               2. READ AND SAVE THESE INSTRUCTIONS.

T0481

WARNING:

TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF

POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.

Hardware Package (included):

Turn off the power at fuse or circuit box

Turn on the power at fuse or circuit box

Installation Steps

181210

 

 

1. Unscrew the finial and the rubber pad on the upper cover. 

2. Unscrew set screws and remove the threaded pipe and iron 

    plate from the metal frame.

3. Gently place four glass panels into the metal frame,

    then press the clips to secure the glass panels. (Fig.1) 

 

 

 

1.  Unscrew the finial and the rubber pads on the upper cover. 

2. Unscrew set screws remove the threaded pipe and iron plate

    from the metal frame.

3. Gently place four glass panels into the metal frame,

    then press the clips to secure the glass panels.

    (Fig.1) 

4. Attach the candle tubes onto the sockets. 

5. Install three bulbs (not included). See relamping label 

    at socket area or packaging for maximum allowed wattage.

6. Pull out the wires and grounding wire from the 

    post. Make wire connections using the wire 

    connectors (B):

    ---The black wire from the fixture to the black 

        wire from the post.

    ---The white wire from the fixture to the white

        wire from the post.

    ---The grounding wire from the fixture to the 

        grounding wire from the post.

        Carefully put the wires back into the post.

7. Place the fitter on the post, then secure it with the fitter screws (A).

    

CAUTION: With silicone caulking compound, caulk completely around where the fitter meets with the post 

    surface to prevent water from seeping into the post.

Wire Connector (B)

Fitter Screw (A)

Fig.1

Glass Panel 

Clip

Metal 

Frame 

Bulb Type B Max.60W

       (not included)

Metal Frame

Socket

Candle Tube

Iron Plate

Set Screw

Threaded Pipe

Glass Panel 

Rubber Pad

Upper Cover

Finial

Grounding Wire

Fixture Wire

 

Wire Connector (B)

 

Post

Fitter

Photocell

Fitter Screw (A)

4. Attach the candle tubes onto the sockets. 

5. Install three bulbs (not included). See relamping label 

    at socket area or packaging for maximum allowed wattage.

6. Pull out the wires and grounding wire from the post. 

    Make wire connections using the wire connectors (B):

    ---The black wire from the fixture to the black wire from the post.

    ---The white wire from the fixture to the white wire from the post.

    ---The grounding wire from the fixture to the grounding wire from the post.

    Carefully put the wires back into the post.

7. Place the fitter on the post, then secure it with the fitter screws (A).

    

CAUTION: With silicone caulking compound, caulk completely around where the fitter meets with the post 

    surface to prevent water from seeping into the post.