background image

 

 

 

 

 

 

 

 

        4GBOX   

wireless data transmission module   

User manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           

WUXI  XINJE  ELECTRIC  CO.,  LTD. 

 

File  No.  MC08  20170724  3.5 

Summary of Contents for 4GBOX

Page 1: ...4GBOX wireless data transmission module User manual WUXI XINJE ELECTRIC CO LTD File No MC08 20170724 3 5...

Page 2: ...OVERVIEW 10 3 2 REMOTE CONFIGURATION 10 3 3 FLAG REGISTER 11 3 4 USER AUTHORITY 12 3 5 MESSAGE FUNCTION 13 3 5 1 Message phone 4G BOX PLC 13 3 5 2 Message PLC 4G BOX phone 14 4 1 PREPARTION 15 4 2 MO...

Page 3: ...5 2 2 Function setting 22 5 3 ONLINE MONITORING 23 5 3 1 Get remote information 23 5 3 2 Remote monitoring 23 APPENDIX 24...

Page 4: ...al and intelligent service for equipment manufacturing production and processing urban construction warehousing and logistics intelligent agriculture and other industries 4GBOX module include two type...

Page 5: ...t Version XD Hardware V3 4 5 and up Software V3 5 1 and up Hardware V3 4 5 and up Software V3 5 and up XC XC2 series and up XCPPro V3 3r and up ModbusRTU Support 0 1 3 4 address Application The applic...

Page 6: ...for the following automation fileds Remote diagnosis of equipement fault Equipment after sales reliable maintenance such as air compressor maintenance Data authenticity guarantee of test equipment suc...

Page 7: ...XD 4GBOX ED...

Page 8: ...GPS antenna optional 2 2 Dimension XD 4GBOX ED The dimension is 25 0mm 100 0mm 90 0mm width height depth Please use M3 screw to fix or install on the DIN46277 width is 35mm rail...

Page 9: ...re wiring 3 Make sure the connection is strong the loss of connection will result in incorrect data short circuit etc installation wiring and other operations must be performed after the power supply...

Page 10: ...only for connecting Modbus RTU device to monitor the data It supports XC series PLC online programming and debugging XD series PLC only support online data monitoring in RS485 connection mode seemed a...

Page 11: ...L3 will show the error type please see below table L0 L1 L2 L3 Explanation flashing No SIM card or SIM card insert error flashing flashing 4GBOX cannot open the network SIM card arrears or not open t...

Page 12: ...ory mode please turn if off for normal using 4GBOX M only for V1 1 2 and down version S1 S2 S3 S4 Function OFF OFF Running mode ON OFF back to default serial port parameters when power on again ON Con...

Page 13: ...GSM GPRS 2W EDGE 0 5W UMTS 0 25W LTE 0 25W Working temperature 10 50 Average standby current 5mA 3 Function settings 3 1 Function overview 4GBOX supports XD and XC series PLC Modbus RTU device When i...

Page 14: ...nfo IP address If the domain name is default settings it no needs to fill in the IP If not fill in the domain name please fill in XINJE server IP address 61 160 67 86 Device password Set 4GBOX remote...

Page 15: ...n the GPS position in PLC appointed address every 5s after module initialization The position information occupied 4 registers two floating numbers which are latitude and longitude Note 1 Serial port...

Page 16: ...nent Sending message format W M0 1 set ON M0 Sending message format W Y23 0 set OFF Y23 Sending message format W Y35 1 set ON Y35 Sending message format W D5 K1234 D5 1234 decimal format Sending messa...

Page 17: ...G BOX phone The 4GBOX will send message to user s phone in certain condition Please refer to below example The trigger coil should be edge signal falling or rising edge of pulse In the message configu...

Page 18: ...and software version meet the requirements in chapter 4 1 4 2 1 Serial port setting 4 2 1 1 XD 4GBOX ED configuration XD series PLC serial port communication protocol includes Modbus RTU XNET OMMS TB...

Page 19: ...light will flash periodically when the serial port parameters are consistent Note the default serial port baud rate can fit for most of the applications for some applications that the electromagnetic...

Page 20: ...Serial port speed 115200bps Physical layer RS232 Network ID 32768 Station number 1 When configuring the serial port parameters please set the DIP switch as below and power on again S1 S2 S3 S4 functi...

Page 21: ...3 Online monitoring 4 3 1 Get remote information After configuring the 4GBOX the PLC software can connect to the remote PLC in running mode It needs to input 4GBOX ID and password when connecting The...

Page 22: ...device ID of 4GBOX Click 4GBOX in the project bar then click 4GBOX version it will show version 1 1 4 ID 020 001 002 D010 0001 User also can check this ID on the product label There is no password fo...

Page 23: ...Open the message function optional XC2 and up series PLC hardware V3 3 and up XCPPro programming software V3 3r and up XINJEConfig tool version v1 6 343 and up XC series PLC programming cable PC enab...

Page 24: ...ol Modbus RTU Serial port speed 19200bps Data bit 8 Stop bit 1 Parity even 4GBOX default serial port parameters are same as above table please ensure the serial port parameters of the two devices are...

Page 25: ...5 2 2 Function setting Open XCPPro software click software serial port config 4GBOX connects to PC via programming cable the window shows connection succeeded Please refer to chapter 3 for details...

Page 26: ...It needs to input 4GBOX ID and password when connecting The 4GBOX ID can be checked on the label the default password is vacant If user cannot remember the ID and password please configure again refe...

Page 27: ...odbus RTU device it can remote monitor the device via Cloud web or other upper computer by calling SDK but cannot monitor via XCPpro software Appendix When using the remote communication PLC software...

Page 28: ...failure 3 can t find port 4 find device timeout 5 bind device failure The error will appear when downloading or uploading 200 comm error Frame error 201 comm check error CRC error 202 DLL send timeou...