1
Board Unit (Schematics, Layouts & Parts)
RF Unit ............................................................................................................................................................................. 19
AF Unit ............................................................................................................................................................................ 33
CNTL Unit ....................................................................................................................................................................... 45
VCO Unit ......................................................................................................................................................................... 59
©2003 VERTEX STANDARD CO., LTD.
EH009M90B
Technical Supplement
VX-7R
50/144/430 MHz Triple-Band
Heavy Duty Submersible Transceiver
Introduction
This manual provides the technical information necessary for servicing
the VX-7R 50/144/430 MHzTriple-Band Heavy Duty Submersible Trans-
ceiver.
Servicing this equipment requires expertise in handing surface-mount
chip components. Attempts by non-qualified persons to service this
equipment may result in permanent damage not covered by the war-
ranty, and may be illegal in some countries.
Two PCB layout diagrams provided for each double-sided board in
this transceiver. Each side of the board is referred to by the type of the
majority of components installed on that side ("Side A" or "Side B"). In
most cases one side has only chip components, and the other has either
a mixture of both chip and leaded components (trimmers, coils, electro-
lytic capacitors, ICs, etc.), or leaded components only.
While we believe the information in this manual to be correct, VER-
TEX STANDARD assumes no liability for damage that may occur as a
result of typographical or other errors that may be present. Your coop-
eration in pointing out any inconsistencies in the technical information
would be appreciated.
Contents
DW
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
Summary of Contents for VX-7R
Page 5: ...5 Block Diagram ...
Page 6: ...6 Interconnection Diagram ...
Page 21: ...21 RF Unit Lot 4 Circuit Diagram ...
Page 35: ...35 AF Unit Lot 3 Circuit Diagram ...
Page 37: ...37 AF Unit Lot 4 Circuit Diagram ...
Page 47: ...47 CNTL Unit Lot 3 Circuit Diagram ...
Page 49: ...49 CNTL Unit Lot 4 Circuit Diagram ...
Page 58: ...58 CNTL Unit Note ...
Page 63: ...63 Note ...