CONTROLLER MANUAL

TACOTHERM FRESH PETA

FRESH HOT WATER STATION 



Bedienungsanleitung

Frischwasserregler

ES 5941

Summary of Contents for TACOTHERM FRESH PETA ES 5941S

Page 1: ...ova Group AG Neunbrunnenstrasse 40 CH 8050 Zurich T 41 44 735 55 55 F 41 44 735 55 02 group taconova com 03 2017 Art Nr 212788 EA Nr 1243 en CONTROLLER MANUAL TACOTHERM FRESH PETA FRESH HOT WATER STAT...

Page 2: ...mode 14 7 2 INFO parameter overview 15 7 3 Querying temperatures and operating data 16 7 4 Values on information level 17 7 5 Parameters MENU overview 19 7 6 Enter password 20 7 7 Clock program 21 7...

Page 3: ...underground Never run device above or below limit values as listed under the technical data When it s expected that a safe operation isn t possible anymore then immediately shut down device For examp...

Page 4: ...48 7 Display LCD segment display Background lighting yes Operation 4 push buttons Ambient storage temperature 0 50 C 20 60 C max 85 non condensing eBUS x Capacity max 180 mA eBus feed 50 mA Bus line...

Page 5: ...it must first be dismounted 1 Lift up the front cover 2 Using a screwdriver lift the controller board out of the base see the figure at the right Make sure that before begin ning wiring work all line...

Page 6: ...nnected to the power supply in order to ensure its function at all times Upstream mains switches are there fore to be limited to emergency or main switches which are usually left in operation Before s...

Page 7: ...irculation pump is in operation it flashes slowly In the case of the switching valves the switching state is indicates AB A or AB B and the mixer position Open or Closed MENU kWh C K INFO 1 2 3 on off...

Page 8: ...the basic parameters 1 2 Example Change the language ENGLISH is active 3 To select DEUTSCH for example press the keys DEUTSCH will flash 4 Confirm the selection with the key You can find further infor...

Page 9: ...06 CIRC CALIBRATION see also 8 4 Calibrating circulation volumes page 29 After start up check the following The nominal temperature values are correctly set The temperatures actual values of the conne...

Page 10: ...ia the FRIWA pump with a speed controller which attempts to reach the set point on the TWW sensor and to hold it The TPV supply sensor for the plate heat exchanger optimizes the fresh water control si...

Page 11: ...EG01 THERM DIS INFECT TEMP and held for the LEG02 TEMP HOLDING TIME The circulation pump is active during the protection function Sensor side B7 V2 Voltage 5 V DC Ground GND TWW sensor B6 Flow sec V1...

Page 12: ...or providing the DHW nominal temperature value BAS01 TSET DHW plus minimal tempera ture loss STE14 MIN TDIFF HEAT EXCH on the heat exchanger The heat exchanger is held at this temperature Sensor side...

Page 13: ...eeded at the top storage tank sensor TO1 recharging is disa bled or the heat request is ended Recharg ing can be additionally restricted via a time program Sensor side TO1 sens Tank top B7 V2 Voltage...

Page 14: ...l mode is active 3 4 4 Test Manual mode is active Operating modes Standby AUS options DHW production still active Automatic mode The control functions are active according to the selected hydraulic ty...

Page 15: ...RI02 Tset tank top PRI03 Tank temp bottom PRI04 Supply temperature PRI05 Return temperature SEK SECONDARY SEK01 Temperature domestic hot water SEK02 Tset domestic hot water SEK03 Temperature cold wate...

Page 16: ...query the information in a sub menu press the key The first value will appear 5 One can navigate among the values with the key 5 6 6 The submenu selection is jumped to again by pressing the key If ano...

Page 17: ...tion into 9 other wise carry out measurements 5 8 and then eval uate 9 Calibration successful 10 Start 11 Error Flow despite pump being switched off 12 Error Flow rate fluctuations too great with the...

Page 18: ...setting STE07 TYPE FLOW SENSOR Attention For paddle switches no volumes are read in Here the value STE17 MAX TAPPING RATE is used and displayed SEK05 Temperature circulation Circulation temperature TB...

Page 19: ...e ZIR12 Circ time program ZIR13 Circ mode with consumpt ZIR14 Hysteresis circulation SCH LAYERING SCH00 Return layering SCH01 Diff return layering SCH02 TU sensor type SCH03 TPR sensor type SCH04 Fix...

Page 20: ...3 eBUS master number eBUS address of 2nd slave STN4 eBUS master number eBUS address of 3rd slave STN5 eBUS master number eBUS address of 4th slave KAS02 Sequence changeover KAS03 Station delay KAS04 C...

Page 21: ...E ON appears and set the desired time until the next change in the switching phase with If there are multiple switching phases repeat steps 4 and 5 alternately 5 6 6 The input of switching times is ex...

Page 22: ...e value of the adjuster can be changed with the keys The changed value is saved with the key Cancel the input or change to menu selection after the value has been set with the key By pressing once the...

Page 23: ...ion The DHW is first heated to the set legionella protection temperature according to the setting and maintained for the minimum holding time 0 No function 15 With pump WWC and TBZ 16 With pump WWC an...

Page 24: ...he middle part of the tank 5 40 K 25 05 105 SCH02 TU sensor type TU tank bottom sensor sensor type selection 0 NTC 5K 1 PT 1000 0 1 25 28 023 SCH03 TPR sensor type TPR PWT primary return sensor sensor...

Page 25: ...FRIWA PP 0 100 100 0 08 088 MAN02 Circ pump speed Manual control variable Circulation pump WWC 0 100 100 0 05 122 MAN03 Return layering Manual control variable Return layering valve VSR on off off 0 0...

Page 26: ...e entire cascade 0 Decentralized circulation pump each station has its own circulation pump settings and functions are local 1 Central circulation pump the circulation mode ther mal disinfection is se...

Page 27: ...ses for the time STE04 RUN TIME START SPEED at the starting point in order to quickly reach the set point The primary pump speed is regulated between the minimum and maximum speed limits The maximum s...

Page 28: ...rculation volume ZIR07 CIRCULATION FLOW RATE are defined If tapping is active and V is greater than STE15 MIN TAPPING RATE but less than ZIR08 MIN FL TAPPING SUPP circulation pump WWC is activated to...

Page 29: ...uccessful 10 Start 11 Error Flow despite pump being switched off 12 Error Flow rate fluctuation too great with the pump switched on Calibration To calibrate ZIR07 CIRCULATION FLOW RATE a maximum of 2...

Page 30: ...STE13 MIN CYCLING OFF TIME This way energy can be provided again on the primary side 8 6 2 Nominal value reduction Nominal value reduction This function is used when the heat source on the primary si...

Page 31: ...perature at the top storage tank sensor TO1 is less than the current set point T1Oset minus NAC03 Recharging hysteresis recharging is enabled or heat requested If the current set point is exceeded at...

Page 32: ...must be fallen below for a de fined time KAS03 DELAY TIME ATTENTION This should always be greater than the minimum speed of the primary pump STE03 MIN PRIM PUMP SPEED 8 9 1 Station operating mode Oper...

Page 33: ...uence change The automatic calibration mode ZIR06 2 leads to error massages and is not recommended SCH00 RETURN LAYERING Return layering can be activated and connected locally on each device or be cen...

Page 34: ...h stations 0 24 25 04 022 STN05 eBUS master number eBUS master numbers of the 5th stations 0 24 25 04 022 KAS02 Sequence changeover Interval sequence switching 0 8 2 06 020 KAS03 Station delay Delay t...

Page 35: ...at OFF Check fuses set external switch to ON Wiring defective Open the controller and check the wiring Status display STA01 STATUS 5 Fault 7 Warning Jump back into title screen to read off ERRO or IN...

Page 36: ...nsor plate heat exchanger outside of the measuring range Sensor short circuit interruption 9 2 Info message INFO Info display The controller checks the system status and signals an error This is a pla...

Page 37: ...695 100 339 10 9 950 105 294 15 7 855 110 255 20 6 245 115 223 25 5 000 120 195 30 4 029 130 150 40 2 663 140 118 9 3 2 Resistance values PT 1000 Temperature C Resistance PT1000 Temperature C Resistan...

Page 38: ...d PP Primary pump R RLS Return layering S Nominal value nominal Temperature specified by the operator or computed by the controller to which the heat con troller regulates the actual value T TBZ Tempe...

Page 39: ...n heat source temperature 29 N Nominal value reduction 29 O Operation 7 14 Q Querying temperatures and operating data 16 17 R Recharging primary 13 30 Resistance values NTC 5 kOhm 36 Resistance values...

Page 40: ...Manufacturing or Sales...

Reviews: