background image

E

n

g

li

s

h

- 1 -

User manual memo DW E

Index

  Safety warnings 

page 

3

  Technical characteristics 

page 

3

  Dimensions 

page 

4

  Connection diagrams 

page 

4

  Display and keypad description 

page 

5

  Installation 

page 

6

 

Setting language 

page 

6

 

Setting date format 

page 

7

 

Setting date 

page 

7

 

Setting time 

page 

7

  Programmings 

page 

8

 

ON/OFF Events 

page 

8

 

IMPULSE Events 

page 

8

 

CYCLE Events 

page 

8

 

HOLIDAY Events 

page 

9

 

Programming priority 

page 

9

  Manual operation 

page 

10

 

Manual switching on/off 

page 

10

 

Casual switchings on/off 

page 

10

 

Lock output switchings (Lock) 

page 

10

 

Battery test 

page 

11

 

Menu Overview 

page 

12

  Automatic programming 

page 

13

 

Creation of a new programme 

page 

13

 

  Programmes ON/OFF 

page 

13

 

  IMPULSE Programmes 

page 

14

 

  CYCLE Programmes 

page 

16

 

  HOLIDAY Programmes 

page 

17

 

Checking a programme 

page 

19

 

  Displaying a programme 

page 

19

 

  Modifying a programme 

page 

20

 

  Deleting a programme 

page 

20

 

Reset programmes 

page 

21

  Settings menu 

page 

22

 

LANGUAGE menu 

page 

22

 

DATE menu 

page 

23

 

TIME menu 

page 

23

 

CHANGE CET/DST menu 

page 

23

 

CASUAL PARAMETERS menu 

page 

26

 

PROGRAMME OPTIONS menu 

page 

27

 

PIN menu 

page 

27

 

RESET SETTINGS menu 

page 

28

  Meter menu 

page 

29

  Reset menu 

page 

29

  Battery replacement 

page 

30

  Reference Standards 

page 

30

Summary of Contents for Memo DW E

Page 1: ...10 Lock output switchings Lock page 10 Battery test page 11 Menu Overview page 12 Automatic programming page 13 Creation of a new programme page 13 Programmes ON OFF page 13 IMPULSE Programmes page 1...

Page 2: ...able switches Large display with text guide to facilitate programming Sealable cover and possibility to lock keypad through password Time switch with daily weekly programming for the management of ele...

Page 3: ...nt must be installed and activated in compliance with current electric systems standards 6 Do not use the instrument for anything other than the indicated purpose Code Model Description VP871800 memo...

Page 4: ...English 4 User manual memo DW E DIMENSIONS CONNECTION DIAGRAMS...

Page 5: ...ock lock relay switchings f Field random programme g Field day of the week h Field programme running i Field CET DST j Field key functions Key activation menu esc check battery Key Ok confirm datum Ke...

Page 6: ...segments of the display will light for a few seconds and then the instrument shows the version of the firmware and the type of instrument At this point it is possible to insert the parameters necessar...

Page 7: ...s Use keys C1 and C2 to choose the desired value and press Ok to confirm and go on to the next parameter The sequence of parameters to be entered is year month day When the day is inserted also appear...

Page 8: ...and OFF events consist of switching the relay to the on or off position They may be daily every day at the same time or weekly one or more days during the week each week IMPULSE events An impulse even...

Page 9: ...rent events starting at the same moment the instrument will only run the one with the highest priority according to the following table 1 maximum priority Event Weekly Daily Cycle 1 Impulse 2 3 ON or...

Page 10: ...les the default minimum period is 1 minute and the maximum 5 minutes such values can in any case be changed in the settings menu Hold keys C1 and Ok down simultaneously for 3 seconds to activate the f...

Page 11: ...once a week Monday at 00 00 It is in any case possible to read battery status by holding down key for 3 seconds On the display appear the words if the battery charge level is sufficient for correct o...

Page 12: ...English 12 User manual memo DW E Menu Overview...

Page 13: ...menu choose the PROGRAM option using keys C1 and C2 and press Ok to confirm Choose option NEW using keys C1 and C2 and press Ok to confirm Using keys C1 and C2 choose the frequency of the event from D...

Page 14: ...ument activates the recursive function which allows several on off events to be programmed in succession on the same day Thereby once an activation deactivation event has been programmed it is possibl...

Page 15: ...Ok to confirm Choose the impulse using keys C1 and C2 and press Ok to confirm Using keys C1 and C2 choose whether it is an ON impulse or an OFF impulse Press Ok to confirm Se the date using keys C1 a...

Page 16: ...the words During normal operation the eventual execution of an impulse programme is shown by symbol on field 8 of the display 1 3 CYCLE Programmes Press key to enter the menu choose the PROGRAM optio...

Page 17: ...calculated so that the last period is always complete The maximum duration of a cycle is one week Press Ok to confirm Once programming is confirmed on the display appear the words During normal opera...

Page 18: ...the details of the interval are to be considered as included in the period As confirmation of programming on the display appear the words During normal operation the eventual execution of a holiday p...

Page 19: ...amme in the memory in order to enter a new one The message is shown on the display whenever there is an attempt to save a programme overwriting a pre existent programme of the same type for example tr...

Page 20: ...o insert the new programme parameters The parameter under modification flashes Use keys C1 and C2 to set the values and Ok to confirm or the key to exit without modifications At the end of the modific...

Page 21: ...e options modify delete and next to go to the next programme cycle At this point using keys C1 and C2 choose the desired option and press Ok to confirm 3 Reset programmes To delete all the programmes...

Page 22: ...ormal operational status press key choose SETTINGS using keys C1 and C2 press Ok to confirm LANGUAGE Menu choose SETTINGS LANGUAGE using keys C1 and C2 confirm with Ok the currently set language is di...

Page 23: ...display appear the words TIME Menu choose SETTINGS TIME using keys C1 and C2 confirm with Ok the current time displayed press Ok to access the modification enter hours and minutes using keys C1 and C2...

Page 24: ...ays to be set To set the days and the time in which CET DST time change occurs choose SETTINGS DAYL SAVE using keys C1 and C2 confirm with Ok The words AUTO ON appear on the display should this not ha...

Page 25: ...sen date the day of the month is requested in the other cases you are asked to enter the day of the week on which the time change is to happen Press Ok to confirm enter the time of the change Press Ok...

Page 26: ...the minimum and maximum time which passes between two switchings when a casual programme is activated As default these values are set at 1 and 5 minutes choose SETTINGS RANDOM using keys C1 and C2 con...

Page 27: ...roll the various types of programmings using keys C1 and C2 and press key Ok to access modification of the selected parameter once in modify choose keys C1 and C2 if you want to enable or disable the...

Page 28: ...de To unlock the instrument simply enter the pin code according to this rule key 1 key C1 2 key C2 3 key Ok 4 For example pin 3411 C2 Ok RESET SETTINGS Menu This option resets all settings relative to...

Page 29: ...ble to restore the initial status of the instrument using the reset function 4 different resets are available reset settings cancel all the entered settings reset programmes cancel all the saved progr...

Page 30: ...unt the cover turning it clockwise connect the power supply In order not to lose programming and the performed settings it is necessary to make sure that no more than 60 seconds pass between extractin...

Page 31: ...sofinactivityofthekeyboard Code Model Description Powersupply VE462800 MemoDWE Timeswitchdaily weekly1relay 12Vac dc VE463600 MemoDWE Timeswitchdaily weekly1relay 24Vac dc TECHNICALINFORMATION GENERAL...

Reviews: