background image

ELECTRICAL WATER HEATER PANEL USER MANUAL

www.tanpera.com

Lcd Screen Control Panels

Summary of Contents for PROWATT

Page 1: ...ELECTRICAL WATER HEATER PANEL USER MANUAL www tanpera com Lcd Screen Control Panels ...

Page 2: ...Explains the transportation storage and warranty conditions of the control panels Read the user manual before operating your control panel Observe the safety information in particular All operations on the control panel must only be carried out by authorized persons in accordance with the information in the user manual No warranty is granted for repairs or alterations carried out by unauthorized p...

Page 3: ...uids and materials or pure flame away from the panel 7 The electrical connection of the panel must be connected to the main switch socket located inside the panel as shown in this manual Failure to do so may result in serious injury or death from electric shock 8 If the power cord is damaged it must be replaced by a new one suitable to the original by an authorized provider 9 Do not use damaged or...

Page 4: ...ges modifications to the control panel must only be made with the permission of the manufacturer If other parts are used on the control panels the manufacturer shall not be liable for the consequences of the changes 4 Special Safety Equipment and Recommendations on the Panel It may cause electric shock and death Improper intervention in the control panel may cause damage to it In the control panel...

Page 5: ...s damage or a missing part defect in the panel damage assessment report should be made to the transport company along with a written report to our company 7 3 Storage If the control panel is not to be installed immediately Do not store in humid environments Do not place weight on control boards Keep control panels where rain and water cannot enter them It should be noted that the panels may be dam...

Page 6: ...er before starting maintenance The control panel s electrical connections should be checked for loosening The control panel grounding line must be checked Check that there is no discoloration in the electrical cables due to wear puncture or heating 10 GENERAL INFORMATION The control panel that you have purchased is designed based on a microcontroller All control operations on the panel are done el...

Page 7: ...ving down the menu 5 Set button is used to enter the menu and save the changes made in the menu 6 The ESC key allows you to return to the previous menu and exit the current menu 7 1 Lights when the heater is switched on 8 2 Lights when the heater is switched on 9 Lights when there is an error in the system 10 3 Lights when the heater is switched on 11 4 Lights when the heater is switched on 12 Lig...

Page 8: ... SET button Max value starts to flash Max temperature value is entered with the help of Up Down keys Then Press SET button to save In this menu past events are displayed on the screen with the date and time of occurrence The last 20 events are displayed press the up arrow to view the next event This menu is used to restore the factory settings This menu is used to access the device memory with the...

Page 9: ...tings press the Up arrow key to select Current Settings and press the SET key When the current settings text is displayed if you want to see or change the values press SET button to enter the menu and the above screen is displayed Upper current text starts flashing Enter desired value with Up Down arrow and press SET button The lower current set starts to flash the same operation is done for the l...

Page 10: ...then goes into error status Temperature Hist The system that has failed due to high temperature must fall down to the set degree for a system restart Current Delay Current fault trip time setting When the upper or lower current exceeds the set value the motor stop time setting is set in seconds Vibration Time If the measured vibration value is above the set vibration value it waits for the set tim...

Page 11: ...shing which allows to select the day of the week Set the correct day from 7 days a week according to Monday as 1 and so forth then press the SET button After the date setting is finished the hour setting starts to flash and by setting the hour with the Up Down keys Press the SET button and the minutes start flashing After setting the minutes our date setting has been finished Press the SET button ...

Page 12: ...11 We reserve the right to make changes in technical information CONNECTION DIAGRAM ...

Page 13: ... TANKS PACKAGE TYPE DOMESTIC HOT WATER SYSTEMS BUFFER TANKS EXPANSION TANKS DEAERATORS DIRT SEPERATORS HYDROLIC SEPERATORS The great white heron can stand for a long time in the cold water as it can perform an effective heat exchange between the blood coming from the heart at 40 C and the blood returning from the feet at 1 C ...

Reviews: