background image

VECTOR 

FOG� 

USER MANUAL 

ULV FOGGER 

C20, C100 Plus, C150 Plus 

© 

2020

  Vectorfog is a trademark of Vectornate Ltd. 

Summary of Contents for VECTOR FOG C20

Page 1: ...VECTOR FOG USER MANUAL ULV FOGGER C20 C100 Plus C150 Plus 2020 Vectorfog is a trademark of Vectornate Ltd ...

Page 2: ...lace the fuse please use a 15 amp fuse with the correct voltage Failure to use the right fuse could cause an electrical fault or motor to overheat The fuse is located above the power cords female coupler FUSE Do not move the fogger by pulling it by the power cord Unplug from power supply when not in use and before servicing or cleaning Do not operate with a damaged cord or plug after a malfunction...

Page 3: ...02 PRODUCT OVERVIEW for 10 minutes ...

Page 4: ...nular or viscous in nature doing so will damage the machine and void the warranty Pre mix the chemicals prior to filling the tank Mix the chemicals according to manufacturer s instructions Do not overfill the tank Close the tank cap firmly making sure an air tight seal is achieved Not closing it firmly could affect the machine s performance 3 ...

Page 5: ......

Page 6: ...l get rid of any existing liquid remaining in the fogger s internal tubes STEP B Fill the fogger with some clean water and operate again for one minute Remove any excess water from the tank Cleanup of emulsions After fogging begin with STEP A Then fill with appropriate solvent for the chemical that was used and operate unit for 1 minute flushing any residual chemical left inside Then repeat STEP B...

Page 7: ... 1 2 ...

Page 8: ...7 P C B S w i t c h A s s y 7 1 P C B 1 8 P o w e r C a b l e 7 2 S w i t c h A s s y ...

Page 9: ...4 8 0 x 2 0 0 x 2 5 0 mm 2 L 5 2 5 x 1 6 5 x 3 0 5 mm 6 3 0 x 1 9 5 x 3 1 0 mm ...

Page 10: ... approved for acid resistance a Ph value should be limited from 4 5 8 5 After use fog with some clean water for about 3 minutes to remove any chemicals still left in the system Ensure all the water is used up and the machine is dried prior to storage Damage caused by corrosion due to humidity by wrongful storage will invalidate this guarantee Any formation of aerosols or fogs from flammable substa...

Page 11: ...ne is not for fogging any powder based solutions these can cause blockages and damage to the machine Only use solutions between the pH levels of 3 and 10 3 Please do not lay the machine on the left side right side or upside down Always keep the machine upright If not the solution might flow into the motor area and cause a short circuit which shortens the lifespan of the motor 10 ...

Page 12: ...T E L U K 4 42 03 8 0 85 7 9 7 K O R E A 8 2 0 7 04 6 9 42 4 8 9 U S 12 0 14 8 29 8 3 5 E ma i l i n f o v e c t o r f o g c o m ...

Reviews: