background image

MIU-1500 / CompuCount User’s Guide 

Page 1 

 

 

U

ser’s Guide 

 

MIU1500 / CompuCount 

Wireless  

Data Manager

 

Summary of Contents for MIU1500

Page 1: ...MIU 1500 CompuCount User s Guide Pa User s Guide MIU1500 CompuCount Wireless Data Manager ...

Page 2: ...ng the MIU s Name 7 Adding Sensors 7 Viewing Counts 8 MIU Setup Options 9 The Status Screen 9 Sensor Setup 10 The MIU Setup Screen 10 The Communications Setup Screen 11 Set Count Manager s Clock 11 Passwords 12 Reset Options 13 Export Options 14 Alternate Format 17 Status of Sensors 18 FTP Scripts 19 Common Software Tools 20 Appendix 20 Specifications 21 Resetting the MIU 1500 to Factory Defaults ...

Page 3: ...orts of counts by half hour hour day week and month The MIU 1500 also makes this same data available as text files downloadable using an FTP client program The MIU 1500 can manage up to 16 sensors It can hold data for those 16 sensors for 3 months at 30 minute intervals and for 1 5 years at day intervals Models The new MIU 1500 is designed to work in conjunction with the following Traf Sys Wireles...

Page 4: ...has been received and processed Connecting to PC A crossover cable is included with the MIU 1500 setup Plug the crossover cable into the Ethernet port on the back of your computer and plug the other end into the Ethernet port on the MIU 1500 The Ethernet Link light green light will turn on indicating a valid Ethernet physical connection Connecting to LAN Alternatively you can connect the Manager t...

Page 5: ... subnet mask With Windows 98 and ME you will need to restart the PC WINDOWS XP WIN 95 98 ME 2000 To change the IP settings on a computer running Windows XP select the following Control Panel if not already presented you will find it easier to Switch to Classic View Network Connections Right click on Local Area Connection or Network Bridge if installed and select Properties Highlight Internet Proto...

Page 6: ... An MS DOS window will appear Type Ping and the IP address you are trying to ping If you want to change your Manager s IP address to say 192 168 1 213 you would type Ping 192 168 1 213 and wait for a response If the result of the ping is Request timed out then there is no other device on that IP address and you can safely change the IP address of the MIU 1500 Once you know the IP address you want ...

Page 7: ...dy in its list Off means that the MIU 1500 will never add new sensors to its sensor table Adding Sensors The MIU 1500 Count Manager by default adds sensors to its configuration list when it receives a packet that has been transmitted in Service Mode You can send a transmission in service mode by pressing the Smart Switch on the receiver the unit with the LCD display you will need to press this swi...

Page 8: ...e earlier than the first sensor transmission the cell for that time period will display n a for not applicable Each configured sensor has a row in the table Directional counters show counts on two lines for Count A and Count B The total of all counts for all sensors for that time period will be displayed on the bottom row of the table and the right hand column For all time intervals greater than H...

Page 9: ...nsor the serial number of the sensor ID the number of seconds elapsed since the last transmission Age whether the last transmission was sent in service mode or not Srv and the data value of the last reading Last Reading The last reading is the accumulated count of the sensor since the sensor started or since the last reset If the transmission was sent in service mode there will be an X in the Srv ...

Page 10: ...umber with care The MIU Setup Screen The setup screen allows you to set some parameters for the MIU 1500 You can change the name of the MIU 1500 Note the Manager Name is also used as the Login User Name when passwords have been set up Sensor Offline Time allows you can set the amount of time that can elapse between transmissions from one sensor before the sensor is declared offline You can set the...

Page 11: ...at the file cannot be found If you check the box that says Revert back to previous settings if no connection in 5 minutes then the program will try to update the Manager s IP address If it cannot make a connection within 5 minutes thereafter it will reset the IP address to the previous settings Set Count Manager s Clock You will need to make sure the Manager s clock is set correctly so that it can...

Page 12: ...etting the Report Password then viewing of reports is not restricted When you enter a password the characters will be masked with asterisks You type cat and the box will show It is very important that you remember your password Click Submit to establish password protection in the MIU 1500 After passwords are established you will encounter a screen requesting a password when attempting to perform a...

Page 13: ...nsor counts to zero Reset Counts delete all the sensors from MIU 1500 s setup table Delete All Sensors or reset the People MIU 1500 to factory settings Reset People MIU 1500 Resetting the MIU 1500 to factory settings will reset the IP address back to the default 192 168 1 55 The browser will not redirect itself and you will need to re enter the IP address into the Address bar ...

Page 14: ...last 7 full days until the present time counter per 30 minutes Counts for the last 31 full days until the present time counter per 30 minutes All Counts for the day Log counts per day Alternate Format Counts for the last full day until the present time counter per 30 minutes Counts for the last 7 full days until the present time counter per 30 minutes Counts for the last 31 full days until the pre...

Page 15: ... the last setup change report start the time and date of when the report starts report finish the time and date of when the report finishes Sample record 0 01 20 03 14 36 02 Sample PC 00 90 C2 C1 0F D9 2 01 20 03 13 10 17 01 17 03 00 00 00 01 20 03 14 36 01 Sensor Names 1 date time sensor name1 sensor namen date date that the report was generated time time that the report was generated sensor name...

Page 16: ...le record 7 01 17 03 00 00 00 127 115 Sensor Current Interval A Counts 8 date time countA1 countAn date date of the current interval This is a partial total for the interval as the current interval has not been completed yet time time of the current interval This is a partial total for the interval as the current interval has not been completed yet countA count for the current interval for the fir...

Page 17: ...ader that has titles for every column The following is an example Type Manager Name MAC Sensor Name Serial No Sensor Type Start Time End Time Count A Count B Data Record Type type of record 1 record contains counts for the full period 5 record contains counts for a partial period the current period which is incomplete Sever Name name given to the Manager MAC serial number of the Manager the ethern...

Page 18: ...rd Manager Name name given to the MIU 1500 MAC serial number of the Manager the ethernet MAC address Sensor Name name given to the sensor Serial No 16 character serial number of the sensor Sensor Type 1 Traf Sys People counter 2 Directional Counter Time time when the report was generated Count A accumulated count since the counter started or was reset Count B accumulated count since the counter st...

Page 19: ...vice at 192 168 1 55 Create a new text file with the contents below and save it as download bat FTP Script File The example below shows the commands you would use to create a ftp script file This script will login to the ftp interface of the MIU 1500 and download the RECPERALL txt file to the current directory Make sure you specify the ftp user name and password in the script to connect successful...

Page 20: ...and set up the MIU 1500 FTP command line utility that allows you download the report files Third party FTP Clients commercial and shareware FTP client programs used to download the report files Ping simple program to test the TCP IP connection Telnet simple program to send commands and see responses via TCP IP Note MIU 1500 uses port 1000 as default Winipcfg utility that shows the computer s IP ad...

Page 21: ...rent 250 milliamps Receiver Frequency 418 422 or 900 MHz or 2 4 GHz Ethernet 10BaseT 10 MHz 1 2 MHz effective rate Serial Port 19200 baud no parity 8 data bits 1 stop bit Battery 3 Volt Lithium CR2032 Backup of the SRAM real time clock 6 years without power 30 Minute Log 3 months Day Log 1 year 7 months Number of Sensors 16 ...

Page 22: ...can use to reset the memory back to the factory defaults You should use a paperclip to reach the reset button from the outside of the case Depending on the version of your MIU 1500 the reset switch can be located in different locations on your MIU 1500 The reset switch will be a small hole just large enough for a paperclip located near the antenna Here are some photo examples Figure 1 Figure 2 ...

Page 23: ... paperclip inserted you should be able to depress a button inside the case Hold the button down with the paperclip while plugging in the power adapter to the MIU 1500 When you plug in the power adapter the red Power indicator should flash on and off If the power indicator does not flash on and off remove the power adapter and make sure you are depressing the reset button Release the button and the...

Page 24: ...within this time IP Address 32 bit address usually represented as a series of 4 numbers that uniquely identifies a device that is using the TCP IP protocol ISP Internet Service Provider provides the means to interfacing to the Internet MAC The MAC address is permanently part of the MIU 1500 cannot be changed and is unique for all Ethernet interfaces Ping TCP IP diagnostic utility used to determine...

Reviews: