background image

 

                                                                                                                                                                 

Zolix Instruments Co., Ltd.

   

  http://www.zolix.com.cn    E-mail: [email protected]

 

 

 

 

 

Omni-λ200i series Grating Monochromator 

and imaging spectrograph 

Version 1.0    2017.8

 

Operation Manual 

 

 

 

 

 

 

 

 

 

                                                                         

       

  Zolix Instruments Co., Ltd. 

 

 

 

Summary of Contents for Omni-l200i Series

Page 1: ...Zolix Instruments Co Ltd http www zolix com cn E mail info zolix com cn Omni 200i series Grating Monochromator and imaging spectrograph Version 1 0 2017 8 Operation Manual Zolix Instruments Co Ltd...

Page 2: ...ww zolix com cn E mail info zolix com cn Security Considerations The Monochromator contains delicate optics Do not open the monochromator lid if not needed Do not tough or breathe over gratings Never...

Page 3: ...1 2 Omni 200i Optical System Introduction 2 3 Main technical specifications 3 4 Configurations 4 5 Installation and Operation 6 5 1 Installation 6 5 1 1 USB Software Installatio 6 5 1 2 Connecting the...

Page 4: ...slit control and filter selection Image astigmatism correction Optimised toroidal optics for high density multi track capabilities For imaging spectrograph A USB 2 0 interface giving the user the bene...

Page 5: ...ments Co Ltd http www zolix com cn E mail info zolix com cn 2 Omni 200i Optical System Introduction Side Entrance Slit Entrance Mirror Collimating Mirror Focusing Mirror Exit Mirror Side Exit Slit CCD...

Page 6: ...ion nm CCD 26um 0 28 Reciprocal Linear nm mm 3 6 Wavelength Accuracy nm 0 2 Wavelength Repeatability nm 0 1 Minim Step nm 0 01 Stray light 1 10 5 Focal Area mm 30 w 14 h Optical axis height mm 146 Sli...

Page 7: ...it 1b Front Exit Slit 3 Power Switch 4 Power Socket DC24V input connect to Zolix power adaptor Y CAD120241 5 Power Indicator Light A flashing indicates that the system is online and the green light in...

Page 8: ...Configurations 5 Zolix Instruments Co Ltd http www zolix com cn E mail info zolix com cn 10 Slit aperture 14mm 4mm 2mm 10...

Page 9: ...graph at this stage 3 Connect the other end of the USB cable to the PC and plug in the power supply to the mains but do not switch the power on 4 Put the CD into the PC CD ROM switch the power on to t...

Page 10: ...Deuterium Multiplex Tungsten Halogen and Xenon light source e Fitting the detector to the output slit we can supply Photomultiplier Silicon Series Detectors InGaAs Series Detectors and so on f Open t...

Page 11: ...of the monochromator The slit width of each bilateral slit assembly is adjustable from 0 010 millimeters to 3 millimeters 10 m to 3 000 m by a micrometer located on the top of the slit housing For ma...

Page 12: ...12 0 6 473 150 31 89 0 to 9600 2 24 1 2 956 The reference wavelength of the 3600 grating gratings in the table is 253 65nm and the reference wavelength of the rest of the grating gratings is 435 833nm...

Page 13: ...uments Co Ltd http www zolix com cn E mail info zolix com cn A dialog box similar to the following should appear Type 15 in the Decimal click on Set Output shutter will be open Type 0 in the Decimal c...

Page 14: ...Installation and Operation 11 Zolix Instruments Co Ltd http www zolix com cn E mail info zolix com cn...

Page 15: ...shutter in the spectrograph can be set by EmenTool software also First click on the button as below Then a dialog box similar to the following should appear click on Shutter And then the shutter contr...

Page 16: ...Installation and Operation 13 Zolix Instruments Co Ltd http www zolix com cn E mail info zolix com cn...

Page 17: ...rsion of different spectrograph are shown in the SPECIFICATION table and the Reciprocal Dispersion value only for 1200g mm gratings So you need the below formula to calculate other groove density grat...

Page 18: ...0 500 50 50 9 120 250 NP 200 500 1200 250 50 50 9 120 300 NP 200 600 1200 300 50 50 9 120 400 NP 200 1000 1200 400 50 50 9 120 500 NP 330 1100 1200 500 50 50 9 120 750 NP 500 1200 1200 750 50 50 9 090...

Page 19: ...2500 150 1250 50 50 9 015 2000 NP 1100 4000 150 2000 50 50 9 015 3000 NP 2200 4000 150 3000 50 50 9 015 4000 NP 2500 8000 150 4000 50 50 9 0075 8000 NP 6000 16000 75 8000 50 50 9 0075 10000 NP 6000 18...

Page 20: ...Dimensions 17 Zolix Instruments Co Ltd http www zolix com cn E mail info zolix com cn 8 Dimensions...

Page 21: ...Ltd h Omni ector X C bS2900 320 aAs 1700 26 DSi200 30W Deuteri 18 http www z CR316 02 R 0 Pbs Ser 600 InGaAs 0 Dsi300 De ium Light So Other P olix com cn R1527 R152 ries IR Detec s Series Det etectors...

Page 22: ...w zolix com cn E mail info zolix com cn LHM254 Mercury Light Source Tunable light source GLORIA X150A GLORIA X500A Xenon light source GLORIA T150A Tungsten Halogen Light Source Series Tunable light TL...

Page 23: ...res Please open the packing box and make sure Do Not use the heavy duty tools or opens rudely With the proper tool according to the direction shown on the packing box so as not to cause inside equipme...

Page 24: ...ing flaws the company will repair or replace the same type of product As a result of human error or improper use or unauthorized repair and boot due to natural disasters and other irresistible factors...

Page 25: ...mni Grating Monochromator 1 No Accessories Amount 1 Power adaptor 1 2 USB Cable 1 4 Standard power cable 1 5 TDK magnetic ring 1 No Tools and Facilities Amount 1 Metric Hex wrenches 1 2 2mm Slit Cover...

Reviews: