REV 0

CODE: 13100926

OWNER’S

MANUAL

RECEIPT SCALE

PC HSP Series

BEFORE OPERATING THIS SCALE, PLEASE READ THIS MANUAL THOROUGHLY

Содержание PC HSP Series

Страница 1: ...REV 0 CODE 13100926 OWNER S MANUAL RECEIPT SCALE PC HSP Series BEFORE OPERATING THIS SCALE PLEASE READ THIS MANUAL THOROUGHLY ...

Страница 2: ...unction How to store prices in the scale s memory How to load prices from the scale s memory How to set date and time Show sales Due balance Rechargeable battery Battery duration Serial connection with PC Important messages displayed About the printer Print speed Durability How to open the cover group How to load paper rolls how to close cover group correctly How to cut the paper Maintenance and c...

Страница 3: ...4 Use a VAC outlet exclusive for the scale avoiding overloads or voltage variations 5 Do not wash the scale using flow of water This can damage the electronic components For more information read Maintenance and cleaning section 6 Protect the scale from insects they can damage the electronic components Use only solid products against insects 7 Do not drop or hit the scale with the product to be we...

Страница 4: ...k and repair the scale 4 WARNING Do not open the scale Caution to reduce the risk of short circuit in your scale do not remove the cover or substitute any of the parts for others that are not original only authorized distributor Battery should be recharged for 10 hrs before using the scale for the first time IMPORTANT IMPORTANT WARNINGS PC HSP Series All tests and examples shown in this manual wer...

Страница 5: ... hit during transport which caused irreversible damage If so contact your authorized distributor It is also possible that the scale shows HELP when it is lit with a product on the plate in this case remove the weight from the scale turn it off and then on again 1 Unpack the scale and check that it is in good condition If you find any damage notify your authorized dealer immediately 2 Set the scale...

Страница 6: ...Y Liquid cristal display 6 ADJUSTABLE LEVELING BASES Loose or tight up them to adjust the scale 7 INPUT ADAPTER DC power supply connection located at the base of the scale 8 LEVEL INDICATOR Used as a scale s leveling reference 9 POWER SUPPLY 110 220 VAC to 9VDC Switching adapter included 10 SERIAL CONNECTOR Connect the scale with a PC using a RS232 cable 11 TURRET DISPLAY Turret with large digit d...

Страница 7: ...ny container s weight that you do not want to consider during a trade Is used to store prices data on the 99 scale s memory Press to load a price previously saved in the 99 scale s memory Press to activate the fixed price function Press to add a product to your sales ticket Receipt Scale Press to activate the change function ...

Страница 8: ...e price KEYBOARD LCD DISPLAY SCREEN 6 4 3 1 2 5 7 8 1 WEIGHT INDICATOR Shows product s weight 2 PRICE INDICATOR Indicates the product s price per pounds 3 FIXED PRICE INDICATOR Shows that the product s price would not be deleted when the product is removed from the scale Does not allow to modify the price only de activating the fixed price function will ...

Страница 9: ...ait for the screen to display zero Place the product to be weighted on the scale and the lb weight will be displayed on the WEIGHT indicator To enter a price per pound for a product type the product s price on the keypad It will appear on the PRICE indicator and the total sale will be shown at the TOTAL indicator When the product is weighted the scale will show the result automatically Weight x Co...

Страница 10: ...e How to finish a sales ticket without change To add prices up follow the next steps 1 Place a product to weight on the plate type the price and press M key for example a price of 2 20 and a weight of 1 50 lb 2 Remove the product 3 Place another product followed by the unit price and press M key again 4 To visualize the total sum without adding any price up press M key when in zero Price ADD UP 1 ...

Страница 11: ...e function is active the price will remain on the display although the weight is cleared from the scale To fix a price place the product on the scale s plate type the cost per lb of the product and press the P PACK key The P PACK indicator will be turned on To deactivate it clear the price by pressing the C key or press P PACK key again Fixed price function Total screen Sale ticket If the scale sh...

Страница 12: ...cale s memory 1 Type the price to save 2 Press STO key 3 Type in the memory slot to save from 00 99 4 Once you complete last steps you will hear a confirmation alarm How to load prices from the scale s memory Press the RCL key followed by the memory slot 00 99 An example sequence below If you have saved 26 60 in the memory slot 4 follow these steps to load 1 Press RCL key 2 Type 0 4 and the price ...

Страница 13: ...l as the year the month 1 to 12 will be set day depends on the month and year hour 0 to 23 and minute 0 to 59 To see the change made print a ticket How to set date and time You will be able to visualize the total sale accumulated in this way Turn on the scale and when the display shows the message enter the following code TARE M RCL RCL then a ticket will be printed showing the number of tickets a...

Страница 14: ...onsider tickets like the one in the following image you can print up to 700 tickets without connecting the AC DC adapter To restart the total accumulated sale and the ticket counter turn on the scale and when the display shows the message enter the following code TARE M RCL C then a ticket will be printed showing the number of tickets and the total accumulated sales after printing the data the tot...

Страница 15: ...e from our web site http www torrey cloud com downloads identify the PPT Torrey Software section and proceed to download System requirements Windows 7 or Windows 10 32 or 64 bits Receipt Scale IMPORTANT MESSAGES DISPLAYED LOW BATT If this message appears in intervals on display it indicates that the scale needs to be recharged Even with this advice the scale can continue working for 30 minutes If ...

Страница 16: ...o different situations 1 When the scale is turned on with an excess weight on the plate near half the scale s capacity To correct this situation remove the weight on the scale turn the scale off and then back on again 2 When the scale has been handled roughly and or hit NEGATIVE WEIGHT This message indicates a negative weight to fix this place back in its plate and press the 0 key or turn the scal...

Страница 17: ...e printer and close the door correctly ABOUT THE PRINTER The scale has 2 printing speeds The printing speed with battery is 10mm s The printing speed with AC DC adapter is 40 mm s Print speed PLS UNLOAD This message appears when the scale was turned on with a weight on the plate To quit this message remove the weight turn off the scale and then turn it on again The printer should not be in contact...

Страница 18: ...oup is released from its locking position To avoid damages to the lever do not use excessive force 18 PC HSP Series How to open the cover group Its important to put the paper roll in the correct position as indicated by the image otherway the printer will not print correctly How to load paper rolls ...

Страница 19: ...paper towards the rear bar from one side to other How to cut the paper How to close the cover group correctly Alternatively press on the middle area of the cover group near to the paper exit Do not close the cover group by pressing only on one side 19 Receipt Scale ...

Страница 20: ... under the plate or under the plate holder that could obstruct the adequate operation of your scale Periodically check the jack where the AC DC power supply in inserted to make sure it is in good condition that is check there are not signs of strokes or detachments Periodically check the AC DC power supply to make sure the ends are in good condition and that the cable is not twisted or tangled Reg...

Страница 21: ... DC power supply Low battery Connect the AC DC power supply and verify that the battery is been recharged If not replace the battery The scale shows different weights with the same product Material under the plate Check if exists materials under the platform If so remove them and check the operation again The word HELP appears in the display The scale was turned on with a weight over the plate Rem...

Страница 22: ... MAX TARE 80 lb MAX PRICE lb 999 99 MAX IMPORT 9999 99 OPER TEMP 14 F to 104 F PC 40L 80L HSP PC 40L 80L T HSP POWER SUPPLY INPUT 110 220VAC POWER SUPPLY OUTPUT 9VDC 2A BATTERY 6VDC 4 0A h MAX MAXIMUM CAPACITY MIN DIV MINIMUN DIVISION MAX TARE MAXIMUM TARE MAX PRICE lb MAXIMUM PRICE PER lb OPER TEMP OPERATING TEMPERATURE 14 37 5 62 14 181 14 055 5 62 14 181 14 055 16 93 22 PC HSP Series ...

Страница 23: ...as identification in case of loss or to future request Distributor_______________________________________________ Address ________________________________________________ Telephone number _______________________________________ Purchase date __________________________________________ Serial number ___________________________________________ We reserve the right to change any specification containe...

Страница 24: ...ELECTRONIC SCALE www torrey net ...