background image

 

 

 

 
 

 

 

Uninterruptible Power Supply 

 

ERA LED 0.65 

ERA LED 0.85 

ERA LED 1.1 

 

User’s manual 

Summary of Contents for ERA LED 0.65

Page 1: ...Uninterruptible Power Supply ERA LED 0 65 ERA LED 0 85 ERA LED 1 1 User s manual ...

Page 2: ......

Page 3: ...ics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Battery Replacement 11 9 4 Operator Safety 12 10 Troubleshooting 12 Conformity to the European Directives 14 Product Disposal 14 Lead Batteries 14 Copyright 2012 TECNOWARE s r l All rights reserved All trademarks are property of their respective owners TECNOWARE s r l Via Montetrini 2E Loc Molino del Piano 50065 Pontassieve FI Italy ww...

Page 4: ... the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colour from the positive pole of the battery It is compulsory to ground the UPS according to Safety Standards The AC mains power supply socket used to power the UPS must have an...

Page 5: ...r a low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Linux etc Read this manual carefully before using the ERA LED it includes important safety warnings and useful advices for correct use and installation This manual is a guide that enables you to correctly in...

Page 6: ... packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send the UPS for maintenance purposes In case of transport damage notify the carrier and dealer immediately We recommend paying attention to the below points in order to choose a correct placement for your UPS The UPS is designed to operate in a protected environment e...

Page 7: ...and measurements Front panel shown below consists of two parts 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning in Normal Mode it flashes one time every 4 seconds in Battery mode and it flashes one time every second in Low Battery condition Figure 1 Front panel 2 1 ...

Page 8: ...t fuse electrical specification max current 5 A voltage 250 V 3 Grounded UPS Output receptacles IEC C13 type black colour to supply critical loads 4 Computer Interface USB connector it is the communication USB port In case of anomaly to the AC line black out the UPS Output receptacles black colour 3 continue supplying the correct power to all connected equipment 1 3 2 4 ...

Page 9: ...sure that all the devices connected to the UPS outputs are working correctly 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the UPS emits a brief acoustic signal every 10 seconds 8 Be sure that all the devices connected to the UPS outputs are working correctly and the UPS doesn t signal any sort of anomaly 9 Restore the AC Input line after few seconds t...

Page 10: ... 10 seconds and simultaneously the LINE BATTERY led flashes 6 3 Low Battery and Automatic Restart In Battery mode ERA LED indicates the Low Battery condition whenever the battery reaches a charge level allowing connected devices to operate for approximately one more minute During Low Battery condition the UPS emits an acoustic alarm signal every second and simultaneously the LINE BATTERY led flash...

Page 11: ...han rated value to the UPS see POWER specifications in the chapter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by emitting a continuous acoustic alarm During Fault condition the UPS doesn t supply Output power and so all the supplied devices are switched off 7 Communication Interface The UPS is fa...

Page 12: ...attery mode 5 Output Inverter Waveform Modified Sinewave Accepted Overload 130 Certifications CE Standards CEI EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 4 5 Ah 6 cells 12 Vdc 7 2 Ah 6 cells 12 Vdc 9 Ah 6 cells Backup Time typi...

Page 13: ...th Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are also other factors like the number of charge discharge cycles the discharge depth humidity and altitude The recommended environmental specifications for a correct use of batteries are li...

Page 14: ...Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safety Whenever the UPS is not responding anymore to original characteristics the UPS must be made non operative and every usage not authorised must be avoided After it will be necessary to refer to qualified tec...

Page 15: ...board failure Refer to Technical Service The UPS always function on Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains Input mains fuse is burnt Replace the fuse with another of the same type Black out conditions surge Over Voltage or Low Voltage Wait until the AC Input Line returns to normal conditions Electronic board...

Page 16: ... urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any parts can be damaging for the environment and for human health A correct waste disposal of products having the dustbin symbol marked by a cross help to avoid negative consequences to the environmen...

Page 17: ......

Page 18: ......

Page 19: ...TECNOWARE s r l www tecnoware com ...

Reviews: