background image

Pool Pumps

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.

© 2000 Wayne Water Systems

Operating Instructions and Parts Manual

Inground and Above Ground Units

To reduce the risk 
of injury, do not

permit children to use this product
unless they are closely supervised at
all times.

This pump is for 
use with perma-

nently installed pools. If specified, the
pump may be used with hot tubs and
spas. Do not use with storable pools.
A permanently installed pool is con-
structed in or on the ground or in a
building such that it cannot be readily
disassembled for storage. A storable
pool is constructed so that it may be
readily disassembled for storage and
reassembled to it’s original integrity.

Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.

All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local codes and the
National Electrical Code.

2. Do not install within an outer

enclosure or beneath the skirt of
the hot tub or spa, unless so
marked.

Installation

LOCATION

Disconnect, tag and lock
out power source before
attempting to install, ser-
vice, relocate or perform
any maintenance.

Locate pump as close to pool/spa as
possible. Install the pump on a hard,
level surface that is dry, well ventilated

!

DANGER

!

WARNING

!

WARNING

!

CAUTION

!

WARNING

320401-001  8/00

and away from direct sunlight. The sur-
rounding area should provide protec-
tion from the elements and ample
room for maintenance and service.
Ensure the drainage will flow away
from the pump.

Above ground pool pumps

are not

self-priming. If suction line valves are
installed, the pump may be located
above water level. Keep the vertical dis-
tance from the water level to a mini-
mum. Otherwise, the pump must be
located below filled water level to facil-
itate priming.

Inground pool pumps

are self-prim-

ing. Mount pump below water level for
easy priming. If the pump must be
located above the filled water level,
keep the vertical distance to a mini-
mum.

GENERAL PLUMBING

SOLVENT WELD CONNECTIONS

Use rigid or flexible PVC pipe. Ensure
pipe ends are clean and free of any
flash caused by the cutting operation.
Use the proper adhesive for the type of
pipe specified.

NOTE: 

Use an adhesive primer to

ensure adhesive joints are secure.
Suregard P-3000 has a purple tracer to
qualify in areas where codes specify a
primer must be used.

Description

This swimming pool pump is designed for
use with permanently installed pools only.

Unpacking

After unpacking the unit, carefully
inspect for any damage that may have
occurred during transit. Check for
loose, missing or damaged parts.

Danger indicates 
an imminently haz-

ardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially haz-

ardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 
potentially haz-

ardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 

important informa-

tion, that if not followed, may cause
damage to equipment.

This manual contains information that
is very important to know and under-
stand.  This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS.  To help recognize this
information, observe the following:

1. Read these rules and

instructions carefully.
Failure to follow these
instructions could
cause serious bodily
injury and/or property
damage.

!

NOTICE

!

CAUTION

!

WARNING

!

DANGER

READ & 

FOLLOW ALL

INSTRUCTIONS

SAVE THESE

INSTRUCTIONS

DO NOT DISCARD

IMPORTANT 

SAFETY 

INSTRUCTIONS

MANUAL

PVC - PVC Joint

PVC - ABS Joint

Uni-Weld

Uni-Weld 

Pool-Tite 2000

Pool-Tite 2000

Suregard Flex 20

Suregard Weld
All No. 5

IPS Weld-On 705

IPS Weld-On 794

*

These recommendations are examples only
and are not intended to restrict brands

RECOMMENDED ADHESIVES*

Reviews: