background image

 

   

 

 

 

MSR112 

Magnetic Stripe Card Reader 

RS232 Interface 

Programmer’s Manual 

 

UIC EC/DC Document PM019 

Revision A 

23 May. 2002

 

 

 

Originator: Tammy Wang 

Document Owner: EC/DC

 

 

 

Taiwan, Factory 

USA, Office 

1

st

 F., No. 1, Lane 15, 

3811 Spinnaker Court 

Chih Chiang Street

 

Fremont, CA 94538-6573

 

Tu Cheng City,

 

U.S.A.

 

Taipei Hsien, Taiwan

 

 

Tel: 886-2-2268-7075 

Tel: (510) 438-6799

 

Fax: 886-2-2268-6327

 

Fax: (510) 438-6790

 

Email: 

[email protected]

 

Email: [email protected] 

URL: www.uniform.com.tw

 

URL: www.uicusa.com

 

 

 

Copyright 2002 Uniform Industrial Corporation 

All rights reserved.

Summary of Contents for MSR112 Series

Page 1: ...actory USA Office 1st F No 1 Lane 15 3811 Spinnaker Court Chih Chiang Street Fremont CA 94538 6573 Tu Cheng City U S A Taipei Hsien Taiwan Tel 886 2 2268 7075 Tel 510 438 6799 Fax 886 2 2268 6327 Fax...

Page 2: ...rference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructio...

Page 3: ...and understood prior to initial operation of the product For ease of installation and programming use we have addressed everything from its attractive features to its various configurations When desig...

Page 4: ...____________________________________________________________________ 10 Card Format ____________________________________________________________________ 10 Card Operation Speed _______________________...

Page 5: ..._________________________________________________ 15 ESC 1Bh Abort ______________________________________________________________ 15 9 39h Version Report_______________________________________________...

Page 6: ...al using a standard RS 232 interface Because of the transmitting protocol of MSR112 is more precise it is suitable for using in financial industry Function Self Test Whenever the reader experiences a...

Page 7: ...wiping without any command instruction however the reader still can accept commands from host to instruct reader sending out card data The reader can be configured to another one as host polled mode w...

Page 8: ...on 2 Configurations 2002 5 23 Page 8 Uniform Industrial Corp Proprietary and Confidential Total 18 pages Section 2 Configurations This section shows the dimensions and accessories for the MSR112 Dimen...

Page 9: ...ges Accessories of MSR112 The following accessories should be enclosed in your package 1 Interface cable DB9 male connector 1 5M 2 Programmer s manual or simple manual Installation 1 Turn OFF power to...

Page 10: ...ss 0 76 mm 0 08 mm Card Format Track 1 3 210 bpi Track 2 75 bpi Card Operation Speed Table 3 1 Card Operation Speed Test Card Speed IPS ISO standard card 5 55 Jitter 5 50 Low Amplitude 5 50 Note Jitte...

Page 11: ...ges Height 28mm Weight 208g Magnetic Head Life 500K Min 1M optional Electrical Specifications Power Required 3 3VDC Power Consumption 4 9mA in idle mode 5 9mA in operating mode Communication Standard...

Page 12: ...dy 1 DTR 6 DSR Reserved 2 DSR 8 CTS Reserved 3 CTS 3 TxD Serial data to host 4 TxD 7 RTS Request to Send 5 RTS 2 RxD Serial data from host 6 RxD SHIELD 7 SHIELD 5 GND 8 GND Communication Synchronizati...

Page 13: ...Remarks SS START SENTINEL TRACK1 ISO DMV AAMVA TRACK2 ISO DMV AAMVA TRACK3 ISO AAMVA CA old DMV Note TK3 SS can be replaced to for ISO for AAMVA and for CA old DMV while SS is enable ES END SENTINEL...

Page 14: ...mand that will be accepted for execution is Abort ESC Q 51h Transmit Standard Data Track 1 R 52h Transmit Standard Data Track 2 S 53h Transmit Standard Data Track 3 Comments 1 Process data in the read...

Page 15: ...rt Comments 1 Abort command is issued after the reader has responded to command P Reader would be waiting for card read 2 No response to Abort command if the reader just power on and no command is rec...

Page 16: ...idential Total 18 pages Response Reader to Host 5Eh ACK Comments Last command has been completed without an error condition and ready for the next command 21h Invalid Command Comments The command is n...

Page 17: ...r to transmission format in section 3 for details ESx 45h 53h x ES Enable Disable x E 45h enable or D 44h disable Note ES stands for End Sentinel refer to transmission format in section 3 for details...

Page 18: ...read error x E or F 4Eh or 4F enable or D 44h disable no data is output Default setting is E Please refer to transmission format in section 3 for details STx 53h 54h x STX Enable Disable x E 45h enabl...

Reviews: