INSTALLATION AND OPERATION MANUAL

 

CE-(X)UTP

EThErnET-ovEr-UTP/TwisTEd Pair 

EXTEndEr wiTh Pass-ThroUgh PoE

The CE-(X)UTP Ethernet over UTP line consists of four models that support 100 Mbps 

Ethernet as well as pass-through Power over Ethernet (PoE) over twisted pair cable 

(CAT5, UTP). These models support transmission distances of up to 3,000 feet (914 m) 

at 10 Mbps, or 2,100 feet (640 m) at 100 Mbps. The CE-1UTP, the CE-4UTP, CE-8UTP 

and the CE-16UTP transport, one, four, eight or sixteen channels respectively. The  

IEEE 802.3-compliant Ethernet electrical interface of these Ethernet extenders also 

meets the requirements for IEEE 802.3af/at PoE power, passing-through up to 30 watts 

of power per port to the powered device (PD). The CE-(X)UTP series may also be used 

interchangeably with other Ethernet-over-UTP extenders. 

Environmentally hardened to the requirements of NEMA TS-1/TS-2 for most out-of-plant 

applications, and true plug-and-play design ensures ease of installation and operation.

LED indicators are provided for rapidly ascertaining the operating status of the device. 

See Figures 7 – 9 on page 6 for LED explanations.

Packaged in a rugged aluminum housing, these units are designed for desktop or stand-

alone mounting. The CE-8UTP and CE-16UTP are offered in EIA 19” 1U high rack for easy 

installation. See Figures A through C on page 7 for mounting instructions.

See Figures 1 – 8 for complete installation details. 

Important Safety Warning:

Read and keep these directions
Heed all warnings
Follow all instructions
Do not use this apparatus near water
Clean only with a dry cloth
Install in accordance with the 

manufacturer’s instructions
This installation should be made by a 

qualified service person and should conform 

to all local codes
See further safety instructions on page 8

Summary of Contents for CE UTP Series

Page 1: ...ngeably with other Ethernet over UTP extenders Environmentally hardened to the requirements of NEMA TS 1 TS 2 for most out of plant applications and true plug and play design ensures ease of installation and operation LED indicators are provided for rapidly ascertaining the operating status of the device See Figures 7 9 on page 6 for LED explanations Packaged in a rugged aluminum housing these uni...

Page 2: ... Page 2 CAT5 6 UTP CAT5 6 or UTP CAT5 6 CAT5 6 BLACK BLACK WITH WHITE STRIPE FIGURE 1 CE 1UTP FIGURE 3 CE 4UTP FIGURE 2 CE 1UTP INSTALLATION AND OPERATION MANUAL CE X UTP RIGHT PANEL LEFT PANEL LEFT PANEL Tech Support 800 34 VICON 800 348 4266 ...

Page 3: ...crew 12V Power Supply Ground Screw FIGURE 4 CE 8UTP FIGURE 5 CE 16UTP INSTALLATION AND OPERATION MANUAL CE X UTP Tech Support 800 34 VICON 800 348 4266 CAT5 6 or UTP CAT5 6 CAT5 6 or UTP CAT5 6 or UTP CAT5 6 CAT5 6 CAT5 6 or UTP CAT5 6 CAT5 6 or UTP CAT5 6 or UTP CAT5 6 CAT5 6 ...

Page 4: ... 4 Port Switch Extended over UTP or Coax NVR CE 16UTP PoE Switch 328 ft 100 m Cat 5 CE 4US1TPC IP Cameras IP Cameras 3 000 ft 914 m Cat 5 5 000 ft 1524 m Coax Managed High Power Midspan NVR CE 16IPS Switch Data Power Data Power CE 1UTP CE 1UTP CE 1UTP CE 1UTP PoE Camera PoE Camera CE 16UTP Single Port CopperLine over UTP NVR PoE Switch 3 000 ft 914 m Cat 5 328 ft 100 m Cat 5 CE 1UTP CE 1UTP PoE Ca...

Page 5: ...mera and the CE 1UTP Ethernet Switch NVR end Installation CE 1UTP Set the S2 Master Slave DIP switch to OFF for Slave mode Set the S1 and S3 DIP switches to match the setting on the camera end CE 4UTP CE 8UTP and CE 16UTP For each channel used set the appropriate dip switches for each channel to match the camera end Note Multichannel units are preset to Slave mode No adjustment required For system...

Page 6: ...E 8 EXTENDED LED INDICATORS FIGURE 9 ETHERNET LED INDICATORS POWER RED Power is on OFF Power is off TRAFFIC Extended 10 100BaseT GREEN Connection is OK 10BaseT mode YELLOW Flashing Traffic present RED Connection is OK 100BaseT mode OFF No traffic TRAFFIC Standard Link GREEN Flashing Connection is OK with traffic YELLOW Connection is OK OFF No connection No connection ...

Page 7: ...TP standalone module Figure C Dimensions are for the CE 8UTP and CE 16UTP modules 3 73 95 mm 3 6 92 mm 17 432 mm 1 6 40 mm 3 3 84 mm 1 6 40 mm 1 75 44 5 mm 3 25 82 5 mm 1 6 40 mm 1 15 30 mm Installation Considerations The CE 1UTP and CE 4UTP are supplied as standalone modules The CE 8UTP and CE 16UTP can be installed as standalone modules or can be rack mounted with the addition of the provided 19...

Page 8: ...ratus including DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel ...

Reviews: