PATHLIGHT
LED LUMINAIRE SSL1, ISL1, ISL2 & BOLLARDS
Luminaires require factory-supplied
24-Volt DC power supply, specified
separately. Integral and remote
mounted power supply options
available. Secondary run lengths
dependant of selected power supply.
Fixtures supplied with 6” lead of 18
gauge wire.
This product must be installed in
accordance with applicable electrical
and installation codes by a person
familiar with the construction and
operation of the product and the
hazards involved. “CAUTION– RISK OF
FIRE”
I N S T A L L A T I O N
Before beginning any pathlight
installation, disconnect electrical power
at main switch or circuit breaker.
To reduce the risk of fire, electric shock,
and potential damage to recessed
housing assembly when electrical power
is re-connected, DO NOT ATTEMPT TO
CONNECT the following on branch circuit
serving pathlight assembly:
CAUTION
•Motors •Power tools •Extension cords
•Appliances or similar electronics
A.
Fixtures to be mounted in conditions where
ambient temperatures do not exceed 40°C.
Ensure AC input voltage is protected against
surges & load shifts prior to power supply
input.
SAFETY INSTRUCTIONS
B.
Read installation instructions
completely before attempting
installation.
Failure to follow instructions may
result in improper installation and
void warranty.
Contact Lucifer Lighting Company
with any questions or concerns
before beginning any installation.
Ensure qualified electrician will
perform all electrical procedures.
Disconnect electrical power
circuit before attempting to install
pathlight or power supply.
1
Pathlights are Class II LED luminaires
for discreet path lighting for
residential, commercial and hospitality
applications. Durable precision milled
316 stainless steel or brass casting.
C.
E.
DESCRIPTION
POWER
Optimum 18” (457mm) above walking
surface; 36” (915mm) on-center
spacing for SSL1 & ISL1; 60” (1524mm)
on-center spacing for ISL2 .
D. RECOMMENDED SPACING
1.
2.
3.
4.
5.