background image

I n s t a l l a t i o n   a n d   O p e r a t i o n   M a n u a l  

FN8130GHPO 
FNL8130GHPO 

 

HPO Fast-Fri Gas Fryer 

Date Purchased 

Serial Number 

Dealer 

 

Service Provider 

 

228686-8 

Summary of Contents for FN8130GHPO

Page 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l FN8130GHPO FNL8130GHPO HPO Fast Fri Gas Fryer Date Purchased Serial Number Dealer Service Provider 228686 8...

Page 2: ...89 1007 Ph 09 574 3150 Fax 03 389 1276 Fax 09 574 3159 AUSTRALIA Victoria New South Wales Moffat Pty Limited Moffat Pty Limited 740 Springvale Road 3 142 James Ruse Drive Rose Hill Mulgrave Melbourne...

Page 3: ...anation of the Controls System Before Use Filling the Tank Pre Heating Lighting the Main Burners Setting the Operating Temperature Turning OFF the Fryer Frying Guide and Care of Frying Oils and Fats F...

Page 4: ...OWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR...

Page 5: ...changes in oil temperature which improves both recovery and output An open tank design to make cleaning a simple and easy task Optional Accessories This appliance can be fitted with the following opti...

Page 6: ...or and is entered from beneath the appliance An optional rear entry connec tion is available For all Appliance Options gas connection is 3 4 BSP male Electrical Supply Requirements Electrical connecti...

Page 7: ...5 Dimensions Dimensions FN L 8130GHPO...

Page 8: ...protected e g paint sealed by manufacturer are only allowed to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and tra...

Page 9: ...ssembly This model is delivered completely assembled Ensure that the legs are securely attached NOTE This appliance is fitted with adjustable feet to enable it to be positioned securely and level on u...

Page 10: ...rear roller to the rear leg housing and align the screw hole in the side of the rear leg housing with the threaded hole in the rear roller 4 Secure the rear roller to the leg support with the bolt su...

Page 11: ...kdown action of LPG must be used on every gas line connection unless compression fittings are used The connection to the appliance is 3 4 BSP male NOTE A Manual Isolation Valve must be fitted to the i...

Page 12: ...nstructions specified in the Operation section of this manual b The thermostat operation check should be carried out by filling the fryer with oil to the oil FILL LEVEL mark at the rear of the tank an...

Page 13: ...ms The fryer features an Over Temperature Safety Cut Out system with Full Flame Failure Safety Controls Snap action thermostat sensitive to changes in oil temperature Open tank design to simplify clea...

Page 14: ...ontrol will spark to re ignite the flame if the flame does not ignite the reset light on that side will show After operating the reset switch next to the main power switch behind the front door Refer...

Page 15: ...hot shortening is dangerous If pre melting of shortening is not possible then the shortening should be cut in pieces and packed down into the tank Bringing the shortening up to frying temperature when...

Page 16: ...Lock Out indicators illuminate press the left or right hand burner reset switches on either side of the main power switch to reset the control system for that burner Setting the Operating Temperature...

Page 17: ...6 With a little experience you can determine what amount of food may be added to the fryer without causing an excessive drop in temperature 7 If the temperature drop is excessive either the food is t...

Page 18: ...from the fryer after cleaning it f Taste the frying medium daily to be sure there is no Off flavour which may be transmitted to other foods If these simple precautions are taken consistently fried fo...

Page 19: ...valve c When the valve is closed the locking slide will drop down over the locking valve to prevent accidental opening of the valve as shown in Fig 6 Cleaning and Maintenance CAUTION Never drain the f...

Page 20: ...dle or small pan with a handle and dip into the hot frying medium from the receptacle and pour around the sides and bottom of the tank to wash out crumbs and particles adhering to the tank 10 Continue...

Page 21: ...deposits DO NOT use a wire brush as this will scratch the sides 6 Empty the fryer and rinse thoroughly with water Use a 1 part vinegar to 15 parts water solution to rinse the tank and neutralise any...

Page 22: ...oes are cured correctly Excessive quantities of breading or batter Remove surplus breading or batter Placing food in frying medium direct from the freezer Allow frozen foods to thaw before frying Surp...

Page 23: ...oil Check the setting of the thermostat with a mercury in glass thermometer or thermo couple Rapid breakdown of oil Use stable frying oil Use of unrefined oils Dripping smokes at lower temperature th...

Page 24: ...aving an active part in the control operation of the fryer and gives assistance to the most likely cause of failure should a fault develop The information provided should enable quick identification o...

Page 25: ...arth Faulty electronic control Is there sparking when the flame stops Power spikes Air pressure switch switching off Faulty flame rod connection Spikes on the earth Poor earth Check gas pressure Air p...

Page 26: ...0 P R O B E C O M N O RESET LH 29 48 YLW 2 1 30 RESET RH YLW 50 5 23 HEATING YLW 3 2 1 4 RED 6 RED RELAY 6 5 RED 8 7 18 31 O TEMP YLW 3 2 1 4 RED 32 YLW RELAY 6 5 RED 8 7 17 RED BLACK RED BLACK FUSE 2...

Page 27: ...connection 5 Remove the 3 screws securing the aeration plates to the side of the blower motors and replace with the correct plates Refer to Fig 10 Refer to the Gas Specifications Table shown at the en...

Page 28: ...ration section of this manual Light the Main Burners Check the Thermostat operation Ensure that all the controls operate correctly NOTE If for some reason it is not possible to get the unit to operate...

Page 29: ...27962 Power Indicator Green 013528 Lock Out Indicator Red 022449 Power Switch 020258 Reset Switch 016674 Relay Over Temp Switching 016674 Relay Heating Circuit 016673 Relay Base General 023220 Basket...

Page 30: ...28 Gas Conversion Kits Accessories 229674 Rear Roller Assy 228794 600 mm Fryer Plinth Kit Replacement Parts List Models Gas Type to Convert to Nat Gas G20 LPG Propane G31 All Models 022696 022695...

Page 31: ...29...

Page 32: ...30...

Reviews: