TOWER PARTS KIT Installation Instructions
ETP-MT | ETP-MTE | ETP-MT/R
Page
1
of
4
Rev. 1/27/2017
Copyright 2017 Talkaphone
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talkaphone All rights reserved.
I.
Introduction
This manual is for the Blue Light Emergency Phone Tower (model
ETP-MT
), Radius Emergency Phone
Tower (model
ETP-MT/R
) and the ECO TOWER® Emergency Phone Tower (model
ETP-MTE
) installation
only. For instructions on installing the anchor bolts into the foundation, see the
TOWER ANCHOR BOLT
INSTALLATION INSTRUCTIONS
or
ETP-PDMK
INSTRUCTIONS
for Parking Deck Mounting Kits.
II.
Contents
Before beginning installation, make sure you have all the included components. Each
TOWER PARTS
kit
includes:
Qty. Part Number
Description
3
42941
10-24 x 3/4" Pin-In-Torx Pan head(TS-20 driver required)
2
42843
6-32 hex nut
1
68590
LED Panel Light (12-24V AC/DC - 120VAC)
1
ETP-EL
or
ETP-EL12/24
120VAC LED Blue Light
or
12/24V AC/DC LED Blue Light
III.
Installation
It is the installer’s obligation to ensure compliance with all national, regional,
and local regulations.
1.
After removing the tower from its shipping carton, install the LED Blue Light on top of the tower, feeding
the power cord and control wires through the top of the tower. If installing an
ETP-MT/R
tower series,
you will need to remove the cap plate atop the tower first. Fasten the LED Blue Light to the tower with
three (3) 10-24 pan head tamperproof screws. Replace the cap plate at the top, if used.
It is not
necessary to connect power lines at this point.
2.
Slide the LED Panel Light over the studs with the LEDs facing down. Tighten down using the two (2) 6-
32 hex nuts (provided). Be careful not to over tighten to avoid cracking the LED Panel Light.
3.
Install one 3/4”-10 hex nut and one washer (found in the
MT/R BOLT KIT
or
MT BOLT KIT
on each
anchor bolt 2.5-
3.5” above grade to top of washer. This will allow for a 1/2" air gap between the
foundation and the tower, which will allow airflow and prevent moisture problems. Verify that the nuts
are level (0° pitch).
–
See
Figure 1
–
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS
INVOLVED
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LES PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS