Page 2: ...ion of Conformity 3 Safety Information 4 Introduction 8 System Components 8 PS Power Supply 8 Compatible Devices 8 Power Data Cable 9 System Layout Diagram 9 Equipment Compatibility 9 Installing Connecting the Power Supply 10 Head Feet Restrictions 10 Mounting and Installation Accessories 11 Cables 13 Specifications 14 Parts List 15 Warranty Information 16 ...

Page 3: ...3 ...

Page 4: ...gainst electric shock is assured only if the mains connected power supply cord set is connected to a properly earthed grounding type receptacle An all pole disconnect device must be located adjacent to the unit or if the AC cord is used as the main disconnect device ensure that the socket outlet is located installed near the equipment and is easily accessible THE MAINS LEADS ARE COLORED IN ACCORDA...

Page 5: ...re la décharge électrique est seulement assurée si la série de corde connectée principale est connectée à un convenablement terre de type Un appareil débranchant doit être localisé à côté de l unité ou si la corde de courant alternatif est utilisée comme le principal débranche l appareil S assurer que la douille sortie localise installé près de l équipement et est facilement accessible LES AVANCES...

Page 6: ...asegura sólo si el conjunto conectado principal de cuerda es conectado a un apropiadamente earthed que muele receptáculo de tipo Una toda asta desconecta dispositivo se debe localizar adyacente a la unidad o si la cuerda de C A se utiliza como el principal desconecta dispositivo asegure que la enchufe salida localiza instalado cerca del equipo y sea fácilmente accesible EL PRINCIPAL DIRIGE SON COL...

Page 7: ...st nur gezusichert wenn die Hauptleitungen Schnursatz verbunden haben ist an eine ordentlich earthed Erdung von Behälter angeschlossen Eine alle Stange schaltet Vorrichtung muss sich befunden werden neben der Einheit ab oder Wenn die AC Schnur benutzt ist während die Hauptleitung Vorrichtung abschaltet Sichert dass der Steckdosensteckdose ist befunden nahe die Ausrüstungen installieren und ist lei...

Page 8: ...is currently only compatible with Forerunner and NexeraLX DO NOT connect PS Power Supplies to RAM ColoramII devices ColoramII CXI GoboramII or Eclipse and DO NOT connect Forerunner or NexeraLX to RAM Coloram II Power Supplies Damage from such action will not be covered by the equipment warranties Compatible Devices At the time of printing of this manual the PS 150 PS 300 and PS 600 Power Supplies ...

Page 9: ...site at www wybron com Power Supply PS 150 PS 300 PS 600 Model Number 20150 20300 20600 Output Power 150 watts 300 watts 600 watts Quantity per Power Supply Description Model Max Head Feet PS 150 PS 300 PS 600 NexeraLX tungsten 2560 2570 2640 1500 8 16 32 NexeraLX CDM 2580 2600 2650 1500 6 12 24 Forerunner 4 inch 4540 n a 16 32 64 Forerunner 7 inch 7140 n a 16 32 64 The above information assumes d...

Page 10: ...ack mount kit The rack mount kit will accommodate two power supplies side by side 2 Connect the device to the power supply Connect the device to the power supply using a 4 pin Wybron Power Data cable Refer to the HEAD FEET RESTRICTION section of the manual for details of the length of cable runs Note The Wybron Power Data Cable has been specially designed to minimize voltage drop use only Wybron s...

Page 11: ...able is too long or you have too many sprinkler heads color changers the water pressure voltage will be too low HEAD FEET is defined as the sum of cable lengths from each device to a single power supply output Refer to the user manual of the specific components for detailed head feet information on those products Mounting and Installation Accessories The following sections describe the procedures ...

Page 12: ...nto the rack mounting tray 1 Disconnect AC power from the power supply 2 Place the rack mount tray right side up on a flat surface 3 Position the power supply in the rack mount tray as shown below 4 Attach the power supply to the rack mount tray using the supplied screws Note The cover plate may be removed to allow installation of a second power supply 90 25 0 VA C 50 60 HZ 4 AM P SL O B L O AT 11...

Page 13: ...ssis to chassis of the equipment The twisted pair shield is connected at male XLR connector end only XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24VDC 14 AWG DMX512 Control Cable The DMX control cable from the lighting console to the power supply is a five conductor cable with 5 pin XLR connectors on each end The wiring pin out is specified ...

Page 14: ...40V 50 60 Hz 5 3A 250V 4A Slo Blo for 100 120V 250V 2A Slo Blo for 220 240V PS 600 model 20600 Input voltage 100 240V 50 60 Hz 10 5A 250V 7A Slo Blo for 100 120V 250V 4A Slo Blo for 220 240V Input Power Automatically accepts 100 240V 50 60 Hz Input Signal 1990 USITT standard DMX512 Red LED Indicates power Green LED Indicates DMX signal Size PS 150 12 7 323mm L x 7 6 193mm W x 2 9 74mm H Weight 3 9...

Page 15: ...S 300 and PS 600 hanger bracket SCRWC252075 Wing screw for power supply hanger bracket to pipe SCRSC2520037 Socket cap screw for hanger bracket to power supply Power Data Cable 7042 3 3 power signal cable 7042 5 5 power signal cable 7042 10 10 power signal cable 7042 15 15 power signal cable 7042 25 25 power signal cable 7042 50 50 power signal cable 7042 75 75 power signal cable 7042 100 100 powe...

Page 16: ...for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at their factory or authorized service center This warranty is co...

Reviews: