background image

INSTALLATION &

OPERATION MANUAL

FORM 35457 (10-09)

ELECTRIC
STATIONARY AND
TILTING KETTLES

MODEL

  MIL

K20EL

136073

K40EL

136074

K60EL

136075

K20ETL

136077

K40ELT

136078

K60ELT

136079

For additional information on Vulcan-Hart or to locate an authorized parts

and service provider in your area, visit our website at www.vulcanhart.com

VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM

3600 NORTH POINT BLVD.

BALTIMORE, MD 21222

60

30

30

150

120

90

0

Hg

vac

psi

K40EL

Summary of Contents for 136073

Page 1: ...TL 136077 K40ELT 136078 K60ELT 136079 For additional information on Vulcan Hart or to locate an authorized parts and service provider in your area visit our website at www vulcanhart com VULCAN HART D...

Page 2: ...UIPMENT WHO SHOULD PERFORM THE INITIAL FIELD START UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL Improper installation adjustment alteration service or maintenance can cause property dama...

Page 3: ...MINIMUM CLEARANCE REQUIREMENTS and RECOMMENDED FLOOR DRAIN LOCATIONS 6 INSTALLATION PROCEDURE 6 Electrical Connection 6 Electrical Specifications 6 OPERATION 8 VENTING 8 RESERVOIR JACKET WATER LEVEL C...

Page 4: ...carefully follow all of the instructions provided MODEL CHART Model Gallons Quarts Liters K20EL K20ELT 20 80 76 K40EL K40ELT 40 160 152 K60EL K60ELT 60 240 227 Fig 1 Typical Stationary Kettle INSTALLA...

Page 5: ...e shipment Immediately after unpacking check for possible shipping damage If kettle damage is found save the packaging material and contract the carrier within 15 days of delivery INSTALLATION CODES A...

Page 6: ...ts using the flanged feet 1 Place a spirit level on the rim of the kettle with the cover open Adjust the feet to level the kettle left to right and front to back 2 Mark anchoring hole locations throug...

Page 7: ...60EL ELT K40EL ELT 24 3 66 6 57 7 28 9 85 75 40 K60EL ELT K60EL ELT 33 3 91 6 79 4 39 7 115 100 50 ELECTRICAL CONNECTION Electrical and ground ing connections must comply with appli cable portions of...

Page 8: ...ld be placed into a cold kettle before cooking Avoid sudden contact of these food products to a hot kettle surface because they stick to the surface 3 Pour the food to be cooked into the kettle TILTIN...

Page 9: ...t and scrub the kettle interior with a nylon brush 4 Thoroughly rinse the interior and dry with a soft cloth 5 Rinse the exterior and dry with a soft cloth 2 3 COMPRESSION VALVE CLEANING INSTRUCTIONS...

Page 10: ...the ring has been overtightened Daily After Use Remove draw off valve plug for cleaning 1 Unscrew the retaining ring and remove it and the bottom washer 2 Pull the valve plug straight up to remove fr...

Page 11: ...ou live in you may have hard or soft water Hard water may leave spots and when heatedleavedepositsbehindthatiflefttosit will break down the passive layer and rust stainless steel Other deposits from f...

Page 12: ...ers and softeners whenever possible 6 Wipe off cleaning agent s and standing water as soon as possible Prolonged contact causes eventual problems To learn more about chloride stress corrosion and how...

Page 13: ...uld be analyzed to ensure that hardness is no greater than 2 0 grains per gallon and the pH level is within the range of 7 0 to 8 5 Water which fails to meet these standards should be treated or use i...

Page 14: ...level too low Add water Malfunctioning power ON OFF switch Contact Authorized Vulcan Hart Service Provider Malfunctioning thermostat Contact Authorized Vulcan Hart Service Provider Contactors not conn...

Page 15: ...act the Vulcan Hart Service Agency in your area refer to listing supplied with the steamer or contact the Vulcan Hart Service Department at the address or phone number shown on the front cover of this...

Page 16: ...16 ELECTRIC STATIONARY KETTLES 10 09 PRINTED IN U S A...