background image

I N S T A L L A T I O N   I N S T R U C T I O N S

FCI

PACI

Interactive Flat Panel Upgrade Kits

Spanish Product Description
German Product Description

 Portuguese Product Description

 Italian Product Description

Dutch Product Description

French Product Description

FCI / PACI

Summary of Contents for CHIEF FCI

Page 1: ... U C T I O N S FCI PACI Interactive Flat Panel Upgrade Kits Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description FCI PACI ...

Page 2: ... follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are prope...

Page 3: ...Installation Instructions FCI PACI 3 DIMENSIONS FCI 140 COVERAGE ANGLE FOR BEST RESULTS SLIDE THE SENSOR OUT UNTIL THE CORNERS OF THE TV ARE WITHIN THE COVERAGE AREA 0 50 12 7 RECOMMENDED SPACING ...

Page 4: ...FCI PACI Installation Instructions 4 DIMENSIONS continued 14 00 355 7 140 SENSOR COVERAGE SLIDE SENSOR SO THAT CORNERS OF TV ARE INSIDE COVERAGE AREA LIKE SHOWN ABOVE 0 50 12 7 RECOMMENDED SPACING PACI ...

Page 5: ...Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar...

Page 6: ... 1 Quick start guide KF 1 Stylus wrist strap kit KG 1 Interactive USB cable D 1 FCI 3 5 extension E 2 Interactive bar assembly J 1 3 16 ClickConnect Interactive Hardware Kit PACI Only A 2 10 24 x 3 8 B 2 10 C 1 1 8 FCI Only F 1 Sensor assembly G 2 5 16 x 5 8 H 1 1 8 D 1 PACI 3 5 extension F 1 Sensor assembly E 1 ClickConnect interactive assembly K 1 Chief Interactive Kit Both FCI PACI models PACI ...

Page 7: ...with the mount FCI PACI INSTALLATION IMPORTANT Determine depth thickness of flat panel TV If the TV is MORE than 3 in depth 76 2mm proceed to Step 1 If the TV is LESS than 3 in depth proceed to either Complete FCI Installation or Complete PACI Installation section as appropriate 1 Remove and save two button head cap screws and two washers from back of sensor assembly F See Figure 1 Figure 1 2 Remo...

Page 8: ...per extension See Figure 6 4 Tighten four button head cap screws on back of ClickConnect assembly E See Figure 6 Figure 6 5 Align ClickConnect assembly E with the mount aligning four mounting buttons on assembly with four mounting holes in mount See Figure 7 Figure 7 6 Lower ClickConnect assembly E into place listening for audible click to ensure recessed area of mounting buttons are properly seat...

Page 9: ...omputer USB port 3 Insert interactive software CD KC into computer and follow start up and operating instructions Minimum System Requirements for FCI PACI Windows System Compatible PC with Pentium II 400 MHz processor and 256 MB RAM Windows 2000 XP Server 2003 Vista or 7 30 MB available hard drive space Available USB port Macintosh System Power PC Intel 1 42 GHz processor and 1G RAM Mac OS X 10 5 ...

Page 10: ...I in both lateral and depth directions so that sensor assembly is as far as possible from the flat panel TV 2 Recalibrate the eBeam software a Right click on the eBeam icon on the system tray See Figure 12 b Select Calibrate Interactive Area and follow calibration instructions See Figure 12 Figure 12 Table 1 1 Recommended Sensor Locations Measurement Description Operational Range Recommended Depth...

Page 11: ...rid test will show distorted annotation lines See Figure 15 A passed grid test will show no broken or distorted annotation lines See Figure 15 Figure 15 5 If the grid test has failed gradually move the sensor assembly in 1 2 increments in both the depth and lateral extension ranges until the grid test is passed 6 If the interactive area is not responding precisely after the grid tests proceed to C...

Page 12: ...d the 3 numbers that appear in Hardware Diagnostics See Figure 16 6 Compare hardware diagnostics results to table below Example The hardware diagnostics numbers are 151 72 52 and indicate the sensor is near an ultrasonic device that causes interference See Figure 16 7 If interferences are detected separate FCI PACI from ultrasonic or IR interferences and try the set up again 8 If questions remain ...

Page 13: ...Installation Instructions FCI PACI 13 ...

Reviews: