4.2 Maintaining the O-ring Seal   

 

If the main body to lid O-rings are not installed, install the 

O-rings before diving. Their care and maintenance are critical 

to the watertight integrity of the housing. If the O-rings are 

contaminated, or not already installed; inspect, grease and 

install the O-rings according to the following guidelines.

   

 

4.3 Inspection, cleaning and re-instillation of the O-rings 

 

Tools 

 

 

A soft cotton bud or sponge applicator, make sure these are free of all 

contamination such as loose fibers and 

sand, the tube of silicone grease supplied with the housing. 

Note other types of silicone grease specifically for 

use with underwater camera equipment

 

can usually also be used. It is advised to carry out the following 

procedure on a firm clean

 

level surface, (e.g. at a table), to prevent skidding especially when diving from

 

boat. 

 

When to maintain the O-ring seal   

 

Remove the O-ring periodically for inspection. It is not necessary to remove, clean and re-install the O-ring 

after every dive provided the O-rings are not become contaminated. As a rule of thumbs

set up the camera 

and housing before a day¡s diving. If the housing is required to be opened between dives for changing 

memory card or re-charging batteries, make sure the outside of the housing is thoroughly toweled dry 

before opening up. After removing the lid and servicing the camera, replace the lid straight away, rather 

than leaving it lying around. Before replacing the lid, check the o-rings and make sure that no 

contamination such as dust, hair, salt, sand etc. has fallen onto the O-ring or O-ring recess, as a precaution 

we recommend to inspect the O-ring every time the lid is opened and to carry out the maintenance only if 

necessary.   

 

Procedure 

 

The O-ring can be extracted using an O-ring extractor tool (make sure the tool as no sharp edges). 
Alternatively use the flats of the thumbs to gently stretch the O-ring on two faces thus making a small loop 
protruding a few mm. The loop can then be grasped between finger and thumb, to pull the O-ring over the 
lip. Clean the O-ring recess (the square groove where the O-ring sits) with a cotton bud.   
Inspect the O-ring all the way round its surface for damage such as cuts

tears or contamination. This 

should be done visually and also by feeling the surface 
texture between finger and thumb. 
           

IF THE O-RING IS DAMAGED OR SUSPECTED 
OF BEING DAMAGED, DISCARD

 IT 

IMMEDIATELY

.   

spare O-ring is supplied with your housing, or a 

replacement O-ring can be ordered from 10BAR. If the 
O-ring is contaminated or suspected of being 
contaminated, clean it with an optical cleansing cloth that 
is free of loose fabric or contamination. After cleaning 
inspect the O-ring again. 

 

Содержание LUMIX LX3

Страница 1: ...or closure the double o rings and key hole lock design provide ease of use and added security Now you can use small cameras with the feel and function of professional housings 2 Specifications Test Pressure Housings individually tested to 10 Bar 90 m 300 ft Recommended working pressure 60 m Closure Design Double O rings Key hole Lock Body Material 6061 Aluminum Acrylic Overall Size 134 x 152 x 112...

Страница 2: ...3 BULKHEAD 14 LOCKING LEVER 15 HOUSING BODY 16 HOUSING LID 17 PORT 3 2 Control Details 1 FLASH ON align the white dot towards the lid press down and turn towards the lighting logo the flash should pop up 2 FLASH OFF turn the Flash On white dot towards the lid turn the button to wards the no lighting logo Make sure that the Flash is turn off before opening the lid 3 FOCUS press to activate confirm ...

Страница 3: ...tegrity Each housing is individually inspected and hydrostatically tested in the factory The design of the main piston O ring seal is among the most reliable in the industry and the watertight integrity is excellent This special O ring design provides a perfect seal even if there is any movement between the body and lid due to change of ambient pressure However please note that responsibility for ...

Страница 4: ... the outside of the housing is thoroughly toweled dry before opening up After removing the lid and servicing the camera replace the lid straight away rather than leaving it lying around Before replacing the lid check the o rings and make sure that no contamination such as dust hair salt sand etc has fallen onto the O ring or O ring recess as a precaution we recommend to inspect the O ring every ti...

Страница 5: ...he Key hole Lock is simple and easy to use and adding security To open the housing make sure that the flash on the camera has been turned off before opening the lid Turn the levers of the lock perpendicular to the wall of the housing until the lock is released on both sides Pull out the lid by holding on the grip near the lock To close the housing place the lid over the housing and align the key h...

Страница 6: ...the side wall of the housing Lock the lid by press down the lever and turn until the lever is parallel to the side wall of the housing After replacing and locking the lid make a final visual inspection of the main O ring for contamination Note If the O ring is in good contact a thin black line about 0 5 to 1mm in width should be visible where the O ring is in contact with the lid Follow this line ...

Страница 7: ...ad if no sync cord is connected 5 Use Care of Housing 5 1 Pre Dive Function Check Just before entering the water make a habit of reviewing the proper steps to close the housing and connect the bulkhead Make a visual check of the O ring seal It is also useful to switch on the camera and check that controls e g on off zoom shutter functions operate normally Check housing is closed Check O ring is in...

Страница 8: ...sand After a series of 10 or more dives e g after a dive holiday it is recommended to immerse the housing for 2 3 hours in warm water to dissolve any salt deposits that may have built up No chemical cleaners should be used Important For long term storage please remove the main closure o rings from body 5 4 Transportation Please protect the housing during transportation It is recommended to remove ...

Страница 9: ... the information below and return a copy to 10Bar Underwater Housing at the address below to validate the warranty Copy to be retained by user Housing Type Date of Purchase Serial Number Labeled inside housing Dealer Owner s Name e mail Owner s Address Tel Fax Office Showroom Unit C 2 F Wing Hin Factory Building 31 33 Ng Fong St San Po Kong Hong Kong Tel 852 2573 3228 Fax 852 2811 9180 Email servi...

Отзывы: