Metal Gasket

1. INTRODUCTION

SMA Hermetically-Sealed Panel Feedthrough Jack 
Receptacles 1053159-1, 1053181-1, 1053182-1, 
1053226-1, 1053227-1, 1053254-1, 1061372-1, and 
1089139-1 are designed to be mounted onto a panel 
using the following tools:

TOOL 

DESCRIPTION

PART NUMBER CROSS-REFERENCE

TE CONNECTIVITY

M/A-COM

Step Reamer

1055284-1

2098-0442-54

.250-36, UNS-2B 

Bottoming Tap

- -

2098-5618-54

Torque Tool

1055251-1

2098-0248-54

3/8-in. Open Wrench

- -

- -

† 

Commercially available

NOTE

i

Unless otherwise specified, dimensions in this 

instruction sheet are in metric units [with U.S. 

customary units in brackets].

Reasons for reissue of this instruction sheet are 
provided in Section 5, REVISION SUMMARY.

2. DESCRIPTION

The jack receptacle consists of a jack and metal 
gasket. See Figure 1.

3. ASSEMBLY PROCEDURE

DANGER

STOP

Follow safety precautions included with the tools 

used for assembly.

1. Refer to Figure 2, and drill a hole in the panel to 
the diameter shown. Using the step reamer, ream 
the hole to the depth shown. Using the bottoming 
tap, tap the thread to the depth shown. 

2. While holding the collet of the torque tool, turn the 
handle clockwise until it stops. Thread the jack into 
the tool until it bottoms inside the tool. Hand-tighten 
the jack. Refer to Figure 3.

NOTE

i

The torque tool is preset between 2.60 and 3.05 

Nm [23 and 27 in.-lb]. 

Recommended Panel Cutout

Note: Dimensions are in inches over millimeters.

Figure 2

Detail A

Detail B

Torque Tool

Collet (Ref)

Jack

Turn Handle

Clockwise

Figure 3

3. Install the metal gasket onto the jack. See 

Figure 4.

Metal Gasket

Figure 4