background image

ETC101 (Top Performer Control) 

Installation Manual 

 
 

Installation  

WARNING: Do Not Use With 110V circuits. For Switching 110V, use a standard TPI Control.

 

 

 

 

 

 

 

  

 

            

      

ETC101       Insulation   Tank

 

         Screw A 

Attaching ETC101 to Top Performer tank: 

 

Place ETC101 so that temperature sensor lead goes through the hole in back.  
ETC101 should fit flush against the tank jacket. 
Use self-tapping screw provided (Screw A) to attach ETC101 directly to the 
Top Performer.  

Attaching ETC101 to tanks with immersion wells: 

Place hole in back of ETC101 over immersion well. (See Diagram 1) 
If ETC101 can fit flush against the tank without the immersion well protruding 
beyond the top of the ETC101 case, the ETC101 can be mounted as described 
above. Otherwise, the ETC101 can be mounted directly onto the immersion 
well itself. 
Place square nut in the retaining well on the ETC101 box. 
Use proper machine screw provided (Screw B or Screw C) to tighten against the immersion well. 

Inserting the Temperature Sensor: 

Connect the probe to the ETC101 by inserting the leads in the black opennings on top of the probe connector 
while pushing both white buttons with finger nail or a tool (such as a screwdriver). This can also be done one 
side at a time. Release the white buttons and pull on each probe lead to check connection. See Diagram 5. 
For tanks with integral probe, the sensor installation is complete. 

 

For tanks with an immersion well, slide temperature sensor all the way into the immersion well – until it 
contacts the end. (See Diagram 1) 
The sensor will measure temperature adequately by resting against the bottom of the immersion well.  
(Note: Sensor does NOT need to make intimate contact with entire well surface to work properly) 

Wiring the ETC101:

  

ETC101 is rated 24VAC, 1 Amp Resistive. 

WARNING: Do Not Use With 110V circuits. For Switching 110V, use a standard TPI Control. 

Run all 24VAC wiring thru the square notch on bottom of ETC101 case. (See Diagram 3) 
Connect thermostat wiring to the TT connectors on the bottom left corner of the ETC101. (See Diagram 3) 

 

For controlling zone valves, multi-zone controllers and switching relays, follow applicable wiring diagrams for 
low voltage thermostat circuits.  (See Diagram 2) 
 

For Newer Switching Relays: Some models don’t work with “Power Stealing” thermostats. The ETC101 
is a power stealing thermostat (using only the TT terminals) unless powered separately (using the 24V 
terminals). Connect 24VAC Power (From the the switching relay board (See manual for that product for 
details) or from a step down transformer to the screws to the right of the Probe Connector. 

 

Summary of Contents for ETC101

Page 1: ...one one side at a time Release the white buttons and pull on each probe lead to check connection See Diagram 5 For tanks with integral probe the sensor installation is complete For tanks with an immersion well slide temperature sensor all the way into the immersion well until it contacts the end See Diagram 1 The sensor will measure temperature adequately by resting against the bottom of the immer...

Page 2: ...RECOMMENDED you must remove the SCALD DANGER label attached to the temperature slide WATER TEMPERATURE REGULATION WARNING Exposure to 125 F or hotter water can cause scalding injuries Appropriate caution must be taken when using hot water Special supervision must be given to those who cannot act quickly such as children invalids or elderly persons The input of heat into the tank is controlled by a...

Page 3: ...omes with a factory set differential setting of 10 This means that the ETC101 will call for heat when the tank temperature has fallen to10 degrees below the Temperature set point To adjust the differential setting slide the lever to the desired setting using the indicator scale Diagram 1 For tanks with Immersion Wells Diagram 2 Typical Wiring Wiring with 24V if needed Diagram 3 ...

Page 4: ... black holes in top of connector This can also be done one side at a time 5 C Tug on each wire to make sure they don t move easily 5 A Buttons up 5 B Buttons down Wires pushed down 5 C Buttons up Wires tight Wires Buttons Revision 1 1 Indicating Light Temperature Adjust Differential Adjust TT Connection Screws Probe Connector Optional 24V Power Connection Screws ...

Reviews: