DIP3200A 32 Program IP to Analog Modulator

 

 
 

User Manual 

 
 

 

 

 

 

 

 

 

 

 

 

969 Horsham Road 

l

Horsham, Pennsylvania 19044 USA 

Phone: 215-675-2053   Fax:  215-675-7543 

l

[email protected]

Summary of Contents for DIP3200A

Page 1: ...DIP3200A 32 Program IP to Analog Modulator User Manual 969 Horsham Road l Horsham Pennsylvania 19044 USA l Phone 215 675 2053 Fax 215 675 7543 l info tonercable com...

Page 2: ...Directory Chapter 1 Product Overview 1 1 1 Key Features 1 1 2 Specifications 1 2 1 3 Appearance and Illustration 3 Chapter 2 Installation Guide 4 Chapter 3 Web NMS Management 5 12 Precautions 13...

Page 3: ...45 Ethernet front jack for Configuration and Web based Network management 1 2 Specifications Input Interface rate 2 GE RJ 45 ports for content ingest Max 840Mbps for each GE input Stream UDP UDP RTP...

Page 4: ...reo cross talk 55dB Residual carrier accuracy 1 TV standard NTSC or PAL B G Video signal to noise ratio 60dB Network Interface Management 1 x 100 Base T Ethernet RJ 45 Data 2 x 1000 Base T Ethernet RJ...

Page 5: ...Rear Panel Illustration 1 NMS network management port 2 Power Indicator 3 Grounding Earthing connection 4 AC Power Connection IEC Jack 5 Power switch 6 Content Input RJ 45 Jacks 2 7 RF output connect...

Page 6: ...onnection The power socket is located on the rear panel and the power switch is next to it 2 3 Content connection Use a standard Category 5 or higher Ethernet cable s to connect the DIP3200A to your s...

Page 7: ...the web browser and input the DIP3200A IP address in the browser s address bar and press Enter The Login box will appear Figure 1 Enter the default Username and Password Both the default Username and...

Page 8: ...ng the button to add them to the Output area Here you will see the details of the channel Figure 3 Configure Input Area and Output Area with buttons in Operation Area Instructions are as below To add...

Page 9: ...thin a 400 MHz wide bandwidth window The DIP3200A will not allow you to select a channel beyond the window so make sure your first channel and last channel are no more than 394 MHz apart Figure 4 Reme...

Page 10: ...25 185 75 62 451 25 455 75 112 721 25 725 75 9 187 25 191 75 63 457 25 461 75 113 727 25 731 75 10 193 25 197 75 64 463 25 467 75 114 733 25 737 75 11 199 25 203 75 65 469 25 473 75 115 739 25 743 75...

Page 11: ...monitor status of decoding It displays the interface as Figure 6 Figure 6 3 3 System 3 3 1 Network Click Network it displays the interface as Figure 7 where to set network parameters Figure 7 Set dat...

Page 12: ...where you can change login username and password for the web interface Figure 8 3 3 3 Configuration Click Configuration it displays the screen as Figure 9 where to set your configurations for the DIP3...

Page 13: ...ck Firmware it displays the screen as Figure 10 where to update firmware for the device Figure 10 System Log Click Log it displays the screen as Figure 11 where to check the Log Figure 11 To select Ke...

Page 14: ...12 System Reboot Click Reboot it displays the screen as Figure 12 where to check the Reboot Figure 12...

Page 15: ...dusty environment such as a laundry Make sure the electrical outlet is the correct voltage Make sure all connections are tight and installed properly Make sure that there are not power issues If the p...