background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for INTEGRA EMS TL-6760

Page 1: ......

Page 2: ...tronic Inc Airport Building 125 503 41 Hradec Kralove Czech Republic Fax 420 49 548 23 94 E mail info tl elektronic com Web Site Address www tl elektronic com Please send your e mail address to customer tl elektronic com to receive the latest information about software upgrade Send your ideas to innovation tl elektronic com We will evaluate your suggestion and provide an update Windows is register...

Page 3: ...RS 8 EMS RANGE AND LIMITS 15 AVAILABLE LIMITS CONFIGURATION TABLE 16 EMS OTHER SETTING CALIBRATION 21 AIRCRAFT IDENTIFICATION 22 TIME 22 DATE 23 FUEL FLOW 24 FUEL PRESSURE SET ZERO 25 FUEL CALIBRATION 26 WATER CHT TEMPERATURE LABEL 30 MAIN SWITCH CONTROL 31 EMS EXTERNAL DEVICES 32 CO GUARDIAN 32 EMS DATA SHARING 33 LANGUAGE 34 DEMO MODE 34 ...

Page 4: ...3 Introduction Record of Revision Record of revision Revision Revision Date Description ECO Insertion date By PrA 14 04 2013 Initial version Hovorka ...

Page 5: ...actual use When in actual use carefully compare indications from the INTEGRA to all available navigation sources including the information from other NAVAIDS visual sightings charts etc For safety always resolve any discrepancies before continuing navigation NOTE It is the pilot s responsibility for initial missed approach guidance in accordance with published procedure The unit may not provide co...

Page 6: ...5 EMS Setup Menu Introduction EMS Setup Menu ...

Page 7: ...ngine and sensor settings Menu EMS Setup Units Configuration Sensors Range and Limits Other Settings Calibration External Devices EMS Data Sharing Language Demo Mode Exit Menu UNITS You can choose between metric and imperial units or you can define your own unit settings Menu UNITS Metric Imperial UK Imperial US Custom Metric INTEGRA display units in metric system Bar C Pa litre Imperial US INTEGR...

Page 8: ... Indicator press of oil bar psi Indicator oil temperature Celsius Fahrenheit Internal air temperature Celsius Fahrenheit Outsider air temperature Celsius Fahrenheit Temperature of cylinders Celsius Fahrenheit Information about fuel fuel pressure bar kg cm2 psi Consumption fuel flow and fuel quantity Litre GAL Manifold air pressure mBar torr inHg ...

Page 9: ... menu you can properly set all connected sensors Menu CONFIGURATIONS SENSORS RPM MAP Rotor RPM Oil pressure Oil Temperature Water CHT Temperature Water Aux Temperature Left Total Tank Right Tank Fuel Pressure Fuel Flow EGT CHT number EGT CHT setting IAT OAT Voltage Current ...

Page 10: ...n engine block To enable displaying of this info see section Other Setting Calibration Water CHT Temperature Label Water Aux Temperature This sensor monitors water temperature To enable displaying of this info see section Other Setting Calibration Water CHT Temperature Label Left Total tank This sensor monitors fuel level in left tank Right tank This sensor monitors fuel level in right tank You ca...

Page 11: ...l Pressure This sensor monitors fuel pressure Fuel flow This sensor monitors Fuel Flow EGT CHT Number You can set the Cylinder Number to 2 4 or 6 IAT This sensor monitors internal air temperature OAT This sensor monitors outside air temperature ...

Page 12: ...is not used VoltageX Yes Select when you want to set label of Voltage 1 2 or 3 See next page for description Current You can choose where battery pump avionics etc you want gauge current monitoring Menu for Current is the same as for Voltage Menu Current Current1 Yes Current1 No Current1 Label Current2 Yes Current2 No Current2 Label Current3 Yes Current3 No Current3 Label CurrentX Yes Select when ...

Page 13: ...you get the required letter just press the knob and the underscore will skip on to the next letter Press Set to accept the new label Press Cancel to skip to previous menu Press Default to reset to default label For Voltage 1 is default label BATTERY for Voltage 2 PUMP for Voltage 3 AVIONICS Setting Voltage label ...

Page 14: ...you get the required letter just press the knob and the underscore will skip on to the next letter Press Set to accept the new label Press Cancel to skip to previous menu Press Default to reset to default label For Current 1 is default label BATTERY for Current 2 PUMP for Current 3 AVIONICS Setting Current label ...

Page 15: ...EGT or one of CHT Press the knob and discovers next menu Now select Input In this menu select desired thermocouple Now selected EGT or CHT is associated with this thermocouple You can do it the same way for every EGT and CHT CHT described here means Cylinder Head Temperature measured by thermocouples under spark plugs not in meaning used by ROTAX ...

Page 16: ... RPM Oil Pressure Oil Temperature Water CHT Temperature Water Aux Temperature Left Total tank Right tank Fuel pressure Fuel flow EGT CHT Voltage 1 Current 1 Voltage 2 Current 2 Voltage 3 Current 3 Range and Limits for Water Temperature and CHT are same This CHT refers to temperature measured on engine block ROTAX meaning of the word CHT refers to temperatures measured by thermocouples under spark ...

Page 17: ...o you need to decrease WARN at first and than you can set ALARM to lower value Available Limits Configuration Table You can set Indicator Range Min Alarm Min Warn Norm Warn Alarm RPM X X X X MAP X X X Rotor RPM X X X X X Oil Pressure X X X X X Oil Temperature X X X X X X Water CHT Temperature X X X X Water Aux Temperature X X X X Left tank Total Tank X X ...

Page 18: ...on Table You can set Indicator Range Min Alarm Min Warn Norm Warn Alarm Right tank X X Fuel pressure X X X X X Fuel flow X X EGT X X X CHT X X X Voltage 1 X X X X X Current 1 X X X X X Voltage 2 X X X X X Current 2 X X X X X Voltage 3 X X X X X Current 3 X X X X X ...

Page 19: ... and Limits Example of differences between set values Default values are defined RANGE MIN ALARM MIN WARN NORM WARN ALARM 3000 500 2700 2800 New values are defined RANGE MIN ALARM MIN WARN NORM WARN ALARM 5000 1000 3000 4000 ...

Page 20: ...er reaction As recommended by engine manufacturer Oil Temperature Warning Yellow indicator As recommended by engine manufacturer Maximum Oil Temp Consider setting this limit lower than the maximum to get early warning of abnormal oil temp As recommended by engine manufacturer Normal Oil Temperature Intended for troubleshooting Can also indicate reminder that the engine is not warm enough Set accor...

Page 21: ... for all engines but especially fuel injected engines Be sure to use it Account for max fuel flow rate at full takeoff set max 10 20 above max rate EGT Warning Maximum Exhaust Gas Temp Not all engines have published limits nor do all engines require a maximum EGT limit Set limit according to engine manufacturer recommendation or based on experience CHT Warning Warning Cylinder Head Temperature Oft...

Page 22: ...Menu OTHER SETTING CALIBRATION Aircraft Identification Time Date Backlight Control AUX Input Output Fuel Flow Fuel Press set zero pressure Fuel Calibration Set Unexhaustible Fuel RPM Setting Rotor RPM Setting Engine Time Threshold Water CHT Temperature Label Main Switch Control ...

Page 23: ...he knob and the underscore will skip on to the next letter Then press Set to enter the new value Press Cancel to skip previous menu Time You can set the time The underlined numbers you can change just rotate with the right hand knob If you get required time just press the knob and the underscore will skip on to the next number Then press Set to enter the new value Press Cancel to skip previous men...

Page 24: ...nge just rotate with the right hand knob If you get required time just press the knob and the underscore will skip on to the next number Then press Set to enter the date Please insert date in the form of DD MM YY or day month year Press Cancel to skip previous menu Cancel Set Position ...

Page 25: ...or should be changed only when the fuel tanks have been filled accurately on level ground After a few adjustments of the K Factor the fuel remaining and the fuel used as calculated by the INTEGRA should be within a few gallons or less of actual and should not need further adjustment Use the following fields as necessary to correct the K Factor The underlined numbers you can change by rotating the ...

Page 26: ... will show you average fuel flow The numbers of seconds you can change just rotate with the right hand knob If you get required number just press Set Press Cancel to skip previous menu NOTE Maximum displaying time which you can set is 10 seconds Fuel pressure set zero This is function for correction of variance between pressure sensors Set Position ...

Page 27: ...libration and press the knob Now is displayed label and you can choose number of steps merely rotate the knob When you have set number of steps press OK You can cancel this operation if you press the Cancel button NOTE You can set count of calibration steps in range from 3 to 15 NOTE If you want to change the capacity of the tank Enter to Setup Range and Limits Left Total Tank and set the RANGE If...

Page 28: ...displayed on the INTEGRA should be verified before the aircraft is released for flight Set unexhaustible fuel Your fuel tank may contain fuel that cannot be consumed In this step you may set the quantity of this fuel In first step you choose left or right tank Now the underlined number you can change just rotate with the right hand knob If you get the required number just press the knob and the un...

Page 29: ... the required number just press the knob and the underscore will skip on to the next number Press Set to enter the new value Press Cancel to skip previous menu NOTE If you are unable to install a sensor directly on your engine and the location of your sensor is affected by a reduction ratio It is then necessary to enter the correct reduction ratio If this function is not used then preset reduction...

Page 30: ...st press the knob and the underscore will skip on to the next number Press Set to enter the new value Press Cancel to skip previous menu Engine time Threshold The underlined number you can change by rotating the right hand knob If you get the required number just press the knob and the underscore will skip on to the next number Press Set to enter the new value Press Cancel to skip previous menu Ca...

Page 31: ...play WATER TEMPERATURE and or Cylinder Head Temperature ROTAX meaning of the word OR The CHT described here represents value measured on engine block with resistance sensor That s the meaning of CHT used by ROTAX Don t confuse this CHT with CHT measured by thermocouples under spark plug Water Temperature and CHT depiction as it is displayed on EMS screen ...

Page 32: ...Connected Connected Main Switch Control If you have Integra connected via external main switch set in this menu CONNECTED So you can power on or power off Integra via main switch If you have Integra connected directly to battery power choose NOT CONNECTED in this menu ...

Page 33: ...vices are devices which you can connect on port COM1 or COM2 CO Guardian You can connect and disconnect the external CO Guardian device on port COM 1or COM 2 CO guardian monitors the quantity of CO in the cockpit If quantity of CO exceeds the preset safe limit the INTEGRA will show you an alert message ...

Page 34: ... is connected to EMS INTEGRA The iFamily systems allows you to connect autopilot servos and remote compass NOTE See Integra iFamily Connection part and Explanation of Possible Connections in User Manual for more information Menu EMS Data Sharing Off Low Priority High Priority Off The Integra doesn t send EMS data to bus The Integra is not source of EMS data for other Integra units connected to bus...

Page 35: ...TEGRA Of course the opportunity for trying out features of other versions is also available in Integra Demo PC application which you could obtain from TL elektronic web site After you ll start up Demo Mode by selecting Demo On the Integra will be reading input data of sensors from loop in internal memory After time of loop is up loop will be automatically start up again Menu Demo Mode Demo ON Demo...

Page 36: ...tting complete settings of the Integra will be saved That includes the settings in standard screens e g set of Towing Menu Highway Baro Pressure Nav Source and in Setup Mode sensors setting units etc After count down of Reset Time reaches zero all settings that you ve made after the Save Setting option selection will be lost In other words settings will revert to state in moment that you ve select...

Page 37: ...36 Notes ...

Page 38: ......

Reviews: