background image

 

Installing Washify Controller Integration 

 

Table of Contents. 

1.

 

Mounting the Enclosure

 

     Step 1. Metal Fins 
     Step 2. Lag Fins to the Wall 
     Step 3. Verify Mounting 

2. Providing Power and Network

 

     Step 1. Locate and Identify wire fittings 
     Step 2. Running Network/Cat Cable connection 
     Step 3. Tighten Network/Cat Cable fitting 
     Step 4. Terminate Network/Cat Cable 
     Step 5. Test Network/Cat cable 
     Step 6. Connecting Network Cable to Moxa 
     Step 7. Run power wires 
     Step 8. Insert power wires 

3. Wiring to controller

 

    Step 1. Run cables from 16 Keypad Push Button Station to Integration enclosure 
    Step 2. Insert Common Jumper strip 
    Step 3. Follow diagram to connect relays to 16 Keypad Push Button Station 
    Step 4. Connecting Adapter to ICS 16 Button Keypad 
    Step 5. Controller Code assignment 

 

 

 

 

 

 

 

 

Summary of Contents for MOXA

Page 1: ...ghten Network Cat Cable fitting Step 4 Terminate Network Cat Cable Step 5 Test Network Cat cable Step 6 Connecting Network Cable to Moxa Step 7 Run power wires Step 8 Insert power wires 3 Wiring to co...

Page 2: ...noise Electric Motors Electric Pumps Power Inverters 3 Less than 30ft of integration wiring between the enclosure and the ICS PBS Avoid running the ethernet cable near equipment that causes large lev...

Page 3: ...Step 1 1 Mount Metal mounting fins onto the enclosure with provided bolts...

Page 4: ...Step 1 2 Mount Box to wall using lag bolts or required hardware for wall type...

Page 5: ...Step 1 3 Verify Mounting is flush and will not fall...

Page 6: ...2 Providing power and a network connection Step 2 1 Locate and identify fittings for power and network cable take note of integration wiring fitting as it will be needed later...

Page 7: ...gration box Do not place the RJ45 plug on the cat cable until it has been run inside the fitting Remove the cap of the fitting run the cable through the cap then into the enclosure Leave enough slack...

Page 8: ...Step 2 3 Once the cable is inside the box screw the cap back on the fitting and tighten...

Page 9: ...able into a RJ45 end Make sure to follow T568B standard on both ends of the Cat cable You can find the standard in the image below Step 2 5 If a cable tester is available test the cable to verify all...

Page 10: ...Step 2 6 Insert the crimped RJ45 end into Port 1 on the Moxa box shown below...

Page 11: ...Step 2 7 Run power wire cables to the enclosure from a 120VAC power source Follow the same instructions as step 2 and 3 but for the power fitting...

Page 12: ...e fitting inside the enclosure Leave enough slack to work comfortably Tighten the cap over the fitting to seal the cable wires in place Step 2 8 Insert power cables into power terminal blocks Most AC...

Page 13: ...Black Line White Neutral Green Ground...

Page 14: ...d side 11 wires in total will be needed to completely integrate The best method is to source a 12 wire conductor 20AWG shielded Belden cable from a local supplier or online Shielded cabling is highly...

Page 15: ...e terminal jumper strip slides in Cut off the 2 jumpers on the right side this is being done to prevent relay 15 and 16 from having the Common terminals jumped Please Refer to the photo with the Jumpe...

Page 16: ...Check the next page for a photograph of the terminal strip connected...

Page 17: ......

Page 18: ...ll need to be completed before plugging the adapter into the ICS 16 Keypad Keep in mind that the wires should be run through the ICS 16 Keypad enclosure already Do not wire the adapter while the wires...

Page 19: ...tegration box Relay 9 Normally Open Adapter Terminal 10 connected to Integration box Relay 10 Normally Open Adapter Terminal 11 connected to Integration box Relay 11 Normally Open Integration Box Rela...

Page 20: ...n box Relay 8 Normally Open Adapter Terminal 9 connected to Integration box Relay 9 Normally Open Adapter Terminal 10 connected to Integration box Relay 10 Normally Open Adapter Terminal 11 connected...

Page 21: ...x Relay 16 Normally Open Integration Box Relay 4 Normally Open Jumped to Integration Box Relay 16 Common The purpose of the last 2 connections that are jumps inside the integration box is to allow was...

Page 22: ...he boards are separated Plug the adapter into the circuit board side as shown in the photos attached Next the Circuit board and adapter will need to be installed on the membrane the keypad faceplate P...

Page 23: ...shed in Once the adapter and circuit board are pushed in place you will need to install screws to secure the circuit board Take the screws that were removed to remove the circuit board and install the...

Page 24: ...S 16 button keypad Washify Integration box Step 3 5 Controller Code assignment The following diagram indicates the controller codes that need to be assigned for each service in Washify to trigger each...

Page 25: ...ons These buttons will only work if their specific integration method was used Method 1 Uses 16 for Sale function Stacking No roller integration with this method Method 2 Uses 16 for Roller function N...

Reviews: