DESCRIPTION

This completely assembled unit includes a well-insulated
cabinet, a DX coil with copper tubes and aluminum fins, an
expansion valve, a distributor, throwaway filters, a centrifugal
blower, a blower motor, an adjustable belt drive, a blower motor
contactor and a small holding charge of refrigerant-22. The unit
is manufactured under ISO 9002 Quality System Certification.

The unit is shipped in the vertical position ready for field
installation. It can be installed for horizontal operation by
reversing the position of the solid bottom panel with the return
air duct flange on the front on the unit.

ACCESSORIES - FIELD INSTALLED

SUPPLY AIR PLENUM - A fully insulated plenum is available
for free standing units located within the conditioned space. It is
shipped knocked down for easy field assembly, is finished to
match the exterior of the basic unit, and has double deflection
grilles that can be adjusted to vary the throw, spread and drop
of the supply air.

RETURN AIR GRILLE - An expanded metal grille is available
for free standing units located within the conditioned space. It is
finished to match the exterior of the basic unit and is shipped in
one piece for easy installation.

BASE - A base is available to raise vertical units above the floor.
Outdoor air may be introduced through the base by cutting an
access opening to accommodate the outdoor air duct
connection. The base is finished to match the exterior of the
basic unit. It may have to be insulated in the field for certain
applications.

THREE-PHASE ELECTRIC HEATERS - Electric heaters are
available in four capacities to provide maximum flexibility. Both
the air conditioning unit and the heater can be selected to
precisely match the cooling and heating requirements of the

conditioned space. These heaters are designed for easy field-
installation over the supply air opening of the unit. Every heater
is fully protected against excessive current and temperature by
fuses and two high limit thermostats.

Units with electric heat require only one power supply for both
the heating elements and the supply air blower motor. The
power wiring can be protected by either dual element/time
delay fuses or an inverse time circuit breaker.

HOT WATER COIL - This drainable coil has two rows of 13mm (

1

2

in.) copper tubes, eight aluminum fins per 25mm (1 in.), a

casing that is finished to match the exterior of the basic unit, but
no water control valve. The coil slides out of the casing for easy
field installation. It should be mounted between the unit coil and
blower section.

STEAM COIL - The non-freeze coil has one row of 25mm (1in.)
copper tubes, a 16mm (

5

8

in.) copper tube inside each 25mm

(1 in.) tube to distribute the steam evenly across the entire
length of the coil, eight aluminum fins per 25mm (1 in.), a
casing finished to match the exterior of the basic unit, but no
steam control valve. The coil slides out of the casing for easy
field installation and is pitched in the casing to facilitate
condensate drainage. It should be mounted between the unit
coil and blower sections.

SUSPENSION KIT - Suspension kit 1HH0451 is available for
units installed horizontally. The accessory includes two
channel iron supports and the hardware to secure them to the
top of the unit. The hanger rods must be supplied by the field.

THERMOSTATS - Wall-mounted thermostats and subbases
(24volt) with system and fan switches are available to control
the operation of these split system air conditioners.

550.39-TG5YI (0601)

SPLIT-SYSTEM
EVAPORATOR BLOWER

K3EU180
15 NOMINAL TONS

SUNLINE 2000

® 

(WORLD 50 HZ)

Summary of Contents for SUNLINE 2000 KEU180

Page 1: ...can be selected to precisely match the cooling and heating requirements of the conditioned space These heaters are designed for easy field installation over the supply air opening of the unit Every he...

Page 2: ...Air Grille and Base accessories can be applied on arrangement b The Supply Air Plenum Return Air Grille and Suspension accessories can be applied on arrangement c Heater Model UL Test Voltage Nominal...

Page 3: ...ower Model Used On l s GPM m3 s CFM Entering Water Temperature Minus Entering Air Temperature C F 21 70 32 90 43 110 54 130 66 150 1HW0451 KEU180 0 95 15 2 3 4800 135 5 463 175 1 598 215 8 737 257 4 8...

Page 4: ...SP2 IWG OUTPUT BHP INPUT kW ESP2 IWG OUTPUT BHP INPUT kW 4800 CFM 5400 CFM 6000 CFM 6600 CFM 7200 CFM 600 0 46 1 44 1 34 0 30 1 68 1 56 0 11 1 96 1 80 615 0 55 1 54 1 43 0 40 1 79 1 64 0 22 2 08 1 90...

Page 5: ...04 0 05 0 06 0 07 Return Air Grille 0 04 0 05 0 06 0 07 0 08 Hot Water Coil 0 18 0 22 0 26 0 03 0 34 Steam Coil 0 15 0 18 0 22 0 26 0 30 Static resistance pascal Unit Model Accessory m3 s 2 26 2 55 2...

Page 6: ...rtical Louvers1 0 Spread Horizontal Louvers2 Vertical Louvers1 221 2 Spread Horizontal Louvers2 Vertical Louvers1 45 Spread Horizontal Louvers2 Throw Meters 3 Spread Meters 3 0 18 Throw Meters 3 Sprea...

Page 7: ...lectric Heater 10 kW 37 6 83 16 kW 29 9 66 26 kW 32 2 71 36 kW 33 5 74 Hot Water Coil Tube OD mm inches 1 2 12 7 copper Rows Deep 2 Fins per 25mm 1 in 8 aluminum Face Area square meters square feet 0...

Page 8: ...ll dimension of the unit will vary if an electric heater a supply air plenum or a base is used 2 This dimension is required for removal of the DX coil Only 660mm 26 in is required for normal servicing...

Page 9: ...tting on the electric heat accessory Connect the power wiring to the fuse block in the heater control box Route the control wires through the 22 2mm 7 8 in openings and connect them to the ter minals...

Page 10: ...hrough 0 AWG Accessory Model Nom kW Heater Dimensions mm inches A B C D E F G H K L M 2HS04501050 2HS04501650 2HS04502650 2HS04503650 10 16 26 36 692 271 4 641 251 4 362 141 4 25 1 102 4 13 1 2 140 51...

Page 11: ...11 550 39 TG5YI TERMINALS ON BLOCK 3TB OF THE BLOWER UNIT TERMINALS ON 1 STAGE COOLING THERMOSTAT 2TH13700424 FIELD WIRING Cooling only CONTROL WIRING Units with steam or hot water coil AC Units with...

Page 12: ...o change without notice Printed in U S A Copyright by York International Corporation 2001 All Rights Reserved 5005 York Drive 550 39 TG5Y 0601 Supersedes 550 39 TG5Y 0501 Norman OK 73069 Unitary Produ...

Reviews: