be used in household Safety Instruction WARNINGS 1 Read the entire instruction manual before trying to operate the device 2 The device is delivered non sterile please clean the device before measuring 3 Stop using the device if malfunctions appear or if it operates abnormally 4 Children sho...

Страница 3: ...icated 1 Place the probe in scarred tissue or tissue compromised by any disorders of measuring site 2 Patients in trauma or treat with certain drug therapies of measuring site Device Overview Display Overview Quick Start 1 Install batteries into the device Make sure the polarity and of the battery matches as shown in the battery compartment 2 Press and release the power button you will hear a shor...

Страница 4: ...e 1 To stop deleting memories do not press the power button when you see dEL 2 Then the device will return to memory mode after 2 seconds then it is ready for measurement Delete memory Power Off Please read thoroughly before using Warning and Caution YYMM Lot Number composed by year Y and month M of manufacture Battery Installation WARNING Use only same type of alkaline batteries to avoid incompat...

Страница 5: ...n accordance with the temperature shown as below table Temperature T Backlight T 98 9 Green Backlight 99 T 99 4 Yellow Backlight 99 5 T Red Backlight Cleaning Disinfection 1 To clean and disinfect the device use a cotton swab or pad moistened with 70 alcohol to wipe the Sensor and Probe 2 Use a cloth dampened with water or neutral detergent to clean and dry the device 3 Do not use thinner benzene ...

Страница 6: ... the device in an extreme environment with direct sunlight high low temperatures or in a location with high humidity or severe dust Please contact your local agents or distributors if the device does not function properly as specified under Product Specification Product Specification Product Specification Measuring site Ear canal Measuring times 3 seconds Measuring range 90 F 110 F 32 2 C 43 3 C A...

Страница 7: ...g measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help REV 20171206 PN 828130XXXX Changes or modifications not expressly approved by the party responsible for compliance c...

Отзывы: