background image

TD-1/11-099

 

 

 

TPL NET Network Module 

 

Installation and User Manual 

 

Issue Date: 25/06/2013 

IMPORTANT NOTIFICATIONS 

GENERAL 

Before  operating  devices,  read  carefully  this  manual  and 
save it to use later. 

Read all notifications and protections carefully that is written 
in this manual. Apply all management and using instructions 
respectively. 

Keep devices away from water and humidity. 

ENVIRONMENT CONDITIONS 

Do  not  operate  the  device  out  of  the  limits  which  are 
described below. 

 

Temperature: 

between 0

C and +65

 

Humidity: 

%95 at +40

SERVICE 

Do not attempt to repair device yourself. You may expose to 
electrical shock if you open the cover. 

In  case  of  any  malfunction  please  contact  your  dealer  or 
authorized  service.  Technical  response  to  the  device  must 
be performed by qualified service personnel. 

CONDITIONS REQUIRING TECHNICAL SERVICE 

Please  contact  your  authorized  service  or  dealer  in  case  of 
any malfunction or following cases happen. 

  If the power cord or plug is damaged, 

  If any fluid flows or something falls into the device, 

  If exposed to water or rain, 

  If device dropped or the cover damaged, 

  If  there  is  a  noticeable  performance  change  on  the 

device, 

  If  the  device  do  not  operating  due  to  management  and 

using instructions that are described in manual, 

  Since  wrong  operations  may  occur  new  malfunctions 

please contact the authorized service. 

SPARE COMPONENTS 

Be sure technician use original or equivalent component due 
to  risk  of  electrical  shock  of  another  malfunction  if  repair 
process will be realized by changing components. 

SAFETY CHECK 

In order to check if the device operating in secure conditions 
or not, request technical service from your authorized dealer. 

SPECIFICATIONS* 

TPLNET  module  provides  to  access  and  control  all  VAP 
series  alarm  panels  over  network,  internet,  and  intranet  via 
VAPMan software.  

 

Supported Velocities: 

10/100 Mbps 

Power Supply 

12 V DC, 50mA 

Username 

admin 

Password 

123456 

DHCP Support 

Yes 

Technical specifications may be changed without notification

 
 

MOUNTING 

1.  Turn down the energy of the panel completely, 
2.  Place  the  TPL  NET  card  coincide  with  the  holes  on  the 

printed circuit board carriers. 

3.  Stabilize  the  TPL  NET  card  to  the  panel  by  using  4 

screws that are inside the box and 4 mounting hole, 

4.  Plug one side of the connection cable of 4 which is ready 

inside  of  the  TPL  NET  box,  to  socket  on  the  TPL  NET 
board that is shown by blue arrow (2). 

5.  Plug one side of the connection cable of 6 which is ready 

inside  of  the  TPL  NET  box,  to  socket  on  the  TPLNET 
board that is shown by red arrow (1). 

6.  Plug  the  other  side  of  connection  cable  of  6  to  the 

expansion connector of 6 on the panel.  

7.  Plug the other side of connection cable of 4 to slot on the 

panel. (Slot location on electronic card may vary depends 
on type of the panel) 

8.  Insert  the  network  cable  (RJ-45  male  connector)  to  the 

socket on TPL NET which is shown by green arrow (3). 

9.  Turn on the energy of the panel again. 

 

 

 

LEARNING IP ADDRESS OF THE DEVICE 

As  you  can  learn  the  IP  address  of  the  device  via  DHCP 
server,  you can  also set by  the  program  CD  which  is  giving 
with  device  located  on  “TPLNET_FINDER.exe”.  When  this 
program  runs,  it  scans  automatically  the  modules  on  your 
program network and lists them. 

 

 

CONFIGURATION 

TPL NET module is set as DHCP ON in factory. It means if 
you have a DHCP server in your system, TPL NET takes its 
IP  automatically  and  starts  operating  without  any  setting. 
Green  light  on  the  RJ45  connector  shows  existence  of 
network  connection  (electrically),  yellow  light  shows 
existence of communication. 

     

Reviews: