PowerWalker VFI 1000-3000 TG/TB/TGS 

Quick Guide 

 

I.

 

Panel Description 

 

 

 

II.

 

Button 

Switch

 

Function

 

ON/Silence 
Button

 

By pressing the ON-Button continuously for more than 1 second the UPS system is 

turned on. 

By pressing this Button an acoustic alarm can be deactivated in the battery mode. 

By short touch this Button all acoustic alarms can be deactivated in all modes. 

By  pressing  this  Button  the  UPS  can  do  the  battery  test  in  the  Line  mode  or  ECO 

mode or CVCF mode. 

OFF 
Button

 

When  mains  power  is  normal,  the  UPS  system  switches  to  No  output  or  Bypass 

mode by pressing OFF-Button “ “, and the inverter is off. At this moment, if Bypass 

is enabled, then the output sockets are supplied with voltage via the bypass if the 

mains power is available. 

By pressing this Button an acoustic alarm can be deactivated in the bypass mode. 

Release the UPS from fault mode and EPO status. 

Select 
Button

 

The  output  voltage,  frequency,  Bypass  disable/enable  and  operating  mode  in  No 

output or Bypass mode, Battery Ah, Battery remain time display disable/enable and 

Charger  current  in  all  mode,  could  be  selected  by  pressing  Select-Button,  and 

confirmed by pressing Enter-Button.  

Enter 
Button

 

III.

 

Display 

Display 

Function 

 

It indicates input voltage/frequency value, which are displayed alternately. 

 

Summary of Contents for PowerWalker VFI 1000 TG

Page 1: ...to No output or Bypass mode by pressing OFF Button and the inverter is off At this moment if Bypass is enabled then the output sockets are supplied with voltage via the bypass if the mains power is available By pressing this Button an acoustic alarm can be deactivated in the bypass mode Release the UPS from fault mode and EPO status Select Button The output voltage frequency Bypass disable enable ...

Page 2: ...as some warnings It indicates the load level Every grid represents the level of 20 One grid would be displayed if the level is 0 20 It indicates the battery Power Every grid represents the Power of 20 IV Rear panel The graphic below applies to VFI 1000 TG and VFI 1000 TGS Models of different Power 2000 3000VA might have different location of components V Audible alarm function NO Status Alarm 1 Ba...

Page 3: ... can be turned to swap Line and Neutral EPO Emergency Power Off reset EPO first In case of other code please consider this as a fault Turn off the UPS and contact service VII Setting by LCD Module In bypass or no standby mode press Enter button to enter setting mode The middle section displays setting entry The right section display current value of the setting Press enter to edit the value the ri...

Page 4: ...2000 TG B 2000 TGS 3000 TG B 3000 TGS Input Single Phase 176 300 VAC or 80 285 VAC in bypass mode with 40 70Hz Output Single Phase 220 230 240V with 50 60Hz DC Voltage 24V 24V 48V 48V 72V 72V Power 9Ah 5Ah 120Ah 9Ah 5Ah 120Ah 9Ah 5Ah 120Ah Model No VFI 1000 TG TGB TGS VFI 2000 TG TGB TGS VFI 3000 TG TGB TGS Power rating 1kVA 0 9kW 2kVA 1 8kW 3kVA 2 7kW Ambient Temperature 0 o C to 40 o C Operating...

Reviews: