background image

24 V

制御電源ユニット

安川 

1000

シリーズオプション

取扱説明書

形式:

PS-A10LB, PS-A10HB

24 V Power Supply

YASKAWA 1000-Series Option

Installation Manual

Type: PS-A10LB, PS-A10HB

To properly use the product, read this manual thoroughly and retain 
for easy reference, inspection, and maintenance. Ensure the end user 
receives this manual.

製品を安全にお使い頂くために,本書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

MANUAL NO.  TOBP C730600 55D

Summary of Contents for PS-A10HB

Page 1: ...SKAWA 1000 Series Option Installation Manual Type PS A10LB PS A10HB To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user...

Page 2: ...e prior written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high qua...

Page 3: ...00 Series Option PS A10 Installation Manual 3 Table of Contents 1 PREFACE AND SAFETY 4 2 PRODUCT OVERVIEW 8 3 RECEIVING 9 4 OPTION COMPONENTS 10 5 INSTALLATION AND UNINSTALLATION PROCEDURE 12 6 VERIFY...

Page 4: ...gned to incorporate a product manufactured by Yaskawa must be supplied to the end user with appropriate warnings and instructions as to the safe use and operation of that part Any warnings provided by...

Page 5: ...ns troubleshooting and maintenance information The manuals also include important information about parameter settings and unit tuning Access these sites to obtain Yaskawa instruction manuals U S http...

Page 6: ...ding to the instructions described in this manual Any illustrations photographs or examples used in this manual are provided as examples only and may not apply to all products to which this manual is...

Page 7: ...onents in the unit or option Do not pack the unit in wooden materials that have been fumigated or sterilized Do not sterilize the entire package after the product is packed WARNING Read manual before...

Page 8: ...r or network communications when the unit switches to the option as a back up power supply Note 1 Parameter settings cannot be changed without unit main circuit power regardless of whether the control...

Page 9: ...ght edge screwdriver blade depth 0 4 mm width 2 5 mm is required to install the unit and wire the option terminal block Note Tools required to prepare option cables for wiring are not listed in this m...

Page 10: ...on Components 4 Option Components Option Figure 2 Figure 2 24 Vdc Power Supply Option Components A Connector cable E Terminal block TB1 24 Vdc power supply input B Connector tabs 6 C Model number F Op...

Page 11: ...le 2 Option Terminal Functions Terminal Function 24 24 Vdc Input 0 0 V FE Ground Option Model Code Input Specification Output Specification Lot Number Serial Number PS A10LB YASKAWA ELECTRIC CORPORATI...

Page 12: ...ower supply is turned off WARNING Electrical Shock Hazard Do not remove the front covers of the unit while the power is on Failure to comply could result in death or serious injury The diagrams in thi...

Page 13: ...t and circuit boards Failure to comply may result in ESD damage to circuitry Never shut the power off while the unit is running or outputting voltage Failure to comply may cause the application to ope...

Page 14: ...e 4 shows the installation distance required to maintain sufficient space for airflow and wiring Figure 4 Figure 4 Correct Installation Spacing Note IP20 NEMA Type 1 Enclosure and IP00 Open Chassis mo...

Page 15: ...iance Installation Area For compliance with UL and CE standards the option should be placed within the enclosure This product must be used in areas with an environment rating no greater than pollution...

Page 16: ...MR A 2A0004 to 2A0081 4A0002 to 4A0044 5A0003 to 5A0032 CIMR L 2A0018 to 2A0075 4A0009 to 4A0039 CIMR T 2A0004 to 2A0081 4A0002 to 4A0044 CIMR Z 2A0011 to 2A0114 4A0005 to 4A0096 CIMR D 2A0005 to 2A00...

Page 17: ...tor remains charged after the power supply is turned off NOTICE Damage to Equipment Observe proper electrostatic discharge procedures ESD when handling the option unit and circuit boards Failure to co...

Page 18: ...it An improper connection can damage the connector and the unit Figure 8 Figure 8 Plug the Connection Cable into the Unit 4 Align the connector tabs on the option with the insertion tabs on the unit a...

Page 19: ...Manual 19 5 Slide the option downward as indicated in Figure 10 to lock it into place on the unit For Z1000 drives use the tapping screw included in the package to attach the option Figure 10 Figure...

Page 20: ...ing The internal capacitor remains charged after the power supply is turned off NOTICE Damage to Equipment Observe proper electrostatic discharge procedures ESD when handling the option unit and circu...

Page 21: ...rt the blade of a straight edge screwdriver into the opening shown in Figure 13 Pull the connector cover in the direction indicated by the arrow and remove it from the unit Figure 13 Figure 13 Remove...

Page 22: ...to the unit An improper connection can damage the connector and the unit Figure 15 Figure 15 Plug in the Connector CIMR A 2A0110 6 Align the connector tabs on the option with the insertion tabs on the...

Page 23: ...rewdriver M4 and the screws included in the option package to fasten the option to the unit in the three locations shown in Figure 17 NOTICE Use only the screws packaged with the option other screws m...

Page 24: ...safe level and check for unsafe voltages before servicing The internal capacitor remains charged after the power supply is turned off NOTICE Damage to Equipment Observe proper electrostatic discharge...

Page 25: ...5D 1000 Series Option PS A10 Installation Manual 25 2 Remove the bracket used to hold the option in place Figure 20 Figure 20 Removing the Bracket CIMR A 4A0515 4A0675 Figure 21 Figure 21 Removing the...

Page 26: ...ption PS A10 Installation Manual 3 Pull the loose end of the connection cable out of the option Figure 22 Figure 22 Pull Out the Connection Cable 4 As shown in Figure 23 the cable and connector should...

Page 27: ...BP C730600 55D 1000 Series Option PS A10 Installation Manual 27 5 Connect the option to the bracket so that the connector tabs on the unit catch and hold it in place Figure 24 Figure 24 Connecting the...

Page 28: ...ions shown in Figure 25 NOTICE Use only the screws packaged with the option other screws may damage unit components Figure 25 Figure 25 Securing the Option to the Bracket 7 Firmly plug the end of the...

Page 29: ...e bracket reinstall the bracket back in its originally location Note Take proper precautions when connecting the option so the option will easily fit onto the unit Make sure the connector cable is not...

Page 30: ...55D 1000 Series Option PS A10 Installation Manual 9 Skip to Option Wiring on page 31 After wiring the terminal TB1 reinstall the unit covers to their original locations Figure 29 Figure 29 Reinstall t...

Page 31: ...terminal Take particular precaution to ensure that each wire is properly connected and wire insulation is not accidentally pinched into electrical terminals NOTICE Be sure to properly connect an exter...

Page 32: ...e customer Wire Gauges and Tightening Torques Table 4 Wire Gauges and Tightening Torques Terminal Number Screw Size Tightening Torque Nxm inxlb Bare Cable Crimp Terminals Wire Type Recomm Gauges mm2 A...

Page 33: ...2A0004 to 2A0081 4A0002 to 4A0044 5A0003 to 5A0032 CIMR L 2A0018 to 2A0075 4A0009 to 4A0039 CIMR T 2A0004 to 2A0081 4A0002 to 4A0044 CIMR Z 2A0011 to 2A0114 4A0005 to 4A0096 CIMR D 2A0005 to 2A0020 4A...

Page 34: ...e of a straight edge screwdriver as shown in Figure 32 and gently slide the option in the direction indicated by the arrow NOTICE Do not use excessive force when removing the option Failure to comply...

Page 35: ...move the three screws used to fasten the option into place during installation as shown in Figure 33 to uninstall the option Figure 33 Figure 33 Uninstallation Method B Uninstallation Method C After r...

Page 36: ...the red LED on the option indicating proper option operation 4 The digital operator on the unit will display Uv for about 10 seconds to indicate an undervoltage condition on the unit If Uv does not f...

Page 37: ...nt compatible with the unit environmental specifications Specifications Input Operating Voltage 24 Vdc 20 19 2 V to 28 8 V Input Current 1 9 A Consumption Power 38 W Output Ride Thru time when power i...

Page 38: ...late November 2013 Entire Documentation Addition Applicable models CIMR R 2A03P5 to 2A0073 4A03P5 to 4A0150 Revision Reviewed and corrected entire documentation Chapter 4 Revision Nameplate Back cover...

Page 39: ...Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC CHINA CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 East C...

Reviews: