background image

 
 
 
 

Waterproof Scale 

Technical Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for s29 series

Page 1: ...Waterproof Scale Technical Manual ...

Page 2: ...cale com Copyright by Taiwan Scale Mfg Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Taiwan scale Taiwan Scale reserves the right to make changes to the technology features specifications and design of the equipment without notice All information contained within this publication was to the best of ...

Page 3: ...Manual 3 CONTENTS 1 PRECAUTIONS 4 2 INSTALLATION 5 3 PARTS DESCRIPTION 6 4 OPERATION 8 5 PARAMETER 9 6 CALIBRATION 10 7 ERROR DISPLAY 11 8 DRAWING 12 PARTS NAME 12 9 SPECIFICATIONS 15 DIMENSION 15 LOAD CELL SPECIFICATION 16 ...

Page 4: ...suitable tables The tables or floor must be rigid and not vibrate Do not place near vibrating machinery Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Do not mix the type of batteries Replace all the batteries at the same time Only use original S29 adaptor other could cause damage to the scale When the scale is used with an adaptor...

Page 5: ...ert the adaptor pin to jack Adaptor simply plug into the mains power The scale no needs to be turned on The battery should be charged for 12 hours for full capacity Left side of the display there is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be recharged If the LED is green the battery has a full charge If it is red th...

Page 6: ...S29 Series Technical Manual 6 3 PARTS DESCRIPTION Optional Dry and Rechargeable Battery Adaptor jack Sealing Ring Platform Leveling Feet Key board Spirit Level ...

Page 7: ...anual 7 Key Board Weight Display Zero Zeroing Display Stable Stable Display Net Net Weight Display Low Battery Lb kg Current Weighing Mode Keys Turns the scale power On Off Subtracts weight of container Sets display to Zero ...

Page 8: ...an set the display of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero 3 Tare The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed Load weight on the pan Press key Zero is displayed and tare is subtracted Remove weight from the platform Tared wei...

Page 9: ...it can choose menu block one by one Menu Description F1 cal Calibration F2 res 3 000 Set Resolution 6000 dual F3 cap 3 kg Set Scale Capacity 6 kg 15 kg 3 0 kg F4 inp Internal Counts F5 0ff Set automatic turn off the scale 3 min Scale will be auto off three minutes later 5 min Scale will be auto off five minutes later 15 min Scale will be auto off 15 minutes later off Auto off function disable Back...

Page 10: ...isplay will be shown Press display will be shown current calibration weight value If necessary press to change the value and keep the weight on the platform After stable indicator on press key to confirm Scale will be restart Incase display will show any error message or incorrect measurement repeat the calibration again F1C al unload 5 kg ...

Page 11: ... Key board error Check the keys and connecter Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Check the load cell and connecters Err 17 Tare out of range Remove the load and restart scale again ol Over range Remove the load Re calibrat...

Page 12: ...S29 Series Technical Manual 12 11 DRAWING ...

Page 13: ... SUS304 M4x16 18 Lower load cell bracket Aluminum 19 Seal Rubber 1 Silicone 20 Bottom Cover 1 ABS 21 Battery Box 1 ABS 22 Battery 4 Size D 23 Battery Box cover 1 ABS 24 Battery box cover fixer2 2 ABS 25 Round Pan 1 ABS 26 Film fix circle 1 1 SUS304 27 Film 1 Silicon 28 Pan Spacer 3 2 NBR 29 Star Screw 6 SUS304 M4x10 30 Spring Washer 24 SUS304 M4 31 Washer 22 SUS304 M4 32 Front Display Overlay 1 PC...

Page 14: ...S29 Series Technical Manual 14 46 Foot fixer 4 ABS 47 Foot 4 PVC 48 Washer 8 NBR 49 Washer cover 8 SUS304 ...

Page 15: ...6kg 15kg External Resolution 3000 6000 Dual Display 25mm LCD display with White back light Dimensions 230mm x 300mm x 190mm Keypad Three keys Operate Temperature 0 C 40 C 32 F 104 F Power Adaptor 9V 800mA Battery 6V 3 4 AH Internal Counts Up to 60000 Weight Dry battery cell 3 1kg Lead Acid 4 2 kg ...

Page 16: ...3 45kg Sensitivity 2 0 0 002mv v Excitation Voltage 15V IP Level IP67 Material Aluminum Cable 0 3 3m Φ 4mm Input Resistance 405Ω 5Ω Out put Resistance 350Ω 3Ω Temperature Range 40 C 80 C Safe overload 150 F S Ultimate overload 200 F S Error 0 02 F S Creep 30min 0 02 F S Zero Balance 1 F S ...

Reviews: