User Manual 

 
 
 
 

 

 
 

 

 

 
 
 
 
 

W

W

W

I

I

I

T

T

T

U

U

U

R

R

R

A

A

A

 

 

 

C

C

C

O

O

O

R

R

R

P

P

P

O

O

O

R

R

R

A

A

A

T

T

T

I

I

I

O

O

O

N

N

N

 

 

 

S

S

S

D

D

D

N

N

N

 

 

 

B

B

B

H

H

H

D

D

D

 

 

 

Summary of Contents for WT-009

Page 1: ... M R R Re e em m mo o ot t te e e C C Co o on n nt t tr r ro o ol l l D D De e ev v vi i ic c ce e e User Manual W W WI I IT T TU U UR R RA A A C C CO O OR R RP P PO O OR R RA A AT T TI I IO O ON N N S S SD D DN N N B B BH H HD D D ...

Page 2: ...te Control Device WT 009 USER MANUAL Rev 2 3 Technical Support technical witura com COPYRIGHT 2008 WITURA CORPORATION SDN BHD Electronic KIT to convert your gate into a GSM gate WT 009 GSM Remote Control Device Diagram ...

Page 3: ...e as easily as they can do with a standard remote control 2 Flexible you can add or remove anybody number in a minute with an SMS 3 Cheap you don t need to buy a remote control for each member of your family 4 Convenient no matter if you change car or if you have different gates to open Your phone will always be with you all the times your remote controls were somewhere else Installation To instal...

Page 4: ...vice will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so If you don t do it and switch on the unit more than 3 times you will have to reset the PIN using the PUK You can program the WT 009 with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know ...

Page 5: ...e White List You can add up to 64 numbers in the list Every position must be indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position To add a number the syntax of the command is the following PWD123456 WHL01 3593334444 Where 01 is the position in the list and 3593334444 is the number enabled Please note that it is possible to p...

Page 6: ... it and this has a cost The CAP command must be issued 2 times to be sure you don t digit a wrong one Of course it must be preceded by the old password For example to change the password 123456 into the new password 333444 you need to send the following SMS PWD123456 CAP333444 CAP333444 You will receive a confirmation with CAP OK if you wrote correctly GOT Gate pulse time This command is useful in...

Page 7: ...to count the input active pulses up to 1ms fast or activate the output relay Note When used as counters input work only in ACTIVE HIGH mode They count ONLY High Going Pulses One of the most important functions is to receive alarms In order to do this properly you must turn on the function of the input and tell the WT 009 which are the recipient numbers and who should receive the alert message for ...

Page 8: ...changed at any time by sending the following commands by SMS message to the unit Text Command RERN XXXXXXXX XXXXXXXX stands for 8 digits value ON 1 or OFF 0 for the 8 administrators For example if you assume only administrators 1 2 3 and 4 are to receive text alerts you would send the following SMS message to the unit PWD123456 RERN 11110000 Note You can only put 1 in the first 4 digits of the tex...

Page 9: ...XX XXXXX stands for the display text that you want to program For example if you want the alert message to display Garage Opened when received a text alert you would send the following SMS message to the unit PWD123456 STR Garage Opened To turn on the function of input you can send the following commands by SMS message to the unit Text Command CTR X X stands for ON 1 or OFF 0 value To turn on the ...

Page 10: ...message each time the input has triggered for 5 times you would send the following SMS message to the unit PWD123456 COA 00005 This input can be programmed to behave differently it can count the input active high pulses generate an alarm message or activate relay To program the input you can send the following commands by SMS message to the unit Text Command CTC F F stands for input function 1 5 F...

Page 11: ... relay 2 for 1 second Sends a counter alert message once alarm counter reaches the alert value Function 5 Sends an alert message once triggered For example assume you want it to send an alert message each time the input triggered you would send the following SMS message to the unit PWD123456 CTC 5 To read the total increment counter value you can send the following SMS message to the unit Text Com...

Page 12: ...ounter value will be reset automatically each time the alarm counter reached the alert value To reset the total counter value you can send the following SMS message to the unit Text Command CLA The syntax of the command is the following PWD123456 CLA To activate the output relay you can send a text command via SMS specifying the number of seconds the output should stay on to the unit It is possibl...

Page 13: ... To check the status of output relay PWD123456 RLY Note The reply message will be send to the recipients The Administrators only when the relay has turned on off This is to notify the administrators when someone outside the list activates the relays To activate the output relay to stay on you can send the following commands by SMS message to the unit Text Command RLOP N X N stands for number 1 or ...

Page 14: ...ion 0 This function is disabled Normal Mode Default Function 1 Relay 1 will turn off for 10 seconds and turn on again After 30 seconds Relay 2 will be off for 5 seconds and turn on again Function 2 At a programmable time section Relay 1 or 2 will turn off for a programmable time in seconds and turn on again Note Once this function is used the relays will operate automatically according to the prog...

Page 15: ... Group number 1 8 R stands for Relay number 1 or 2 Example 1 assume you want output relay number 1 to turn off for 20 seconds on 8 30am you would send the following SMS message to the unit PWD123456 SMW 00 30 08 020 1 1 Example 1 assume you want output relay number 2 to turn off for 30 seconds on 5 30pm you would send the following SMS message to the unit PWD123456 SMW 00 30 17 030 1 2 Note You ca...

Page 16: ...Time setting is necessary for operating function 2 at 5 3 1 To set the output relay 2 to supply DC voltage when activated please adjust the jumper according to the below diagram To set the output relay 2 to use dry contact Default when activated please adjust the jumper according to the below diagram 5 4 Setting the Output Relay 2 to Supply Voltage or use Dry Contact when Activated ...

Page 17: ...nnot open the gate Verify that they send the caller ID when calling another phone Check that the number you see in the other phone is what you have programmed in the GSM Remote Control Device I have inserted the SIM but the unit doesn t work Check to have removed the PIN request from the SIM If you didn t do it and you have switched on the unit more than 3 times you may need to use the PUK Check w...

Page 18: ...ects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 009 is a product of Witura Corporation Sd...

Reviews: