Page 1: ...1 TCM2 Series Counting Scale Operation Manual V1 0 Contents Subject to Change without Notice ...

Page 2: ... Auto off time setting 12 9 Display A D inner code and working voltage 12 10 The details about RS232 communication 13 11 Date and time setting 14 12 ID setting 14 13 The second Platform Parameters setting 15 14 LCD test mode 15 15 The meaning of the special displayed character 16 16 Messages Symbols 17 17 Trouble Shooting 18 18 Packing List 19 19 Version History 19 ...

Page 3: ... 6lb 6kg 15lb 15kg 30lb UTP No 256 include unit tare weight piece weight Zero range Power on zero range calibration zero point 15 FS_kg Zero Key range power on zero 5 FS_kg Tare range 0 100 FS LCD display 0 73 18 digits 6 digit for weight 6 digit for piece weight 6 digit for pieces RS232 Built in Working temp 0 40 Power supply 1 12Vdc 500mA with positive center AC adaptor or 6Vdc4AH lead acid batt...

Page 4: ...4 2 Housing Interface 2 load cell connector DB9 Male 3 Rocker switch 4 AC power adapter input 5 RS232 connector DB9 Female 3 Faceplate 3 1 Front Display Panel ...

Page 5: ...indicator 3 3 6 Kg Lb Weight unit indicator 3 3 7 Kg Lb Piece weight indicator 3 3 8 PRINT Data output indicator 3 3 9 1 2 1 Main platform is used 2 Remote platform is used 3 3 10 CHG Battery charging indicator 3 3 11 AC AC adaptor in use indicator 3 3 12 PCS Enter number of pieces in sample 3 3 13 GROSS Gross weight is displaying 3 3 14 Net Net weight is displaying ...

Page 6: ...tare weight and its unit mode 4 12 N G Press down to toggle between net and gross 4 13 PRINT Output the data via RS232 port 4 14 1 2 To select remote platform or local platform 4 15 ON OFF Turn on the scale or turn off the scale 4 16 ON OFF 0 Press down more than three seconds to enter the calibration mode 4 17 ON OFF 1 Press down more than three seconds to setup the LCD s contrast and Backlight m...

Page 7: ...either gross or net weighing mode when scale reading is stable press Tare key to set the weight tare 5 3 3 Set keypad tare In the normal weighing mode input the tare weight to the weight window by numerical keys and press Tare key to confirm the setting of keypad tare weight or press RC UTP key to recall the stored keypad tare weight Use Exit key to exit this mode 5 3 5 Example 5 3 5 1 Weight tare...

Page 8: ...ECE WEIGHT window displays SPL PCS Sample Pieces and COUNT window displays the input quantity 5 8 2 Press numerical keys 0 9 and clear key to input the know quantity 5 8 3 Press ENTER key to save and record the input or press EXIT key to exit this mode and return back to the normal weighing and counting mode 5 8 4 Note The piece weight calculated by known quantities and weight must be over or equa...

Page 9: ...key after scale is stable 5 10 8 1 2 The COUNT window shows Inp Pcs means Input samples pieces PIECE WEIGHT window shows original pieces 5 10 8 1 3 If no need modifying the number just press ENTER key to confirm otherwise use numerical keys 0 9 and Clear key to input the known pieces Press ENTER key to confirm and go to the next step or press EXIT key to exit this mode and return back to the norma...

Page 10: ...elect tare weight is known or not Input TARE weight Select piece weight is known or unknown Input weight Put samples in to container to get samples net weight Input samples quantity Store weight unit tare weight and piece weight Known Unknown Press Enter when it s stable Known Unknown Next item next address Input quantity ...

Page 11: ...e the PIECE WEIGHT window displays LoAd1 this means it will be calibrated on standard weight for first point Place a standard weight more than 10 FS weight on the center of the scale platter when the scale is stable and the unit indicator stops flashing press ENTER to confirm or use EXIT key to exit the calibration mode 6 6 The display of the WEIGHT window remains the same the PIECE WEIGHT window ...

Page 12: ...w shows LCd CST LCD contrast and the COUNT window shows the contrast level x x 1 9 default is 5 Use the numerical keys to input the contrast level and press ENTER key for confirmation Press EXIT key to exit this mode and the scale will automatically reset 5 2 When WEIGHT window shows BLGT MD backlight mode and the COUNT window shows the backlight mode code x x 0 2 Use the numerical keys to input t...

Page 13: ... start bit 1stop bit 3 7E1 7 bits data 1 odd check 1 start bit 1stop bit And use Enter key to confirm the input and go to the next step or use EXIT key to exit this mode 10 5When the PIECE WEIGHT window shows Urt cFt communication format the COUNT window shows communication format xxx Use the numerical keys 0 1 2 3 to select the communication format 0 Non communication 1 When scale becomes stable ...

Page 14: ...After entering into this mode the WEIGHT window will display SEtuP the PIECE WEIGHT window will display dAtE date and the COUNT window will display the current date xx xx xx format YY MM DD 11 3 Use the numerical keys to input the date format YY MM DD use Enter key to confirm and go to the time setting mode 11 4 Then the weight window displays SetuP the PIECE WEIGHT displays timE time and the tota...

Page 15: ...n weight unit the COUNT window display the value of division 13 7Use numerical keys 0 1 key to input the value of the division d 0 0001 5 use ENTER key to confirm or EXIT to exit this mode 13 8The PIECE WEIGHT window displays 2nd n the division number under the 2nd weight unit the COUNT window display the number of division the division number under second unit the max is 1 25 Main n 13 9Use numer...

Page 16: ...16 15 The meaning of the special displayed character ASCII LCD LED Show ASCII LCD LED Show ASCII LCD LED Show 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z ...

Page 17: ...ecall memory data error data have not been set before recall it 16 13 CAP Data about capacity 16 14 UoL Data about voltage 16 15 Add Data about accumulation 16 16 PCwt Data about piece weight 16 17 St PCwt Set and store piece weight 16 18 Addr Memory unit address 16 19 Unit Weighing unit 16 20 Rc PCwt Recall the stored piece weight tare and its unit 16 21 Lo PCwt Below the Mini Piece Weight limit ...

Page 18: ...cted Replace load cell or ADC chip Service required Err31 Err10 EEPROM is damaged Replace EEPROM IC Err11 parameters are not set or not correctly set or setting lost Re set parameters do calibration Err12 Err20 Calibration error maybe input data or loaded weight is too small too big unstable un linear Input correct data load correct weight onto platform Service required Err40 UTP memory is not set...

Page 19: ...ded 1 4 Real Time Clock Battery CR2032 included 1 19 Version History VERSION DESCRIPTION DATE V1 0 Initial version 2013 05 20 Totalcomp Inc 99 Reagent Lane Fair Lawn NJ 07410 Phone 201 797 2718 Fax 201 797 2287 Toll Free Phone 800 631 0347 Toll Free Fax 888 797 2288 Website www totalcomp com ...