background image

®

INSTALLATION MAINTENANCE 

& PRODUCT GUARANTEE

 WAGATE

®

 

GATE VALVES

PLEASE NOTE SERIAL/ORDERNUMBER HERE:

:

Summary of Contents for WAGATE SVM-TG125

Page 1: ... INSTALLATION MAINTENANCE PRODUCT GUARANTEE WAGATE GATE VALVES PLEASE NOTE SERIAL ORDERNUMBER HERE ...

Page 2: ... A WAPRO PRODUCT FOR FURTHER PRODUCT INFORMATION PLEASE REFER TO WAPRO COM INDEX SAFETY INSTRUCTIONS 3 TRANSPORT AND STORAGE 3 4 STORAGE 4 MOUNTING 5 8 COMMISSIONING 9 12 MAINTENANCE 13 MAINTENANCE INFORMATION 14 15 WARRANTY 15 ...

Page 3: ...ssioning for that product is carried out following that device s own specific operation instructions Please note that any actuator supplied by the manufacturer will not have been completely commissioned before shipping as the setup of electrical connection and communication interface can only be performed on site We recommend using a trained technician with knowledge of the chosen type of actuator...

Page 4: ...ndensation from damaging the circuit boards IDENTIFICATION Do not remove the label If purchasing spare parts state the size and type of valve Recommended solution Possible solution Is not recommended As for further information and measurements we refer to our product specifications VALVE APPLICATIONS The following table shows the applicable uses of each valve type as well as which types of operati...

Page 5: ...alve or on the inlet pipe follows the flow of the media Those valves designed for up and downstream pressure RVL and RVM TG series are bi directional and have no specified mounting direction When mounted the gate valve must not lean more than 45 degrees from vertical in any direction Violating this can result in reduced watertightness blockage of moving parts and permanent damage to the valve If a...

Page 6: ... fitted with any type of actuator the valve must be supported as described for larger sizes DN 355 NPS 14 and up Valves of these sizes are not self supporting and must be supported from beneath The flat contact patch on the bottom of the valve is made to be the main support point for the valve The pipes connected to the device must be completely self supported even when filled with water and can t...

Page 7: ...lve rated for 1bar of water pressure 10 meters of water pressure the max depth in ground is 5 meters A large series of extensions of operation are available for all models See general catalogue for options of contact Wapro When ordering note that the application is for in ground mounting MOUNTING ON WALL Valves can be manufactured with flanges for mounting directly onto both flat and curved walls ...

Page 8: ...nitial delivery Contact Wapro and provide valve type and size If a operation extension is used it is necessary to use wall brackets to eliminate excessive flexing The brackets should not be placed more than 1 5m apart AMBIENT CONDITIONS The device is rated for use in temperature between 25 C 40 C If the devise is used below freezing temperatures the buildup of stagnant water inside the valve is no...

Page 9: ...mmissioning the complete commissioning step in the operation manual specific to the actuator must be completed ELECTRICAL ACTUATOR The device can be equipped with different types of electrical actuators most commonly from the manufacturer AUMA The connection diagram for the actuator differs between different specifications of the actuator Therefore a connection diagram and complete manual is suppl...

Page 10: ...e valve If the valve is used in a setting with a lot of vibrations like near a road it is recommended to use a position lock to mechanically lock the valve in place Otherwise the vibrations can make the valve slowly close over time SVM TG RVM TG To close the valve turn the operating device clockwise until a natural resistance is met The valve opening is fully closed slightly before reaching the en...

Page 11: ...te the valve remotely the selector switch 5 is moved into the remote position The actuator will no longer react to the local controls and is controlled by the signals sent to it via its connection interface The precise details of these depend on the configuration of the actuator For more information on the connectivity and functionality of the actuator we refer to the specific operation instructio...

Page 12: ...r setup procedures The documentation can be found here https www linakthirdparty com products motor controllers and drivers wcu brochuresmanualsandbussetupfiles LOCAL ELECTRIC OPERATION To use the valve the controller has to be in the local operations mode activated by pressing the button 2 shown on the figure below Note that when in this mode remote controls are inactive and will only be activate...

Page 13: ...intenance must be performed for the product to operate as intended Failing to do so voids the warranty MAINTENANCE PLAN Every six months To check for proper function a full open close operation must be performed Long periods without use can cause the gaskets to get stuck in place The valve should operate smoothly and without sudden resistance Jerking motion is a sign of sticking gaskets Refill the...

Page 14: ...of the valve 4 Carefully remove the head from the valve Be careful not to damage the seals in the head when removing the head 5 Unscrew the spindle from the spindle nut only applicable to SVM TG RVM TG 6 If the gasket must be changed a thin piece of plastic has to be inserted into valve between the gate and the gasket before removing the gate Otherwise reinserting the gate is impossible without da...

Page 15: ...ve valves or subsequent installation of replacement valves Furthermore RiaWatech will not assume transportation costs of damaged valves or replacement valves RiaWatech warrants that repaired or replaced valves are covered for the greater of either the remainder of the original valve warranty or 90 days THE WARRANTY EXPRESSED ABOVE SHALL BE IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLU...

Page 16: ...Rev 1 0 CONTACT WAPRO customerservice wapro com wapro com SE 46 0 454 185 10 DK 45 64 82 40 00 US 1 888 927 8677 UK 44 114 308 0123 ...

Reviews: