This equipment must be installed and serviced by a qualified technician in accordance with all applicable codes 
and ordinances. Improper installation can create hazards which could result in property damage, serious injury 
or death. Improper installation will void the warranty. 

The NOTICE label indicates special instructions that are important but not related to hazards. 

 
   
 

Notice to Installer 

This manual contains important information about the installation, operation and 
safe use of this product. Once installation is complete, this manual must be 
given to the owner/ operator of this equipment.

   

 

WARNING

 

 

Summary of Contents for SINGLE SPEED

Page 1: ...can create hazards which could result in property damage serious injury or death Improper installation will void the warranty The NOTICE label indicates special instructions that are important but not related to hazards Notice to Installer This manual contains important information about the installation operation and safe use of this product Once installation is complete this manual must be given...

Page 2: ...tor rating when the pump is operating Locate pump on a non combustible surface as close to the pool spa as possible The surface should be hard level dry and well ventilated The surrounding area should provide protection from the elements and allow sufficient space for maintenance and service Ensure the drainage will flow away from the pump To reduce vibration and pipe stress use anchor bolts to se...

Page 3: ...ads with one to two layers of Teflon tape Cover entire threaded portion Do not over tighten If leaks occur remove pipe clean off old tape rewrap with one to two additional layers of tape and remake the connection Fittings Fittings restrict flow for best efficiency use the fewest number of possible fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Ass...

Page 4: ...or seriously damage motor and voids warranty Voltage Voltage at motor must be within 10 of the motor nameplate rated voltage or motor may overheat causing overload tripping and reduced component life If voltage does not fall within the specified range during operation consult the power company Grounding Bonding Install ground bond and wire motor according to local or National Electrical Code requi...

Page 5: ... higher than pump pump will prime automatically during suction and discharge valves are opened If the pump is located above the normal pool water level remove ring and cover assembly and fill basket and pump with water Clean and inspect o ring then reinstall on trap Replace ring and cover assembly then rotate clockwise to tighten cover NOTICE Tighten ring and cover assembly by hand do not use tool...

Page 6: ...d electrically test the pump motor FAILURE TO PUMP REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks lost prime 1 Pump must be primed Make sure that pump body and basket body are full of water See priming instructions 2 Make sure there are no leaks in suction piping 3 Make sure suction inlet is well below the water level to prevent pump from sucking air 4 Pump is designed to prime at a vertical...

Page 7: ...tion and discharge piping are not adequately supported pump assembly will be strained See Installation 2 Do not mount the pump on a wooden platform Securely mount on a concrete platform for quietest performance before working on pump or motor ...

Page 8: ...which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to associated equipment cost of capital cost of substitute p...