background image

ASSEMBLY  AND  INSTALLATION 

                INSTRUCTIONS

T0730 / T0731

Maximum Wattage: 60W Bulb

                                  

Working Temperature: -22°F~113°F 

1. Read all instructions carefully before installation and

    operation. 

2. If you are not familiar with state and local electrical codes,

    it is recommended that you consult with a qualified

    electrician. 

3. Before installation, shut off power at the main fuse or 

    circuit breaker box. Be aware that simply turning off the

    wall switch is not sufficient to prevent an electrical shock.

4. This fixture requires a 120V AC, 60 Hz power source. 

5. Do not attempt to take the lantern apart; there are no

    serviceable parts inside. 

6. To avoid sensor damage by lightning or electrical surge,

    make sure the ground wire is securely connected. 

7. For general safety and to avoid any possible damage to

    the sensor, be sure the power is switched "off" before

    replacing the bulb.

8. Compatible with most LED dimmable bulbs.

 

 

 

Hardware Package (included)

Important to Know

Features

 

WARNING: Turn off the main power at circuit breaker before installing fixture.

NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.

            2. Read

 and save these instructions.

Page 1 / 5

1. Energy saving fixture.

2. When in manual override mode, use wall switch

    to keep the light ON till dawn.

Mounting Screw (B)

Wire Connector (C)

Bolt Nut (D)

Crossbar Unit (A)

Rubber Pad (E)

Backplate

Wire Connector (C)

House Ground Wire

Outlet Box

Mounting Screw (B)

Fixture Mounting Screw

Green Ground Screw

Rubber Pads (E)

Bolt Nut (D)

Crossbar Unit (A)

Fixture Wire

Fixture Ground Wire

Fixture

       

Max. 60W Type A Bulb 

     (not included)

231020

Summary of Contents for T0730

Page 1: ...ground wire is securely connected 7 For general safety and to avoid any possible damage to the sensor be sure the power is switched off before replacing the bulb 8 Compatible with most LED dimmable bu...

Page 2: ...rew then depending on local code connect it to the house ground wire with the wire connector C Carefully put all of the wires back into the outlet box 4 Attach the backplate of the fixture to the cros...

Page 3: ...peration only The light will turn on automatically at dusk and turn off at dawn Auto Mode Off Mode Manual Override Manual Override Operation Diagram Turn wall switch OFF ON in 0 5 3 Seconds Turn wall...

Page 4: ...Motion Motion 150 TROUBLESHOOTING Refer to following information to solve your problems Set the rotary knob in the test mode for testing Night If the light isn t on SYMPTOM DAY NIGHT POSSIBLE CAUSE SO...

Page 5: ...t suited for the products intended use operation in temperatures outside of the range specified in the instruction manual usage with improper power supply power surges or dips For coastal locations so...

Page 6: ...ra del artefacto Artefacto Bombilla tipo A de 60 W como m ximo no incluida 231020 INSTRUCCIONES DE ENSAMBLAJE E INSTALACI N Vataje m ximo bombilla de 60 W Temperatura de funcionamiento 22 F 113 F 1 Le...

Page 7: ...igo local con ctelo al cable de descarga a tierra de la casa con el conector de cable C Vuelva a colocar con cuidado todos los cables en la caja de toma de corriente 4 Adjunte la placa posterior del a...

Page 8: ...Diagrama de funcionamiento de desactivaci n manual Apague Encienda el interruptor de pared en 0 5 3 segundos Apague Encienda el interruptor de pared en 0 5 3 segundos Fig 4 5 MODO de desactivaci n man...

Page 9: ...ver los problemas 231020 Coloque la perilla rotatoria en el modo de prueba para comprobar el funcionamiento Noche Si la luz no est encendida S NTOMA D A NOCHE POSIBLE CAUSA SOLUCI N D a La perilla rot...

Page 10: ...servicio de garant a info vaxcel com 1 800 482 9235 Vaxcel ofrece una garant a de un a o en todos sus productos contra defectos de fabricaci n y acabado a partir de la fecha de env o Adem s Cualquier...

Page 11: ...W Type A non incluse 231020 INSTRUCTIONS DE MONTAGE ET D INSTALLATION Puissance maximale Ampoule 60 W Temp rature de fonctionnement 30 C 45 C 22 F 113 F 1 Lisez attentivement toutes les instructions...

Page 12: ...re de la maison l aide du connecteur de fil C Remettez soigneusement tous les fils dans la bo te de sortie 4 Fixez la plaque arri re du luminaire l unit de barre transversale A en ins rant les vis de...

Page 13: ...ode Auto Mode Off Arr t manuel Sch ma de fonctionnement de la commande Arr t manuel teignez allumez l interrupteur mural en 0 5 3 secondes teignez allumez l interrupteur mural en 0 5 3 secondes Fig 4...

Page 14: ...sibilit minimale Sensibilit maximale D tecteur Fig 8 Mouvement Mouvement 150 R SOLUTION DES PROBL MES Reportez vous aux informations suivantes pour r soudre vos probl mes 231020 Placer le bouton rotat...

Page 15: ...tous ses produits contre les d fauts de fabrication et de finition pendant un an compter de la date d exp dition En outre Tout produit dot d un d tecteur de mouvement int gr ou d une cellule photo le...