background image

This manual provides information on 
Installation, operating, maintenance, 
trouble shooting & replacement parts for

CURVED GLASS
DISPLAY CASE

OPERATORS MANUAL

NOTIFY CARRIER OF DAMAGE AT ONCE.

It is the responsibility of the consignee to inspect the 
container  upon  receipt  of  same  and  to  determine 
the possibility of any damage, including concealed 
damage.  Randell  suggests  that  if  you  are  suspi-
cious of damage to make a notation on the delivery 
receipt. It will be the responsibility of the consignee 
to file a claim with the carrier. We recommend that 
you do so at once.

OMANUAL_CGDC-8/23/04

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

randell.com

Information  contained  in  this  document  is  known  to  be 

current  and  accurate  at  the  time  of  printing/creation.  

Unified Brands recommends referencing our product line 

websites, unifiedbrands.net, for the most updated product 

information and specifications.

Summary of Contents for 4137REA

Page 1: ...uggests that if you are suspi cious of damage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so at once OMANUAL_CGDC 8 23 04 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 fax 888 864 7636 randell com Information contained in this document is known to be current and accurate at the time of ...

Page 2: ...nance will provide years of trouble free service to its owner Always Disconnect power cord before attempting to work on or to clean equipment Turning the switch off is insufficient as the power remains live to the cabinet and can be a hazard Route the power cord so that it is not likely to be walked on or pinched by other appliances Your unit is equipped with a grounded plug a plug with 2 blades a...

Page 3: ...tire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied MODEL NUMBER SERIAL NUMBER INSTALLATION DATE In addition all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians Retain this manual for future reference 3 randell com ...

Page 4: ... call our Field Service Department at 1 888 994 7636 Warranty Policies The serial number is located inside the display case cabinet Service and Parts Hotline 800 621 8560 Randell Manufacturing Service and Parts Hotline WHEN OPTIONAL 5 YEAR COMPRESSOR WARRANTY APPLIES Randell will provide to the original customer that owns a Randell piece of equipment and has an optional compressor warranty with on...

Page 5: ...ar or 21 months to 2 calendar years from date of purchase Please contact Randell Manufacturing s technical service hotline at 1 800 621 8560 for details and warranty authorization numbers Warranty Policies continued 1 Randell Manufacturing covers all non electrical components under the same guide lines as our standard domestic policy 2 All electrical components operated on 60 cycle power are cover...

Page 6: ...igned for by the truck driver Appearance of damage will require removing the crate in the presence of the driver Consignee is responsible for filing of freight claims when a clear delivery receipt is signed Claims for damages must be filed immediately within 10 days by the con signee with the freight carrier Retain all cartons and merchandise for inspection Authorization for return must first be o...

Page 7: ...S SELF CONTAINED 4100SCA Model L D H Display area shelves sq ft HP NEMA VOLT SHIP WT 4137SCA 37 34 5 46 16 2 1 3 5 15P 115 500 4149SCA 49 34 5 46 22 6 3 8 5 15P 115 560 4161SCA 61 34 5 46 29 1 2 5 15P 115 675 4173SCA 73 34 5 46 35 2 1 2 5 20P 115 805 ...

Page 8: ... GLASS REMOTE 4100REA Model L D H Display area shelves sq ft HP NEMA VOLT SHIP WT 4137REA 37 34 5 46 16 2 1 3 5 15P 115 500 4149REA 49 34 5 46 22 6 3 8 5 15P 115 560 4161REA 61 34 5 46 29 1 2 5 15P 115 675 4173REA 73 34 5 46 35 2 1 2 5 20P 115 805 ...

Page 9: ... SPECIFICATIONS FOR CURVED GLASS AMBIENT 4100DR Model L D H Display area shelves sq ft HP SHIP WT 4137DR 37 34 5 46 16 2 1 3 400 4149DR 49 34 5 46 22 6 3 8 460 4161DR 61 34 5 46 29 1 2 475 4173DR 73 34 5 46 35 2 1 2 605 ...

Page 10: ...10 888 994 7636 UNIT SPECIFICATIONS FOR CURVED GLASS DUAL TEMP 4100DT Model L D H Display area shelves sq ft HP SHIP WT 4137DT 37 35 46 5 16 2 1 3 500 4149DT 49 35 46 5 24 3 3 8 560 ...

Page 11: ...ers steam kettles etc and out of direct sunlight Avoid locating the make table in an ungrated room or where the room temperature may drop below 55 F or above 90 F The wiring should be done by a qualified electrician in accordance with local electrical codes A properly wired and grounded outlet will assure proper operation Please consult the data plate attached to the compressor to ascertain the co...

Page 12: ... that unit is holding temperature Set controls to desired temperature for your particular ambient and altitude 7 Allow your display merchandiser to operate for approximately 2 hours before putting in food This allows interior to cool down to the correct storage temperature NOTE All motors are oiled and sealed After installing unit in final location make sure counter surface is clean and seal aroun...

Page 13: ...nser coils Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer Failure to maintain this heat transfer will affect unit performance and eventually destroy the compressor Clean the condenser coils with coil cleaner and or a vacuum cleaner and brush NOTE Brush coil in direction of fins normally vertically as to not d...

Page 14: ...DROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can often catch and repair minor problems before they completely disable the unit and become burdensome on your entire operation For more information on preventive maintenance consult your local service com pany or...

Page 15: ...3 Remove any obstructions Tighten or adjust shrouds 4 Tighten and isolate as needed 5 Call service agency D Temperature too high 1 Check power cord and circuit breaker 2 Temperature control set too high 3 Dirty condenser coil 4 Evaporator coil froze 5 Unknown 1 Plug in cord or reset breaker 2 Adjust control 3 Clean coil 4 Unplug unit defrost coil then adjust cold control to warmer position 5 Call ...

Page 16: ... RP SPT9902 RP SPT9903 RP SPT9904 RP SPT9901 RP SPT9902 Condensing Unit RF CON9803 RF CON0202 RF CON0107 RF CON0107 RF CON9803 RF CON0202 Compressor RF CON020 134 RF CON0104P N A N A RF CON020 134 RF CON0104P Evap Coil RF CO1120B RF CO1125 RF CO1127 RF CO1135 RF CO1120B RF CO1125 Evap Motor EL MTR0230 EL MTR0230 EL MTR0230 EL MTR0230 EL MTR0230 EL MTR0230 Fan Bracket RP BRK1050 RP BRK1050 RP BRK10...

Reviews: