manualshive.com logo in svg
background image

VIKING

VIKING BLUE ENABLED

SOLAR EFFICIENT OPERATION

installation instructions

class I, class II, class III, and class IV 

residential and commercial vehicular swing gate operator

and safety information

Содержание i-8

Страница 1: ...VIKING VIKING BLUE ENABLED SOLAR EFFICIENT OPERATION installation instructions class I class II class III and class IV residential and commercial vehicular swing gate operator and safety information...

Страница 2: ...s fulfilled with the i 8 gate operator The discreteness of the installation the flexibility of operation the efficiency of automation and the adaptability of integration makes the i 8 gate operator a...

Страница 3: ...I 8 Vehicular Gate Operator Revision B3 November 2009...

Страница 4: ...C 15 Optional Stainless Steel Casing and Cover I8CSSH 13 ECU Box VA ECUBB 14 Control Board Single Master Slave DUPCB10 I8 DUMSCB10 I8 15 Mounting Plate Single Master Slave ECUMPS10 ECUMPMS10 16 Toroid...

Страница 5: ...p 1 through 7 Operator Installation 13 Step 8 through 9 Limit Switch Setup 14 Opening Closing Setup 15 Reference Wiring Diagram Limit Switch Connections 15 Control Box Installation 16 Electrical Insta...

Страница 6: ...ONS 1 Install the gate operator only when a The operator is appropriate for the construction of the gate and the usage Class of the gate refer to page 5 b All openings of a horizontal slide gate are g...

Страница 7: ...e only Omron E3K R10K4 photoelectric eye to comply with UL325 10 For a gate operator utilizing a contact sensor Edge sensor or like in accordance with section 31 1 1 of the UL325 standard a One or mor...

Страница 8: ...carried out by qualified personnel In order to guarantee that the system works efficiently and correctly it is important to have the manufacturer s instructions on maintenance of the gate and operator...

Страница 9: ...ed via supervision by security personnel Install the gate operator only when The operator is appropriate for the construction of the gate and the Usage Class of the gate IMPORTANT SAFETY INFORMATION I...

Страница 10: ...tallation Secondary Entrapment Protection Photo beams or like must be installed to reduce the risk of entrapment Use only Omron E3K R10K4 photoelectric eye to comply with UL325 Make the electrical con...

Страница 11: ...sensor Installation Secondary Entrapment Protection Edge sensor or like must be installed to reduce the risk of entrapment Use only Miller Edge 3 sided activation type MGR20 or MDS20 to comply with U...

Страница 12: ...for 5 minutes or until a stop command gets actuated The Stop command can be actuated in two different forms 1 Using the Built in Stop switch on the Control Box or 2 Using an External Stop button withi...

Страница 13: ...a minimum height of 5 feet so small children are not able to reach it and 3 Away from all moving parts of the gate Maximum Gate Length 12 feet Maximum Gate Weight 650 lbs Maximum Aperture Angle 110 de...

Страница 14: ...13 46 16 61 STEP 1 Ensure the center of the Upper Hinge is 2 56 from mounting surface Weld in place If the hinge center is less than 2 56 form the surface clearance will have to cut into the lower mo...

Страница 15: ...the Gate Operator to an area drain Ensure that the pipe has proper slope to prevent any water accumulation in the operator or adjacent area STEP 7 Ensure the Gate Operator is level in both directions...

Страница 16: ...th the flats on the Gearhead STEP 11 Insert the Ball Bearing into the Intermediate Drive Arm lubricating it with silicone based grease Install the arm onto the Articulation Point of the Gate Operator...

Страница 17: ...15 Route the wires for the Gearmotor through the conduit already in place Connect the two wires to the wires coming from the Control Board The Wires are color coded Black to Black Blue to Blue STEP 13...

Страница 18: ...To adjust the open position stop Loosen the Open Position Adjustment Bolt Rotate the Open Position Stop so that it bumps against the Secondary Drive Arm at the desired position Rotating the Stop to m...

Страница 19: ...sitions 2 Allow the gate operator to run a full open and close cycle from stop to stop without interruption 3 Allow a complete cycle from limit to limit so the operator recognizes the limit settings O...

Страница 20: ...using the sealed washers provided place the rubber side of the washers against the inside of the control box Mounting Surface Control Box Sealed Washer Supplied with Unit Mounting Fastener Customer Su...

Страница 21: ...e proper position 115 for 110 to 120VAC 230 for 200 to 240VAC 3 Connect the incoming power wires to the terminals as shown in the illustration 4 Turn on the main switch or breaker once the installatio...

Страница 22: ...sor Hold Open Timer Stop Overlap Delay Close Open Obstruction Sensor min MAX Overlap Delay 1 5 0 3 Radio Station Safety Connector Open Commands Guard Station Master Slave GND Close Stop Open GND Close...

Страница 23: ...p Obstruction Sensor Charger Brake Fail Safe Secure Slave Fail Safe Secure Master Master Open Slave Open Master Slave Power Low Battery Slave Limit Open Limit Close Slave Limit Open Limit Close Hold O...

Страница 24: ...ide Re open Loop Exit Loop Make Even with Open Gate TECHNICAL SUPPORT 1 800 908 0884 20 VEHICULAR LOOP DETECTOR INSTALLATION VEHICULAR LOOP DETECTOR INSTALLATION Dimension A 5 for Single Gate Operator...

Страница 25: ...p detector unit in a way to minimize the effects of the gate over the loop detector wire IMPORTANT Some of the following parameters may affect the proper functionality of the vehicular loop detector c...

Страница 26: ...v Hold Open Timer Stop Close Open 30 60 Off 1 Brake Siren Exit Loop Detector Fire Override Keypad FIRE Safety Connections Radio Station Mag Lock Mag Lock Safety Connector Open Commands Guard Station M...

Страница 27: ...control the gate This type of configuration is not recommended for a commercial installations Open Only 2 By having the radio receiver connected as illustrated and with the Hold Open Timer ON see belo...

Страница 28: ...0 Mounting Plate Juction Box Mounting Plate Magnetic Lock Floating Plate M M 2 2 VIKING ELECTROMAGNETIC LOCK VIKING ELECTROMAGNETIC LOCK Standard Features Mounting base with electrical box 24VDC Plug...

Страница 29: ...NNECTIONS Radio Station Mag Lock Mag Lock Safety Connector Open Commands Guard Station Slave Radio Rec UL Sensor OPEN RIG OPEN LEF Safety Loop Center Loop Obstruction Sensor Charger Power Low Battery...

Страница 30: ...gate s movement and reverse it momentarily 2 Bring the gate to a resting position 3 Disable the Hold Open Timer feature until the Gate Operator receives a new command If another obstruction is detect...

Страница 31: ...Delay 1 5 Ce Lo Hold Open Timer Stop Close Open Limit Limit 30sec 60sec off 1sec 0 3 A Master Slave control board is required to operate two gates with a single controller Gate Overlap Setting Setting...

Страница 32: ...Timer Stop Close Open 30 60 Off 1 Radio Rec UL Sens Reopen Loop Center Loop Brake Siren JP3 C35 C36 The Auto Open feature in Viking Gate Operators enables the following functionality in the event of p...

Страница 33: ...l turn ON indicating the Control Board is ready for use with the Viking Blue Module 6 Open Viking Blue software on the chosen device If you are using the computer Hold the computer near the Gate Opera...

Страница 34: ...Motor Sensor Radio Station Loop Connector Gnd Reopen Gnd UL Gnd 28v Gnd Radio Gnd 28v 28v Mag Lock Fail Safe Secure MAG LOCK N C COM N O Charger Power Low Battery Check Motor Radio Rec UL Sens Reopen...

Страница 35: ...r Radio Rec UL Sensor OPEN RIGHT 24V BAT 24VAC OPEN LEFT Charger Power Low Battery Motor Sensor Radio Station ctor Mag Lock l cure MAG LOCK N C COM N O Charger Power Low Battery Check Motor Radio Rec...

Страница 36: ...d cables Check the voltage of the battery Gate does not run Obstruction sensor ON and audio alarm is SOUNDING Ensure that the gate path is clear of obstructions Note To stop the audio alarm use the st...

Страница 37: ...lose is set by the trim pot To turn this system off turn the trim pot all the way clockwise Gate opens in the opposite desired direction Verify your motor cable is connected to the proper connector Re...

Страница 38: ...earning algorithms redundancy design in both hardware and software to ensure operation and functionality protection from lightning short circuit and power surges and our exclusive helical gearing offe...

Страница 39: ...stop self adjust system Modulated speed regulator prevents exceeding operating speed that may reduce the service life of the gate operator and or installation Intelligent obstruction detection with ad...

Отзывы: