background image

MATEC – ELECTRIC HEATING SYSTEMS
TEMPERATURE CONTROLLER RTS-02 

 

MANUAL INSTRUCTION

ZAMEL

 Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 32 449 15 00, +48 32 210 46 65, fax +48 (32) 210 80 04

www.zamel.com

, e-mail: [email protected]

OPERATION AND FUNCTIONALITY

6) A demand to display floor temperature.

In the operation mode where a room temperature sensor and a floor temperature limiter are used (position 8 of the configuration menu), pressing and hold-

ing the 

 button for 3 seconds causes current floor temperature displayes. In case the sensor is not mounted or is damaged - Er symbol will be displayed.

7) Current day and time adjustment.

●  Momentary pressing of the 

 button causes the hour pulsates.

●  Choose proper hour and AM / PM symbol by pressing and holding ▲ and ▼ buttons (AM shows time since midnight, AM shows time since noon).

●  After choosing the hour press again the 

 button. Minutes should pulsate.

●  Choose proper minutes by pressing and holding ▲ and ▼ buttons.

●  After choosing the minutes press again the 

 button. The days of the week should pulsate.

●  Choose a proper day by pressing and holding ▲ and ▼ buttons. Press once 

 button. The display should show proper time and day. if no button is pressed 

within 20 seconds  the regulator switches to the operation mode according to the adjusted programme

8) Programme planning.

It is recommended to see the default settings of Times and temperatures in an exemplary schedule. If the programme is suitable press button 

 so the regula-

tor starts operation according to the default settings. To change the adjusted times and temperatures follow the below description.  Specify demanded times 

and temperatures. Four time intervals must be programmed per one day. Temperature and starting time of the heating phase can be chosen independently. 

(For example, following settings can be chosen: 05:00 AM and 21°C for the beginning of the first heating time-interval for a workday, and also 07:00 AM and 

16,5°C for the first cooling time interval). It is recommended to write all time intervals and temperatures for all intervals in a table. A complete table enables 

to save the user’s programme.

Heating schedule (programme default setting):

Time interval

Days of the week (5 days)

Saturday

Sunday

Start time

Temperature

Start time

Temperature

Start time

Temperature

Heating

 

6:00 AM

21 °C

6:00 AM

21 °C

6:00 AM

21 °C

 

8:00 AM

16,5 °C

8:00 AM

16,5 °C

8:00 AM

16,5 °C

 

5:00 PM

21 °C

5:00 PM

21 °C

5:00 PM

21 °C

 

10:00 PM

16,5 °C

10:00 PM

16,5 °C

10:00 PM

16,5 °C

9) Heating programme introduction

1. Press once button 

.

 „PRGM SETTING”

 command displays. Pulsating symbols of weekdays „Mon Tue Wed Thu Fri” will be shown on a display with 

currently programmed start times for the first heating time interval. The temperature for this interval will also be shown. The icon 

 signals about 

programming of the first time interval (Get up).

2. Press button 

 to adjust programmed time and temperature. Press button 

 once (programmed temperature value will be displayed in a pulsating way). 

Press ▲ and ▼ buttons to change the displayed temperature for the first heating time interval.

3. Press button 

 once (programmed time value will be displayed in a pulsating way). Press ▲ and ▼ buttons to adjust the demanded time. Time displayed 

changes in a 15 minutes way. Press TIME button again after demanded time was chosen to return to the temperature change mode.  

4. Press button 

 once. The icon 

 for the second time interval programming is displayed (Go out). The display also shows currently adjusted start time 

and temperature for the second heating time interval. 

5. Repeat steps 2 and 3 to adjust parameters for the second time interval of the programme.

6. Repeat steps from 2 to 5 for the third and fourth time intervals of the programme.

7. Press button 

 once. „SA” symbol is displayed (programming for Saturday). The display also shows currently adjusted start time and temperature for 

the first heating time interval.

8. Repeat steps from 2 to 7 to insert programme data for Saturday.

9. Press button 

 once to adjust Sunday („SU”) and repeat steps from 2 to 7 to insert programme data for Sunday.

10. Press button 

 after inserting all data for the heating programme.

10) Return to the default settings.

Press button 

 to enter the programming mode. Press simultaneously ▲ and ▼ buttons for 3 seconds. 

„DEF”

 symbol is displayed three times (it pulsates), 

the programme returns to the setting phase. Press button 

 so the regulator can start operation according to the default setting. In case no button is pressed 

within 20 seconds the regulator returns to the operation mode compatible with the adjusted programme.

11) Control of the adjusted programme.

In order to check the adjusted programme settings before the programme starts, it is recommended to follow the below description. Press button 

 to to 

check the first time interval data for a working day. Pressing button 

 every time makes times and temperatures are displayed for the following time interval 

(sequentially) for working days, and next for Saturday and Sunday (every time and temperature can be changed while reviewing). Press button 

 so the 

regulator can start operation according to the adjusted programme.  

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product.

2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,

b) damage caused by incorrect product mounting or misuse,

c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices 

needed for the product functioning,

d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o.

e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);

3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.

5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.

6. The manufacturer’s guarantee is valid in the Republic of Poland.

7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

APPEARANCE

The device is designed for single-phase 
installation and must be installed in ac-
cordance with standards valid in a par-
ticular country. The device should be 

connected  according  to  the  details  included  in  this 
operating manual. Installation, connection and con-
trol  should  be  carried  out  by  a  qualified  electrician 
staff, who act in accordance with the service manual 
and the device functions. 
In case of casing dismantling an electric shock may 
occur, and the guarantee is lost then. Before instal-
lation make sure the connection cables are not un-
der voltage. The cruciform head screwdriver 2,5 mm 
should be used to instal the device. Improper trans-
port,  storage,  and  use  of  the  device  influence  its 
wrong  functioning.  It  is  not  advisable  to  instal  the 
device in the following cases:  if any device part is 
missing  or  the  device  is  damaged  or  deformed.  In 
case of  improper functioning of the device contact 
the producer.

The symbol means selective 

collecting of electrical and electronic 

equipment. It is forbidden to put 

the used equipment together with 

other waste.

CAUTION!

FEATURES

TECHNICAL DATA

DESCRIPTION

•  a big LCD display;

•  the LCD display shows simultaneously the 

adjusted  temperature  and  the  room  tem-

perature;

•  user’s settings and default settings are kept 

in a non-volatile memory;

• temperature is displayed in: Celsius or 

Fahrenheit (temperature) scales;

•  3 control modes - 

MODE  A:

 - control by 

means of a room sensor, 

MODE F:

 - con-

trol by means of a floor sensor, 

MODE AF:

 

- control by means of a room sensor with 

floor temperature limitation;

•  separate  programming  possibility  for  5 

weekdays and for a cycle of 1 day / 1 day 

(Saturday/Sunday);

•  programming with four separate time inter-

vals / temperature intervals during a day;

•  calibration possibility of a displayed tem-

perature value;

•  protection against freezing;

•  pump protection.

RTS-02 temperature controller is a pro-

grammable regulator. It is used to heat floors 
and  to  limit  floor’s  temperature.  The  device 
cooperates with electric and water floor heat-
ing systems. RTS-02 is equipped with battery 
supply backup (2 x AA battery).

RTS-02

Input (supply) terminals: L, N

Input rated voltage: 100 ÷ 240 V~

Nominal frequency: 50 / 60 Hz

Nominal power consumption: 0,40 W – STANDBY

Battery backup: Yes (2 x AA battery)

NTC senor terminals: RT2+, RT2-

Temperature sensor: NTC 100k dla 25 °C

Room temperature adjustment range: +5 ÷ +50 °C

Floor temperature control range: +5 ÷ +50 °C

Accuracy of temperature measurement: ±1 °C

Adjustment accuracy: ±0,5 °C

Output type: relay 16A dla 250 VAC

Number of terminal clamps: 7

Section of connecting cables: 0,5 ÷ 1,5 mm

2

Ambient temperature range: -5 ÷ +50 °C

Casing mounting: surface

Casing protection degree: IP21

Protection level: II

Overvoltage category: II

Dimensions: 90 x 115 x 29 mm (height x width x depth)

Weight: 0,180 kg

Reference standard: ETSI EN301 489-1, ETSI EN301 489-3,

EN 60730-1:2000+A12:2003, 

EN 60730-2-9:2002

1.

 Power supply button (Switch on / Switch off).

A bi-functional button to display the room temperature,

   the floor temperature and time adjustments.

3

 Default settings button.

Programme start confirmation button.

Reset button.

Maximum temperature adjustment button.

Minimum temperature adjustment button.

8.

 Current day or programmed days display. 

9.

 Cur-

rent time or programmed time display. 

10.

 Am: time in-

dication: morning and afternoon, Pm: time indication: 

afternoon and evening, Days: number of days, Hours: 

number of hours. 

11.

 Temperature scales display: Cel-

sius (°C) or Fahrenheit (°F). 

12.

 Temperature adjust-

ment range. 

13.

 Temperature limit excess in AF mode 

signalling.

14.

 Regulator’s programming mode signal-

ling. 

15.

 Pump protection mode signalling. 

16.

 16-A: 

Signalling of the mode operation with a room tempera-

ture sensor, 16-F:  Signalling  of  the  mode  operation 

with a floor temperature sensor, 16-AF: Signalling of 

the mode operation with a room temperature sensor 

and  a  floor  temperature  limiter. 

17.

  Heating  switch 

on signalling. 

18.

 Standby symbol. 

19.

 Time ranges:  

the remaining time to wake up 

, the remaining time to leave 

, the remaining time to return 

, the remaining 

time to go and rest 

20.

 Day / time adjustment: current time and day display. 

21.

 Prog setting: Signalling of the 

programme setting adjustment mode. 

22.

 Cofg: Signalling of regulator’s configuration mode. 

23.

 Signalling of the cur-

rent regulator’s operation mode. 

24.

 Signalling of the holiday temperature mode. 

25.

 Current room temperature display.

8

9

10 11

12

16

17

15

14

13

23

24

25

18

19

20

21

22

plik: inst_cet_en_rts-02 | modyfikacja: 20.04.2017