background image

© 2009 Wayne Water Systems

330002-001 3/09

Sewage 

Pump

Operating Instructions and Parts Manual 

Models SEL40 and SEL50

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

Description

A sewage system consists of a pump, 
control switch, and a ba sin for use in 
ap pli ca tions where less than six toilets 
(units) are dis charged into the basin. 
The sys tem is generally con trolled by a 
float switch with a plug-in-plug which 
accepts the pump plug and in turn 
plugs into a 115 volt outlet.
The float switch is a wide angle 
differential switch that rises with the 
liquid level and turns the pump on. 
As the liquid level decreases the float 
lowers and turns the pump off. This 
pump is in tend ed for use in do mes tic 
sewage lift stations. It is suitable for 
pumping sewage, effluent, wastewater, 
groundwater and other non ex plo sive, 
non cor ro sive liquids with up to 2 inch 
solids.

For parts, product & service information

visit 

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!  

Attach it to this manual or file it for safekeeping.

 Specifications

  Power supply requirements .............. 115V, 60 hz
  Circuit requirements .......................... 15 amps (min)
  Motor duty ......................................... Intermittent
  Motor ................................................. 115V, 1 Phase, 1725 RPM
  Horsepower  ....................................... 4/10 (SEL40); 1/2 (SEL50)
  Motor full load .................................. 12 amps
  Liquid temperature range ................. 40º F to 120º F
  Max. operating position .................... 45º from vertical
  Dimensions ......................................... 13-1/2 inch x 11 inch
  Intake ................................................. 2 inch
  Discharge ............................................ 2 inch NPT female, 3 inch 

NPT male

  Cut-in level (factory set) .................... 18 inch
  Cut-out level (factory set) ................. 10 inch
  Differential ......................................... 8 inch
  Switch ................................................. 90º wide angle  

mechanical tether switch

  Power cord ......................................... 16 gauge 3 conductor  

w/plug

 Construction

  Motor body material ............Cold rolled steel
  Motor housing ......................Glass reinforced  

polypropylene

  Volute ....................................Glass reinforced ABS
  Impeller .................................Glass reinforced PBT
  Seal plate ..............................Cast Iron
  Shaft seal ...............................End faced mechanical

Performance

GALLONS PER hOuR At tOtAL hEAD IN fEEt

Model

10

15

200

SEL40

3700

1350

0

SEL50

6420

4200

1500

unpacking

Inspect this unit before it is used. 
Occasionally, products are damaged 
during shipment. If the pump or 
components are damaged, return 
the unit to the place of purchase for 
replacement. Failure to do so could 
result in serious injury or death.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates  

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.

 

Warning indicates  

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates  

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 
cause damage to equipment.

General Safety Information

CALIfORNIA PROPOSItION 65

 

This product or its  

  power cord contains 

chemicals known to the State of 
California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.

Summary of Contents for 330002-001

Page 1: ...0º F Max operating position 45º from vertical Dimensions 13 1 2 inch x 11 inch Intake 2 inch Discharge 2 inch NPT female 3 inch NPT male Cut in level factory set 18 inch Cut out level factory set 10 inch Differential 8 inch Switch 90º wide angle mechanical tether switch Power cord 16 gauge 3 conductor w plug Construction Motor body material Cold rolled steel Motor housing Glass reinforced polyprop...

Page 2: ...with pad locks master switch es and by re mov ing starter keys 10 When wiring an elec tri cal ly driven pump such as this fol low all electrical and safety codes as well as the most recent National Electrical Code NEC and the Oc cu pa tion al Safety and Health Act OSHA Risk of electric shock Never connect the green or green and yellow wire to a live terminal 11 This equipment is only for use on 12...

Page 3: ...e which will pass 2 inch solids or as required by state and local codes This gate valve permits removal of the pump and or check valve for servicing 5 A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping 6 The pump has a detachable tether switch with a piggyback plug see Figure 3 The length of the tether distance of cord f...

Page 4: ...4 Recheck all sizing calculations to determine proper pump size Pump shuts off and turns on independently of switch trips thermal overload protection 1 Excessive water temperature 2 Defective switch or entangled switch is causing pump to run dry 3 Low line voltage 1 Pump should not be used for water above 120º F 2 Replace or reposition pump Pump may start unexpectedly Disconnect power supply befor...

Page 5: ...Mechanical switch kit 60022 001 1 9 Oil plug 37303 001 1 Reference Number Description Part Number Quantity Repair Parts List For replacement parts or technical assistance call 1 800 237 0987 Please provide following information Model number Serial number if any Part description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45...

Page 6: ...me states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty ...

Page 7: ...de température du liquide 4 C à 49 C 40º F à 120º F Position de fonctionnement max 45º du vertical Dimensions 34 3 X 28 cm 13 1 2 po x 11 po Entrée 5 08 cm 2 po Décharge 5 08 cm 2 po NPT femelle 7 6 cm 3 po NPT mâle Niveau de démarrage réglé à l usine 45 7 cm 18 po Niveau d arrêt réglé à l usine 25 4 cm 10 po Différentiel 20 3 cm 8 po Interrupteur 90o mécanique à longe angle large Cordon d aliment...

Page 8: ... usage c Garder les visiteurs à une distance sûre de l endroit de travail Protéger l atelier pour les enfants avec des cadenas interrupteurs principals et en enlevant les clefs de démarrage 10 Pendant l installation de fils d une pompe électrique telle que celle ci suivre tous les codes de sécurité ainsi que les codes récents du National Electrical Code NEC et l Oc cu pa tion al Safety and Health ...

Page 9: ...dans le tuyau de décharge environ 1 à 2 po par dessus le décharge de la pompe lorsque vous utilisez un clapet Le trou empêche le blocage par l air de la pompe au départ initial et si elle perd l amorçage 4 Une vanne devrait être installée dans le système après le clapet La vanne devrait être de type à orifice plein qui passera des solides de 2 po ou selon les exigences des codes locaux et de la Pr...

Page 10: ...iquide soit au moins 33 02 cm 13po du fond du bassin La pompe se démarre et s arrête trop souvant 1 Refoulement d eau de la tuyauterie 2 Interrupteur flotteur défectueux 3 Clapet non installé ou qui a des fuites 4 Hauteur de décharge inférieur au minimum du fabricant 1 Installer un clapet 2 Remplacer l interrupteur flotteur 3 Enlever et examiner le clapet pour l installation correcte et le fonctio...

Page 11: ...tionnement libre 7 Ouvrir la soupape 1 Carter de moteur 28088 001 1 2 Cordon d alimentation 31026 001 1 3 8 16 x 1 po Vis 67112 001 6 4 Joint d étanchéité du carter 17456 002 1 5 Turbine 17317 001 1 6 Volute inclus 6 vis 23272 001 1 7 D huile Diélectrique 55932 2 2 pints 8 Trousse d interrupteur mécanique 60022 001 1 9 Bouchon d huile 37303 001 1 Numéro de Numéro Référence Description de pièce Qua...

Page 12: ...E SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variable d une Province ou d un État à l ...

Page 13: ...nsiones 34 3 X 28 cm 13 1 2 inch x 11 inch Orificio de Entrada 5 08 cm 2 inch Orificio de Salida 5 08 cm 2 inch NPT hembra 7 6 cm 3 inch NPT macho Nivel para encender fijado de fábrica 45 7 cm 18 inch Nivel para apagar fijado de fábrica 25 4 cm 10 inch Diferencial 20 3 cm 8 inch Interruptor interruptor mecánico de ángulo de 90º Cordón eléctrico calibre16 con 3 cables y enchufe Materiales de fabric...

Page 14: ... alejados del área de trabajo Cerciórese de tomar todas las medidas de seguridad necesarios para evitar accidentes con niños use candados y cortacircuitos y no deje las llaves al alcance de los niños 10 Para instalar el alambrado de bombas eléctricas tales como la descrita en este manual siga todos los códigos de seguridad laboral y electricidad establecidos en su país por ejemplo los de la NEC y ...

Page 15: ...ificio de descarga de la bomba Este orificio evita que el aire obstruya la bomba al encenderla por primera vez o cuando pierda el cebado 4 Debe instalar una válvula de entrada inmediatamente después de la válvula de chequeo Esta válvula debe permitir el paso de sólidos de 5 08 cm 2 inch o lo establecido por los códigos y ordenanzas locales Esta válvula le permite desconectar la bomba o la válvula ...

Page 16: ...a válvula de chequeo o la válvula de chequeo tiene una fuga 4 La distancia de la descarga es inferior al mínimo recomendado por el fabricante 1 Instale una válvula de chequeo 2 Reemplace el interruptor flotante 3 Desconecte la válvula de chequeo y revísela a ver si está bien instalada y funcionando adecuadamente 4 Haga los cálculos una vez más para cerciorarse de que esté usando una bomba adecuada...

Page 17: ... a ver si está bien instalada y funcionando adecuadamente 7 Abra la válvula 1 Cubierta del motor 28088 001 1 2 Cordón eléctrico 31026 001 1 3 Tornillo de 8 16 x 25 4 mm 1 inch 67112 001 6 4 Empaque cubierta del motor 17456 002 1 5 Impulsor 17317 001 1 6 Caja espiral incluye 6 tornillos 23272 001 1 7 Aceite dieléctrico 55932 2 2 pints 8 Juego de interruptor mecánico 60022 001 1 9 Tapón de aceite 37...

Page 18: ...OS Algunos estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada le otorga derechos legales especificos y usted también puede tener otros derechos que varian de un Estado a ot...

Page 19: ...Notes Notas Notes 19 SEL40 SEL50 ...

Page 20: ...Notes Notas Notes SEL40 SEL50 Operating Instructions and Parts Manual Instructions d Utilisation et Manual de Pièces Manual de Instrucciones de Operación y Piezas 20 ...

Reviews: