background image

 

 

 
 
 
 
 

 

 

 
 
 
 
 

 

Instructions of use and maintenance page 2 

Electric and refrigerating diagrams page 3 

Manual of the thermostat page 4 - 6 

Spare parts page 7 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Rue Charles Hermite Z.I. des Sables BP 59 

54110 Dombasle sur Meurthe France 

tel : (+33) 03 83 45 82 82 - fax : (+33) 03 83 45 82 93 

e-mail : [email protected]  

[email protected]

 

REVERSO

Summary of Contents for REVERSO

Page 1: ...igerating diagrams page 3 Manual of the thermostat page 4 6 Spare parts page 7 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com REVERSO ...

Page 2: ...ing the standard of unit the twist of the self evaporating tray can be situed in the face or in the back of the unit Astainless steel sheet deflector located in the self evaporating tray allow to direct the water vapour The sheet must be located in the middle of the self evaporating tray the same distance in each side The deflector must be located to have the good direction of the inclination like...

Page 3: ...ter Cd Condensor Sn Level probe D Relief valve St Atmosphere temperature probe Dh Drier Tb Safety thermostat for self evaporating tray E Evaporator Tf Fluorescent tub I 4 positions switch Tr Thermostat XR40 Kb Self evaporating tray relay Ts Safety Thermostat Kd Defrost relay V Well ventilator Lh Halogen lamp Va Variator Q Fuse holder Vc Condensor fan R Heating element ...

Page 4: ...ed At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the following table...

Page 5: ...t message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery Probe alarms P1 probe1 faulty P2 they automatically stop 10s after the probe restarts normal operation Check connections before replacing the probe Temperatu...

Page 6: ...ital input ON ALARM signal In Pr2 indicates the parameter is also present in Pr1 3 2 To see the set point Push and release the SET key to see the Set point value To come back to the normal display push again the SET key or wait 10s 3 3 To change the set point Hold pushed the SET key for 3s to change the Set point value The value of the set point will be displayed and the LED1 2 start blinking To c...

Page 7: ...stance with blades length 625 mm power 1250 W X 12 2518 Evaporator length 580 X 12 2520 Evaporator length 900 X 12 2522 Evaporator length 1230 X 12 2524 Evaporator length 1550 X Option crawl heating halogen 06 0622 Halogen lamp power 200W X X X X 06 0620 Aluminium reflector X X X X 06 0625 Protective glass fixing X X X X 06 1520 Variator X X X X Lighting 06 1005 Orange indicator switch X X X X 06 ...

Reviews: