manualshive.com logo in svg
background image

 

 

 
 

Digital Platform Scale 

 
 

Scalapro

 

 

(Model: DP-6900) 

 

 

OPERATION MANUAL 

 

 
 
 
 
 
 

YAMATO SCALE CO., LTD.

 

 

 

 

  Carefully read this operation manual and the product warranty, and then properly use this product.

  Keep this manual for future reference.

 
 

February 2016 

Содержание DP-6900

Страница 1: ...m Scale Scalapro Model DP 6900 OPERATION MANUAL YAMATO SCALE CO LTD Carefully read this operation manual and the product warranty and then properly use this product Keep this manual for future reference February 2016 ...

Страница 2: ...daptor option 9 2 5 Display panel and operation keys 10 3 Basic operations 11 3 1 How to weigh an item 11 3 2 How to reset the indication to zero 11 3 3 How to turn off the power 11 4 One touch tare function 12 4 1 How to enable the one touch tare function 12 4 2 How to check the gross weight when the tare function is enabled 12 4 3 How to exit the one touch tare function 12 5 User parameters 13 5...

Страница 3: ... indicates a mandatory action that you must do Before using this product carefully read and understand the following instructions labeled as Danger Warning and Caution and ensure to observe them Danger To avoid an electric shock 1 Do not step on the AC adaptor cable with your foot or run over it with the wheels of a cart or other equipment 2 Never remove any parts installed with screws such as the...

Страница 4: ...push the display panel or operation keys with your fingernail or a pointed object 2 Observe the specified input voltage and operating conditions 3 Do not place anything heavier than the weighing capacity on the weighing platform 4 Do not apply any excessive impact or vibration to the weighing platform for example by dropping an item on it 5 Do not disassemble or modify the instrument To maintain t...

Страница 5: ...operating range measurement results may become inaccurate under the following conditions where condensations occur 1 When the instrument has been used or stored in a humid environment for a long time 2 When the instrument has been exposed to sudden temperature change even if the humidity is low e g cold water has been splashed onto the instrument 3 When the instrument has been used in an atmospher...

Страница 6: ... Scalapro has the following functions Make use of these functions according to your work Purpose Method Q1 I want to display the weight of an item or a container as zero on the panel Answer One touch tare function Sec 4 1 You can subtract tare by simply pressing the Tare key Q2 I want to check the gross weight or net weight of items Answer Gross Net switching function Sec 4 2 When the tare functio...

Страница 7: ...ration manual this manual warranty card Size D battery x 4 for the monitor AC adaptor 1 5 Name of each part Pole Indication unit Display panel Pole bracket Spirit level Leveling leg Weighing platform Operation keys Platform cover Bubble type spirit level ...

Страница 8: ... wipe stains off the instrument with the cloth 3 wash the instrument with clean water and then 4 carefully wipe off moisture with a clean dry cloth Wash the display panel with clean water Never disassemble or modify the instrument Otherwise it may deteriorate the water proof performance of the instrument Be sure to contact your vendor if by any chance you have disassembled the instrument by mistak...

Страница 9: ...ecome inaccurate Placing the instrument on a wobbly surface will also result in inaccurate measurement Note Do not place the instrument on a slanted floor if the slant is too large to be adjusted On the underside of the instrument there are leveling legs for adjusting its levelness Place the instrument on as flat a surface as possible and turn the leveling legs so that the bubble in the spirit lev...

Страница 10: ...y reduce the life of the batteries Note 2 Do not mix different types of batteries e g manganese battery with alkaline battery 2 4 How to set the AC adaptor option Firmly insert the plug for AC adaptor into the jack located in the lower back of the indication unit Open the battery case You can see four size D batteries Remove those batteries Note 1 Be sure to use the dedicated AC adaptor If you use...

Страница 11: ...he checkweighing function hold down this key to start setting a target value This key can also be used to decrease various setting values by 1 Tare key Press this key to show the weight of a container as zero Then the system subtracts the weight as tare This key can also be used to increase various setting values by 1 Zero Reset key If the indication is deviated from zero before weight measurement...

Страница 12: ...on LED light come on and then the panel shows 0 Put the item on the instrument The panel shows the weight of the item 25 kg When the measured weight becomes stable the STABLE sign comes on 3 2 How to reset the indication to zero Operation Display Press The value on the panel is reset to zero 3 3 How to turn off the power Operation Display Hold down The power is turned off ...

Страница 13: ...e container weight 4 2 How to check the gross weight when the tare function is enabled When the tare function is enabled press to switch the indicated value between the gross and net weights Operation Display When the panel shows a net weight press The GROSS sign comes on and the panel shows the gross weight Net weight Gross weight 4 3 How to exit the one touch tare function Example When you remov...

Страница 14: ...lost 5 3 User parameter table Number Item Setting value Description of options The underlined option is the factory setting 01 Checkweighing function 0 Disable the checkweighing function 1 Simplified checkweighing function 2 Inspection checkweighing function The upper and lower limits are set using the measured weight of a sample as the middle value 03 LED lighting timing 0 Disable LED parameter f...

Страница 15: ...Flashing of indicated value per evaluation parameter for checkweighing function When the checkweighing function is enabled you can make a setting so that the indicated value flashes For example if you set it to flashing when the weighed items have the proper weight the evaluation result will be clearer 09 Gravity compensation for the region of use Make this setting when you use the instrument for ...

Страница 16: ...0 kg and the scale interval is 0 01 kg Inspection checkweighing function 01 2 The weight of measured sample s becomes the middle value of the proper weight range The system automatically sets the upper limit and lower limit of the proper weight range based on the amount specified in the parameters Example if the measured weight of the samples is 2 00 kg and the scale interval is 0 01 kg Proper wei...

Страница 17: ...ion Display Press and at the same time to enter the user parameter setting mode and then set the parameter 01 to a function you use Using the key 1 or 1 toggle between the options When you reach the option you use press to switch to the next parameter 0 Disable the checkweighing function 1 Simplified checkweighing function 2 Inspection checkweighing function When the setting is complete press to t...

Страница 18: ...rease the target value by 1 scale interval At that time if the weighing value becomes unstable the adjusted indication will be canceled Press to register the target value The system displays the lower limit and then the upper limit Now it is ready to start weight measurement During measurement the CHECK sign changes from flashing to steady light The upper limit is automatically determined by the t...

Страница 19: ...hows 0 with the checkweighing function enabled pressing terminates the checkweighing function How to confirm the setup values and start weight measurement 2 Operation Display Confirm that the panel shows 0 Press to display the lower limit If you hold down at this point you can clear the setting Press to display the upper limit If you hold down at this point you can clear the setting Press to start...

Страница 20: ...n comes on while the items are underweight Underweight 3 When you put items of the proper weight the Evaluation LED light comes on Proper weight 4 When you put items exceeding the proper weight range the Up Arrow sign comes on Remove the excess from the instrument Overweight 07 Flashing of indicated value per evaluation 0 Disable flashing Factory setting 1 Flash upon underweight 2 Flash upon prope...

Страница 21: ...n comes on while the items are underweight Underweight 3 When you put items of the proper weight the Evaluation LED light comes on Proper weight 4 When you put items exceeding the proper weight range the Up Arrow sign comes on Remove the excess from the instrument Overweight 07 Flashing of indicated value per evaluation 0 Disable flashing Factory setting 1 Flash upon underweight 2 Flash upon prope...

Страница 22: ...calapro for a purpose other than transactions or certifications the user can compensate for gravitational acceleration according to the region of use and carry out span adjustment Refer to the user parameter table and set the parameter before use Number Name Setting Function description 09 Regional compensation gravitational acceleration 0 No regional compensation gravity compensation 1 to 29 Not ...

Страница 23: ...e a compensated instrument in an area with a different setup value you need to compensate again for the gravitational acceleration corresponding to the region of use Gravity compensation for the region of use Example If you use the instrument in Bangkok Thailand Gravitational acceleration 9 783 m s2 Formula 9 783 9 7600 10000 5 30 76 therefore the setup value is 76 Operation Display Press and at t...

Страница 24: ...lay Press and at the same time to enter the user parameter setting mode Press and at the same time while the parameter 01 is displayed The weight calibration screen appears Press to start a calibration Put 30kg weight s which is equivalent to 3000 scale intervals and then press Put 15kg weight s when the weighing capacity is 32kg or put 60kg weight s when the weighing capacity is 120kg Put 60kg we...

Страница 25: ...ss the Zero Reset key If the platform cover is removed place it again Unable to weigh Measured weight is more than the weighing capacity 5 scale intervals Remove the item s which returns to measuring mode Use the instrument within the weighing capacity Unable to weigh This code may appear when you turn on the power with a heavy item put on the weighing platform Turn on the power with nothing put o...

Страница 26: ...persists contact your vendor Electronic circuit error An error has occurred at an electronic circuit Turn off the power and then turn it on again after a while If the error still persists contact your vendor Electronic circuit error An error has occurred at an electronic circuit Turn off the power and then turn it on again after a while If the error still persists contact your vendor E2PROM write ...

Страница 27: ...function is used Underweight sign Comes on when the checkweighing function is used Battery sign Displayed at three levels depending on the remaining battery 6 Functions 1 Zero reset function Resets the indication to zero within 1 9 of weighing capacity 2 One touch tare function Conducts the one touch tare function 3 Automatic OFF function The power is automatically turned OFF when the STABLE sign ...

Страница 28: ...wer consumption 36mW 12 Operating conditions 1 Operating temperature range 10 C to 40 C 2 Operating humidity range 30 to 85 R H no condensation 13 Options RS232C communication 8 3 Dimensional outline drawing ...

Страница 29: ......

Страница 30: ...YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5562 PRINTED IN JAPAN ...