background image

OWNER’S 

GUIDE

Electric and Gas Storage Water Heaters

Safety Information 
Owner’s Information 
Warranty

Models

Electric Storage Water Heaters: 

25THMS124P | 25THMS136 

50THMS124P | 50THMS136 

80THMB136 | 125THMB118 | 125THMB136 

160THMB124 | 160THMB136 | 250THMB136 

250THMB236 | 315THMB136 | 315THMB236 

315THMB248 | 400THMB136 | 400THMB248
N135THMB118 | N135THMB130 

N180THMB124 | N180THMB130

 

New Zealand only
Gas Storage Water Heaters: 

135THMB4N | 135THMB4P 

170THMB4N

Note – an ‘H’ at the end of the model 

number indicates that the water heater  

has been pre-fitted with a hard-water  

anode (not available in all models).

Summary of Contents for 125THMB118

Page 1: ...36 125THMB118 125THMB136 160THMB124 160THMB136 250THMB136 250THMB236 315THMB136 315THMB236 315THMB248 400THMB136 400THMB248 N135THMB118 N135THMB130 N180THMB124 N180THMB130 New Zealand only Gas Storage Water Heaters 135THMB4N 135THMB4P 170THMB4N Note an H at the end of the model number indicates that the water heater has been pre fitted with a hard water anode not available in all models ...

Page 2: ...E WHILE IT IS IN OPERATION DO NOT USE OR STORE FLAMMABLE MATERIALS IN OR NEAR THIS APPLIANCE DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE DO NOT operate the water heater with any panels or covers removed If the water heater is not used for two weeks or more a quantity of hydrogen which is highly flammable may accumulate inside the water heater tank To dissipate t...

Page 3: ...ustomer Service on 1300 412 612 Australia or 0800 729 389 New Zealand OVER TEMPERATURE ENERGY CUT OUT The operation of the over temperature energy cut out indicates a possibly dangerous situation Do NOT reset the over temperature energy cut out until the water heater has been serviced by a licensed tradesperson ELECTRICAL SAFETY This water heater is designed for single phase 240V a c supply only T...

Page 4: ... control valve is fitted and in working order WATER HEATER APPEARS TO BE LEAKING If your water heater is heating a large quantity of cold water condensation may form inside the water heater and drip down onto the burner This is NOT an indication the water heater is leaking but is the result of an efficient gas combustion process LIGHTING A GAS WATER HEATER Follow the Lighting Procedure steps on pa...

Page 5: ...ting their workmanship LOCATION The water heater should be located as close as possible to the most frequently used hot water outlet Ensure the compliance plate and associated warnings are clearly visible The water heater must be accessible without the use of a ladder or scaffold Adequate clearance must be available for service to the element thermostat relief valve and anode All models are equipp...

Page 6: ...er s Guide Electric and Gas Storage Water Heaters Specifications and materials may change without notice Effective for all Thermann Electric and Gas Storage Water Heaters manufactured and sold after 1st August 2020 ...

Page 7: ... Safety Information i Installation Requirements iv Water Supply and Connection 2 Lighting Gas Water Heaters 3 Filling Shut Down and Draining 4 System Maintenance 5 Considering a Service Call 6 Warranty 7 CONTENTS ...

Page 8: ...he water saturation index is greater than 0 40 an expansion control valve should be fitted If the index is greater than 0 80 the electrical heating element fitted to electric storage water heaters should be replaced with a low power density Incoloy heating element Please consult Customer Service on 1300 412 612 Australia or 0800 729 389 New Zealand for advice if required Hot Water Connection It is...

Page 9: ...ol knob depressed repeatedly press the igniter button for up to 40 seconds until the pilot flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its safety shutoff feature In this case wait sixty 60 seconds for the gas control valve to reset 6 Keep the control knob depressed for twenty 20 seconds after the pilot flame lights Use a mirror to ...

Page 10: ...er the lever gently and check it closes correctly Shutting Down a Gas Storage Water Heater 1 Remove the access cover and turn the control knob to the off position 2 Turn off the gas isolation valve Never turn off the gas supply without turning the control knob to the off position first 3 Turn off the cold water supply isolation valve 4 Replace the access cover Draining the Water Heater 1 Turn off ...

Page 11: ...s personally inspecting or servicing any part of your water heater is not recommended Annual Service Gas Storage Water Heaters This service should only be carried out by a licensed tradesperson The service should include the following Inspect and flush the PTR Valve and expansion control valve if installed Check the spark gap gas control valve and thermocouple Check and if necessary adjust the mai...

Page 12: ...ater for your requirements Sizing details are available from your local Reece branch Is there a leaking hot water pipe or dripping hot water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and have your plumber rectify any leaking pipe work Is the Pressure Temperature Relief Valve discharging too much water See below Continuous Trickle of Water from Pressure Tem...

Page 13: ...arrants against failure of the storage tank for a further period depending on the application and model 25 50L Electric Storage Tanks Six years for single family dwellings 80 400L Electric Storage Tanks Nine years for single family dwellings Gas Storage Tanks Six years for single family dwellings All Other Applications Two years During this period Dux will provide a replacement water heater free o...

Page 14: ... the water heater to and from an approved service agent or Dux office including any insurance associated with that transport or paying the travelling time of an approved service agent to and from the owners premises Commencement of Warranty The warranty period commences from the date of installation of the water heater Where proof of the date of installation is not available the warranty period co...

Page 15: ... the water heater payment of the reasonable costs of having the water heater repaired payment in respect of the reduced value of the water heater How to Make a Warranty Claim Warranty claims can be placed by completing the following steps Contact Customer Service on 1300 412 612 in Australia or 0800 729 389 in New Zealand Provide the serial number and model number of the water heater This can be f...

Page 16: ...028044 Rev H ...

Reviews: