background image

01911

Surface electronic chronothermostat - Instruction handbook

CLIMA

PIÙ

Summary of Contents for 01911

Page 1: ...01911 Surface electronic chronothermostat Instruction handbook CLIMAPIÙ ...

Page 2: ...Space for noting the three digit PIN number used as the lockout password ...

Page 3: ...e Flat batteries and their renewal do not delete the programs or the settings after changing it will in fact be necessary to reset only the date and time In addition if the timer thermostat is not used for a long period of time it is always recommended to remove the batteries so as to prevent any acid leaking out that would damage the device For the battery life to be assured it is always necessar...

Page 4: ......

Page 5: ...pplication 6 5 Installation 6 6 Connections 8 7 Inserting changing the batteries 10 8 Button functions 11 9 Access to the menus and operating modes 13 10 Operation of the timer thermostat with the radio frequency module 28 11 Initial switch on 29 12 Main characteristics 30 13 Installation regulations 31 14 Conformity 31 ...

Page 6: ...peration during which it is also pos sible to change the programmed temperature temporarily The device is powered with two AA LR06 1 5 V penlight batteries that are easily found on the market and assure a power supply for the device for over a year 2 FRONT VIEW CONTROLS AND DISPLAY Indicators and controls 1 Room temperature 2 Unit of measurement of temperature 3 Day of the week 4 Month 5 Current t...

Page 7: ...for setting the temperature in corre spondence with Automatic operation N B If the display shows the symbol it means that the timer thermostat is switching on the heating likewise the symbol means that the timer thermostat is keeping the air conditioning on If the display does not show either of these two symbols it means that the heating or air conditioning is off at that time Figure 1 3 4 1 5 2 ...

Page 8: ...4 Figure 2 Figure 3 ...

Page 9: ...5 Figure 4 Figure 5 ...

Page 10: ...re day time system operating status and the daily profile set for the current program 5 INSTALLATION The appliance must be installed on a wall at a height of 1 5 m off the floor in a suitable position for correctly detecting the ambient tem perature It must not be installed in niches behind doors and curtains or in areas affected by sources of heat or atmospheric factors In particular it must not ...

Page 11: ...7 83 5 mm 60 mm Figure 6 ...

Page 12: ...8 L N U1 Motor operated valves 6 CONNECTIONS L N U1 Circulation pumps burners solenoid valves OPEN CLOSE Figure 7 Figure 8 ...

Page 13: ...ation and the keys are locked On opening the contact the timer thermostat is forced onto Antifreeze mode if heating is on OFF if air conditioning is on Note If the user has remotely forced timer thermostat operation onto Manual mode closing the contact to then be able to operate on the device it will be necessary to make another phone call to have the input contact open Connection to a telephone a...

Page 14: ...10 7 INSERTING CHANGING THE BATTERIES 1 AA LR6 1 5 V 2 ATTENTION After replacing the battery dispose of the old battery in the appropriate sorted refuse bins Figure 10 Figure 11 ...

Page 15: ...ode Manual Automatic OFF etc on quickly pressing the push button the device switches onto Manual if it was operating in a different mode switches onto the previously active mode if the timer thermostat was operating in Manual mode if it is on it deletes the automatic temperature change Pressing the selection button for approximately 4 s when the timer thermostat display shows the information relat...

Page 16: ... the device it is possible to set the desired temperature when the timer thermostat is on daily Automatic mode set the desired temperatures for each hour and for each day of the week while configuring the weekly automatic program Slider adjustment has immediate effect when the timer thermostat is working on daily Automatic mode if this is not the case there will be no change Take care that if the ...

Page 17: ...can be displayed by turning the knob OFF OFF TIMED ANTIFREEZ AUTO MANUAL MAN TIMED SETTINGS BACK After entering a menu if no operations are performed within a time of approximately 40 seconds the timer thermostat will exit this menu without saving any settings made in the meantime In all the menus selecting the BACK option will take you back to the previous display Note The SETTINGS menu is the me...

Page 18: ...ill no longer make any adjustment and the display will show 9 2 OFF TIMED This option permits switching off the timer thermostat for any length of time at the end of which the device will switch on going back into the previously active operating mode that is before switching off The OFF TIMED mode cannot be accessed if the timer thermo stat is working in OFF or MAN TIMED mode Access the main menu ...

Page 19: ...shows the screen corre sponding to the OFF TIMED mode that will remain active until 18th January at 11 30 a m after which the timer thermostat will switch over onto Manual mode The messages current date time and date time will appear alternate ly on the display as long as the OFF TIMED mode stays active Then press the selection button to confirm Note To exit the OFF TIMED mode quickly just briefly...

Page 20: ...Z the display will show Using the rotary knob set the desired antifreeze temperature this value can be set in the range from 4 C to 15 C in steps of 0 1 C Then press the selection button to confirm 9 4 AUTO In the AUTO operating mode that is automatic the timer thermostat performs temperature control both for heating and air conditioning by comparing the room temperature with the setting for each ...

Page 21: ...a diagram in which at the bottom there are the hours of the day from 0 to 23 vertically there are the corresponding temperature values that can be set with the sliders the heating values on the left hand side and the air conditioning values on the right hand side The following figure shows the display of the timer thermostat during AUTO operation in heating mode The automatic operating mode can be...

Page 22: ...ting or air conditioning 9 4 1 1 To access weekly programming the timer thermostat must be operating in weekly AUTO mode to activate this type of operation see par 9 7 3 After activating this mode open the front of the timer thermo stat using the rotary knob select MODIFY PROGRAM and press the selection button to confirm The display will show the current day for example MONDAY The CONCLUDE CHANGES...

Page 23: ... confirm the display shows the screen related to that day on which the temperature indicators will blink 9 4 1 3 At this stage the timer thermostat suggests the four differ ent options COPY MODIFY OTHER and CONCLUDE that can be selected with the rotary knob COPY is used for the following day to copy the same settings made for the current day that is the one that has just been set Press the selecti...

Page 24: ...matic program for Tuesday OTHER is used for a selected day to copy the same set tings made for the current day that is the one that has just been set After setting MONDAY press the selection button on OTHER and for example by selecting THURSDAY with the rotary knob the automatic program for Thursday will be the same as that for Monday CONCLUDE is used to exit programming Figure 21 Figure 22 ...

Page 25: ...s the program has a temperature near the current one differing by at most 1 C and will include the temperature values associated with these time bands in the change As soon as the device makes a change that does not come within the range of 1 C it will delimit the time band involved in this way the change can involve a minimum time band corresponding to the current time to reach a maximum time ban...

Page 26: ...he timer thermostat it is recommended to use MAN TIMED mode 9 5 MANUAL In this operating mode the timer thermostat works by comparing the room temperature with the one set by the user Access the main menu and press the selection button in cor respondence with MANUAL the display will show Using the rotary knob set the desired temperature this value can be set in the range from 5 C to 35 C in steps ...

Page 27: ...th MAN TIMED the display will show Using the rotary knob set the desired temperature that will be active for the time during which the timer thermostat works on manual Press the selection button to confirm Using the rotary knob set the desired time interval The value can be set in the range from 1 hour to 1 year in steps of one hour the first 6 hours are displayed as shown in figure 27 whereas aft...

Page 28: ... 20 5 C until 13th September at 20 50 after which the timer thermostat will switch over onto AUTO mode The messages current date time MAN TIMED and set point and date time will appear alternately on the display as long as the MAN TIMED mode stays active Figure 29 9 7 SETTINGS When the timer thermostat display shows the SETTINGS press the selection button this takes you to the following main menu w...

Page 29: ...s option is used to select the type of operation daily or weekly of the timer thermostat on AUTO automatic mode In the case of daily AUTO operation the timer thermostat adjusts the temperature using the settings made with the verti cal sliders whereas in the case of weekly AUTO operation the device sets the temperature according to the values selected in the phase of programming that correspond to...

Page 30: ...IF and using the rotary knob set the desired value can be selected between 0 1 C and 1 C lastly press the selection button to confirm 9 7 5 DATE TIME This option is used to set the current day and time on the timer thermostat Press the selection button on DATE TIME using the rotary knob set the day month year hours and minutes pressing the selection button to confirm each of the choices made see f...

Page 31: ...lection button on PIN using the rotary knob set the first second and third digit pressing the selection button to confirm each of the digits selected The PIN value 000 is equivalent to not setting the code for access ing timer thermostat use If the PIN code is lost and it is no longer possible to access the menus of the timer thermostat the device must be reset by following the instructions given ...

Page 32: ...or 01924 connected to the boiler or to the fan coil unit The option CONFIG RF is only displayed when the radio module 01921 1 has been inserted in the timer thermostat in place of the relay module this condition is shown on the display with the symbol displaying the symbol therefore indicates installation of the radio module 01921 1 and more generally the lack of the relay module Correct use of th...

Page 33: ...splay will again show the option CONFIG RF 11 INITIAL SWITCH ON When it is switched on for the first time the parameters of the timer thermostat 01911 are set as follows default settings Parameter Default valuet Unit of measurement of temperature C Time format 24 h Temperature differential 0 2 C Set point on MANUAL 20 C Set point on ANTIFREEZ 6 C AUTO program mode Daily Time interval for OFF TIMED...

Page 34: ...the rotary knob select RESET 12 MAIN CHARACTERISTICS Power supply 3 V d c with 2 penlight batteries AA LR6 1 5 V not provided Battery life over a year Output relay with clean changeover contact 5 2 A 250 V Type of setting ON OFF Possibility of radio frequency connection to actuators 01923 and 01924 after replacing the relay module with the transmitter module 01921 1 further information in the gene...

Page 35: ... of action 1CU Tracking index PTI175 State of pollution 2 normal Nominal pulse voltage 4000 V Ambient temperature during transport 25 C 60 C Operating temperature T40 0 C 40 C ErP classification Reg EU 811 2013 class I contribution 1 Software class A 13 INSTALLATION RULES Installation should be carried out observing current installation regulations for electrical systems in the country where the p...

Page 36: ...Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 39 0424 488 188 Fax Export 0424 488 709 www vimar com 01911IEN 01 1512 VIMAR Marostica Italy ...

Reviews: